{"api_version":"1","generated_at":"2026-04-25T05:42:27+00:00","cve":"CVE-2023-41255","urls":{"html":"https://cve.report/CVE-2023-41255","api":"https://cve.report/api/cve/CVE-2023-41255.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-41255","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-41255"},"summary":{"title":"CVE-2023-41255","description":"The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol  exposed on the network.","state":"PUBLIC","assigner":"psirt@bosch.com","published_at":"2023-10-25 18:17:00","updated_at":"2023-11-06 14:33:00"},"problem_types":["CWE-306"],"metrics":[],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","refsource":"MISC","tags":[],"title":"Multiple vulnerabilities on ctrlX HMI Web Panel - WR21 | Bosch PSIRT","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-41255","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-41255","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"41255","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2107","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41255","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2107_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41255","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2110","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41255","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2110_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41255","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2115","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41255","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2115_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-41255","ASSIGNER":"psirt@bosch.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol  exposed on the network."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-306 Missing Authentication for Critical Function","cweId":"CWE-306"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Rexroth","product":{"product_data":[{"product_name":"ctrlX HMI Web Panel - WR21 (WR2107)","version":{"version_data":[{"version_affected":"=","version_value":"all"}]}},{"product_name":"ctrlX HMI Web Panel - WR21 (WR2110)","version":{"version_data":[{"version_affected":"=","version_value":"all"}]}},{"product_name":"ctrlX HMI Web Panel - WR21 (WR2115)","version":{"version_data":[{"version_affected":"=","version_value":"all"}]}}]}}]}},"references":{"reference_data":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","refsource":"MISC","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"}]}},"nvd":{"publishedDate":"2023-10-25 18:17:00","lastModifiedDate":"2023-11-06 14:33:00","problem_types":["CWE-306"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}