{"api_version":"1","generated_at":"2026-04-25T03:39:48+00:00","cve":"CVE-2023-41372","urls":{"html":"https://cve.report/CVE-2023-41372","api":"https://cve.report/api/cve/CVE-2023-41372.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-41372","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-41372"},"summary":{"title":"CVE-2023-41372","description":"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair","state":"PUBLIC","assigner":"psirt@bosch.com","published_at":"2023-10-25 18:17:00","updated_at":"2023-11-06 15:05:00"},"problem_types":["CWE-798"],"metrics":[],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","refsource":"MISC","tags":[],"title":"Multiple vulnerabilities on ctrlX HMI Web Panel - WR21 | Bosch PSIRT","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-41372","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-41372","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"41372","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2107","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41372","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2107_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41372","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2110","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41372","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2110_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41372","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2115","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"41372","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"boschrexroth","cpe5":"ctrlx_hmi_web_panel_wr2115_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-41372","ASSIGNER":"psirt@bosch.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-798 Use of Hard-coded Credentials","cweId":"CWE-798"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Rexroth","product":{"product_data":[{"product_name":"ctrlX HMI Web Panel - WR21 (WR2107)","version":{"version_data":[{"version_affected":"=","version_value":"all"}]}},{"product_name":"ctrlX HMI Web Panel - WR21 (WR2110)","version":{"version_data":[{"version_affected":"=","version_value":"all"}]}},{"product_name":"ctrlX HMI Web Panel - WR21 (WR2115)","version":{"version_data":[{"version_affected":"=","version_value":"all"}]}}]}}]}},"references":{"reference_data":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","refsource":"MISC","name":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"}]},"impact":{"cvss":[{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"}]}},"nvd":{"publishedDate":"2023-10-25 18:17:00","lastModifiedDate":"2023-11-06 15:05:00","problem_types":["CWE-798"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}