{"api_version":"1","generated_at":"2026-04-22T19:53:53+00:00","cve":"CVE-2023-37197","urls":{"html":"https://cve.report/CVE-2023-37197","api":"https://cve.report/api/cve/CVE-2023-37197.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-37197","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-37197"},"summary":{"title":"CVE-2023-37197","description":"A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the mass configuration settings of endpoints on DCE.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2023-07-12 07:15:00","updated_at":"2023-07-19 17:55:00"},"problem_types":["CWE-89"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf","refsource":"MISC","tags":[],"title":"","mime":"","httpstatus":"-1","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-37197","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-37197","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"37197","vulnerable":"1","versionEndIncluding":"7.9.3","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"struxureware_data_center_expert","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-37197","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"\n\n\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the mass configuration settings of endpoints on DCE. \n\n\n\n"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","cweId":"CWE-89"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Schneider Electric","product":{"product_data":[{"product_name":"StruxureWare Data Center Expert ","version":{"version_data":[{"version_affected":"=","version_value":"v7.9.3 and earlier"}]}}]}}]}},"references":{"reference_data":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf","refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"UNKNOWN"},"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}]}},"nvd":{"publishedDate":"2023-07-12 07:15:00","lastModifiedDate":"2023-07-19 17:55:00","problem_types":["CWE-89"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*","versionEndIncluding":"7.9.3","cpe_name":[]}]}]}},"legacy_mitre":{"record":null,"notes":[]}}}