{"api_version":"1","generated_at":"2026-04-23T12:21:25+00:00","cve":"CVE-2023-7339","urls":{"html":"https://cve.report/CVE-2023-7339","api":"https://cve.report/api/cve/CVE-2023-7339.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2023-7339","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2023-7339"},"summary":{"title":"Data collection for dowloading leads into buffer overflow","description":"Stack-based buffer overflow vulnerability in Softing Industrial Automation GmbH gateways allows overflow buffers.\nThis issue affects\npnGate: through 1.30\nepGate: through 1.30\nmbGate: through 1.30\nsmartLink HW-DP: through 1.30\nsmartLink HW-PN: through 1.01.","state":"PUBLISHED","assigner":"Softing","published_at":"2026-03-27 11:16:01","updated_at":"2026-03-30 13:26:29"},"problem_types":["CWE-121","CWE-121 CWE-121 Stack-based Buffer Overflow"],"metrics":[{"version":"3.1","source":"10de8ef9-5c89-4b17-8228-e97b74acf4bd","type":"Secondary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"references":[{"url":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.json","name":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.json","refsource":"134c704f-9b21-4f2e-91b3-4a467353bcc0","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.html","name":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.html","refsource":"134c704f-9b21-4f2e-91b3-4a467353bcc0","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2023-7339","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-7339","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Softing","product":"pnGate","version":"affected 1.30 custom","platforms":[]},{"source":"CNA","vendor":"Softing","product":"pnGate","version":"unaffected 1.34 custom","platforms":[]},{"source":"CNA","vendor":"Softing","product":"epGate","version":"affected 1.30 custom","platforms":[]},{"source":"CNA","vendor":"Softing","product":"mbGate","version":"affected 1.30 custom","platforms":[]},{"source":"CNA","vendor":"Softing","product":"smartLink HW-DP","version":"affected 1.30 custom","platforms":[]},{"source":"CNA","vendor":"Softing","product":"smartLink HW-DP","version":"unaffected 1.31 custom","platforms":[]},{"source":"CNA","vendor":"Softing","product":"smartLink HW-PN","version":"affected 1.01 custom","platforms":[]},{"source":"CNA","vendor":"Softing","product":"smartLink HW-PN","version":"unaffected 1.02 custom","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"pnGate: fixed with 1.34","time":"","lang":"en"},{"source":"CNA","title":"","value":"smartLink HW-DP: fixed with 1.31\nsmartLink HW-PN: fixed with 1.02","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2023","cve_id":"7339","cve":"CVE-2023-7339","epss":"0.000440000","percentile":"0.135890000","score_date":"2026-04-22","updated_at":"2026-04-23 00:03:17"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2023-7339","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-03-27T12:21:13.590182Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-03-27T12:21:25.031Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"references":[{"tags":["broken-link"],"url":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.html"},{"tags":["broken-link"],"url":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.json"}],"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"pnGate","vendor":"Softing","versions":[{"lessThanOrEqual":"1.30","status":"affected","version":"0","versionType":"custom"},{"status":"unaffected","version":"1.34","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"epGate","vendor":"Softing","versions":[{"lessThanOrEqual":"1.30","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"mbGate","vendor":"Softing","versions":[{"lessThanOrEqual":"1.30","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"smartLink HW-DP","vendor":"Softing","versions":[{"lessThanOrEqual":"1.30","status":"affected","version":"0","versionType":"custom"},{"status":"unaffected","version":"1.31","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"smartLink