{"api_version":"1","generated_at":"2026-06-09T01:39:33+00:00","cve":"CVE-2023-4587","urls":{"html":"https://cve.report/CVE-2023-4587","api":"https://cve.report/api/cve/CVE-2023-4587.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-4587","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-4587"},"summary":{"title":"CVE-2023-4587","description":"** UNSUPPPORTED WHEN ASSIGNED ** An IDOR vulnerability has been found in ZKTeco ZEM800 product affecting version 6.60. This vulnerability allows a local attacker to obtain registered user backup files or device configuration files over a local network or through a VPN server.","state":"PUBLIC","assigner":"cve-coordination@incibe.es","published_at":"2023-09-04 12:15:00","updated_at":"2023-11-07 04:22:00"},"problem_types":["CWE-639"],"metrics":[],"references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso/insecure-direct-object-reference-zkteco-zem800","name":"https://www.incibe.es/en/incibe-cert/notices/aviso/insecure-direct-object-reference-zkteco-zem800","refsource":"MISC","tags":[],"title":"Insecure Direct Object Reference Zkteco Zem800 | INCIBE-CERT | INCIBE","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-4587","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-4587","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2023","cve_id":"4587","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"zkteco","cpe5":"zem800","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2023","cve_id":"4587","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"zkteco","cpe5":"zem800_firmware","cpe6":"6.60","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2023-4587","ASSIGNER":"cve-coordination@incibe.es","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"** UNSUPPPORTED WHEN ASSIGNED ** An IDOR vulnerability has been found in ZKTeco ZEM800 product affecting version 6.60. This vulnerability allows a local attacker to obtain registered user backup files or device configuration files over a local network or through a VPN server."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-639 Authorization Bypass Through User-Controlled Key","cweId":"CWE-639"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"ZKTeco ","product":{"product_data":[{"product_name":"ZEM800","version":{"version_data":[{"version_affected":"=","version_value":"6.60"}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso/insecure-direct-object-reference-zkteco-zem800","refsource":"MISC","name":"https://www.incibe.es/en/incibe-cert/notices/aviso/insecure-direct-object-reference-zkteco-zem800"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"EXTERNAL"},"solution":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The gama has been updated and it is recommended to upgrade to the latest version available."}],"value":"The gama has been updated and it is recommended to upgrade to the latest version available."}],"credits":[{"lang":"en","value":"David Utón Amaya (m3n0sd0n4ld)"}],"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"LOW","baseScore":8.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L","version":"3.1"}]}},"nvd":{"publishedDate":"2023-09-04 12:15:00","lastModifiedDate":"2023-11-07 04:22:00","problem_types":["CWE-639"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":1.8,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:zkteco:zem800_firmware:6.60:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:zkteco:zem800:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":null,"notes":[]}}}