{"api_version":"1","generated_at":"2026-07-23T11:02:04+00:00","cve":"CVE-2023-4346","urls":{"html":"https://cve.report/CVE-2023-4346","api":"https://cve.report/api/cve/CVE-2023-4346.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-4346","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-4346"},"summary":{"title":"CVE-2023-4346","description":"KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.","state":"PUBLISHED","assigner":"icscert","published_at":"2023-08-29 20:15:10","updated_at":"2026-07-16 05:16:16"},"problem_types":["CWE-645","CWE-645 CWE-645 Overly Restrictive Account Lockout Mechanism"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"references":[{"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-4346","name":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-4346","refsource":"134c704f-9b21-4f2e-91b3-4a467353bcc0","tags":["US Government Resource"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-236-01","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-236-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"KNX Protocol | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-4346","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-4346","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"KNX Association","product":"KNX Protocol Connection Authorization Option 1","version":"affected","platforms":[]}],"timeline":[{"source":"ADP","time":"2026-07-15T00:00:00.000Z","lang":"en","value":"CVE-2023-4346 added to CISA KEV"}],"solutions":[],"workarounds":[{"source":"CNA","title":"","value":"The KNX Association recommends users always set the BCU Key in every KNX Project that is already finished and will be commissioned in the future. Handover the BCU Key as part of the Project Documentation to the Building Owner.","time":"","lang":"en"}],"exploits":[],"credits":[{"source":"CNA","value":"Felix Eberstaller","lang":"en"},{"source":"CNA","value":"Limes Security","lang":"en"}],"nvd_cpes":[{"cve_year":"2023","cve_id":"4346","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"knx","cpe5":"connection_authorization","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":{"cve_year":"2023","cve_id":"4346","cve":"CVE-2023-4346","vendorProject":"KNX Association","product":"KNX Protocol Connection Authorization Option 1","vulnerabilityName":"KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability","dateAdded":"2026-07-15","shortDescription":"KNX Association KNX Protocol Connection Authorization Option 1 contains an overly restrictive account lockout mechanism vulnerability that could allow an attacker to purge all devices without additional security options enabled and set a BCU key to lock the device. ","requiredAction":"Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.","dueDate":"2026-07-29","knownRansomwareCampaignUse":"Unknown","notes":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-236-01 ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2023-4346","cwes":"CWE-645","catalogVersion":"2026.07.22","updated_at":"2026-07-22 20:07:15"},"epss":{"cve_year":"2023","cve_id":"4346","cve":"CVE-2023-4346","epss":"0.008550000","percentile":"0.545440000","score_date":"2026-07-22","updated_at":"2026-07-23 00:09:32"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-02T07:24:04.770Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["government-resource","x_transferred"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-236-01"}],"title":"CVE Program Container"},{"metrics":[{"other":{"content":{"id":"CVE-2023-4346","options":[{"Exploitation":"active"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-07-15T00:00:00+00:00","version":"2.0.3"},"type":"ssvc"}},{"other":{"content":{"dateAdded":"2026-07-15","reference":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-4346"},"type":"kev"}}],"providerMetadata":{"dateUpdated":"2026-07-16T03:55:23.364Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"references":[{"tags":["government-resource"],"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-4346"}],"timeline":[{"lang":"en","time":"2026-07-15T00:00:00.000Z","value":"CVE-2023-4346 added to CISA KEV"}],"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"KNX Protocol Connection Authorization Option 1","vendor":"KNX Association","versions":[{"status":"affected","version":"0"}]}],"credits":[{"lang":"en","type":"reporter","user":"00000000-0000-4000-9000-000000000000","value":"Felix Eberstaller"},{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Limes Security"}],"datePublic":"2023-08-24T16:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way. </span>\n\n"}],"value":"\nKNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way. \n\n"}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-645","description":"CWE-645 Overly Restrictive Account Lockout Mechanism","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2023-08-29T19:38:55.399Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-236-01"}],"source":{"discovery":"UNKNOWN"},"workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"\n\n<span style=\"background-color: rgb(255, 255, 255);\">The KNX Association recommends users always set the BCU Key in every KNX Project that is already finished and will be commissioned in the future. Handover the BCU Key as part of the Project Documentation to the Building Owner. </span>\n\n<br>"}],"value":"\nThe KNX Association recommends users always set the BCU Key in every KNX Project that is already finished and will be commissioned in the future. Handover the BCU Key as part of the Project Documentation to the Building Owner. \n\n\n"}],"x_generator":{"engine":"Vulnogram 0.1.0-dev"}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2023-4346","datePublished":"2023-08-29T19:38:55.399Z","dateReserved":"2023-08-14T22:14:58.101Z","dateUpdated":"2026-07-16T03:55:23.364Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2023-08-29 20:15:10","lastModifiedDate":"2026-07-16 05:16:16","problem_types":["CWE-645","CWE-645 CWE-645 Overly Restrictive Account Lockout Mechanism"],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-07-15T00:00:00+00:00","id":"CVE-2023-4346","options":[{"exploitation":"active"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:knx:connection_authorization:-:*:*:*:*:*:*:*","matchCriteriaId":"F328E1CB-8666-4D06-B2BC-9532454AF906"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2023","CveId":"4346","Ordinal":"1","Title":"CVE-2023-4346","CVE":"CVE-2023-4346","Year":"2023"},"notes":[{"CveYear":"2023","CveId":"4346","Ordinal":"1","NoteData":"KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.","Type":"Description","Title":"CVE-2023-4346"}]}}}