HW-PN","vendor":"Softing","versions":[{"lessThanOrEqual":"1.01","status":"affected","version":"0","versionType":"custom"},{"status":"unaffected","version":"1.02","versionType":"custom"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:softing:pngate:*:*:*:*:*:*:*:*","versionEndIncluding":"1.30","versionStartIncluding":"0","vulnerable":true},{"criteria":"cpe:2.3:a:softing:pngate:1.34:*:*:*:*:*:*:*","vulnerable":false}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:a:softing:epgate:*:*:*:*:*:*:*:*","versionEndIncluding":"1.30","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:a:softing:mbgate:*:*:*:*:*:*:*:*","versionEndIncluding":"1.30","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:a:softing:smartlink_hw-dp:*:*:*:*:*:*:*:*","versionEndIncluding":"1.30","versionStartIncluding":"0","vulnerable":true},{"criteria":"cpe:2.3:a:softing:smartlink_hw-dp:1.31:*:*:*:*:*:*:*","vulnerable":false}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:a:softing:smartlink_hw-pn:*:*:*:*:*:*:*:*","versionEndIncluding":"1.01","versionStartIncluding":"0","vulnerable":true},{"criteria":"cpe:2.3:a:softing:smartlink_hw-pn:1.02:*:*:*:*:*:*:*","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"OR"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Stack-based buffer overflow vulnerability in Softing Industrial Automation GmbH gateways allows overflow buffers.<br>This issue affects<br>pnGate: through 1.30<br>epGate: through 1.30<br>mbGate: through 1.30<br>smartLink HW-DP: through 1.30<br>smartLink HW-PN: through 1.01.</p>"}],"value":"Stack-based buffer overflow vulnerability in Softing Industrial Automation GmbH gateways allows overflow buffers.\nThis issue affects\npnGate: through 1.30\nepGate: through 1.30\nmbGate: through 1.30\nsmartLink HW-DP: through 1.30\nsmartLink HW-PN: through 1.01."}],"impacts":[{"capecId":"CAPEC-100","descriptions":[{"lang":"en","value":"CAPEC-100 Overflow Buffers"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","description":"CWE-121 Stack-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-03-27T10:53:07.778Z","orgId":"10de8ef9-5c89-4b17-8228-e97b74acf4bd","shortName":"Softing"},"references":[{"tags":["x_html"],"url":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.html"},{"tags":["x_json"],"url":"https://industrial.softing.com/fileadmin/psirt/downloads/2023/CVE-2023-7339.json"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>pnGate: fixed with 1.34<br></p>"}],"value":"pnGate: fixed with 1.34"},{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"smartLink HW-DP: fixed with 1.31<br>smartLink HW-PN: fixed with 1.02"}],"value":"smartLink HW-DP: fixed with 1.31\nsmartLink HW-PN: fixed with 1.02"}],"source":{"discovery":"INTERNAL"},"title":"Data collection for dowloading leads into buffer overflow","x_generator":{"engine":"Vulnogram 0.5.0"}}},"cveMetadata":{"assignerOrgId":"10de8ef9-5c89-4b17-8228-e97b74acf4bd","assignerShortName":"Softing","cveId":"CVE-2023-7339","datePublished":"2026-03-27T10:53:07.778Z","dateReserved":"2026-03-27T10:08:58.402Z","dateUpdated":"2026-03-27T12:21:25.031Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-03-27 11:16:01","lastModifiedDate":"2026-03-30 13:26:29","problem_types":["CWE-121","CWE-121 CWE-121 Stack-based Buffer Overflow"],"metrics":{"cvssMetricV31":[{"source":"10de8ef9-5c89-4b17-8228-e97b74acf4bd","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2023","CveId":"7339","Ordinal":"1","Title":"Data collection for dowloading leads into buffer overflow","CVE":"CVE-2023-7339","Year":"2023"},"notes":[{"CveYear":"2023","CveId":"7339","Ordinal":"1","NoteData":"Stack-based buffer overflow vulnerability in Softing Industrial Automation GmbH gateways allows overflow buffers.\nThis issue affects\npnGate: through 1.30\nepGate: through 1.30\nmbGate: through 1.30\nsmartLink HW-DP: through 1.30\nsmartLink HW-PN: through 1.01.","Type":"Description","Title":"Data collection for dowloading leads into buffer overflow"}]}}}