{"api_version":"1","generated_at":"2026-04-14T06:18:05+00:00","cve":"CVE-2024-1182","urls":{"html":"https://cve.report/CVE-2024-1182","api":"https://cve.report/api/cve/CVE-2024-1182.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2024-1182","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2024-1182"},"summary":{"title":"CVE-2024-1182","description":"Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature.","state":"PUBLISHED","assigner":"Mitsubishi","published_at":"2024-07-04 09:15:02","updated_at":"2026-04-08 14:16:23"},"problem_types":["CWE-427","CWE-427 CWE-427 Uncontrolled Search Path Element"],"metrics":[{"version":"3.1","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","score":"7","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf","name":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf","refsource":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://jvn.jp/vu/JVNVU98894016/","name":"https://jvn.jp/vu/JVNVU98894016/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2024-1182","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-1182","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Mitsubishi Electric Iconics Digital Solutions","product":"GENESIS64","version":"affected 10.97.3 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"GENESIS64","version":"affected 10.97.3 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Iconics Digital Solutions","product":"ICONICS Suite","version":"affected 10.97.3 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"ICONICS Suite","version":"affected 10.97.3 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Iconics Digital Solutions","product":"Hyper Historian","version":"affected 10.97.3 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"Hyper Historian","version":"affected 10.97.3 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Iconics Digital Solutions","product":"GENESIS32","version":"affected versions 9.7 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"GENESIS32","version":"affected versions 9.7 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MC Works64","version":"affected all versions","platforms":[]},{"source":"ADP","vendor":"iconics","product":"genesis64","version":"affected * custom","platforms":[]},{"source":"ADP","vendor":"mitsubishielectric","product":"mc_works64","version":"affected * custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-01T18:33:24.701Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"},{"tags":["government-resource","x_transferred"],"url":"https://jvn.jp/vu/JVNVU98894016/"},{"tags":["government-resource","x_transferred"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"}],"title":"CVE Program Container"},{"affected":[{"cpes":["cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"genesis64","vendor":"iconics","versions":[{"lessThanOrEqual":"*","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"mc_works64","vendor":"mitsubishielectric","versions":[{"lessThanOrEqual":"*","status":"affected","version":"0","versionType":"custom"}]}],"metrics":[{"other":{"content":{"id":"CVE-2024-1182","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2024-08-19T15:23:47.078975Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2024-08-19T15:25:49.496Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"GENESIS64","vendor":"Mitsubishi Electric Iconics Digital Solutions","versions":[{"status":"affected","version":"10.97.3 and prior"}]},{"defaultStatus":"unaffected","product":"GENESIS64","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"10.97.3 and prior"}]},{"defaultStatus":"unaffected","product":"ICONICS Suite","vendor":"Mitsubishi Electric Iconics Digital Solutions","versions":[{"status":"affected","version":"10.97.3 and prior"}]},{"defaultStatus":"unaffected","product":"ICONICS Suite","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"10.97.3 and prior"}]},{"defaultStatus":"unaffected","product":"Hyper Historian","vendor":"Mitsubishi Electric Iconics Digital Solutions","versions":[{"status":"affected","version":"10.97.3 and prior"}]},{"defaultStatus":"unaffected","product":"Hyper Historian","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"10.97.3 and prior"}]},{"defaultStatus":"unaffected","product":"GENESIS32","vendor":"Mitsubishi Electric Iconics Digital Solutions","versions":[{"status":"affected","version":"versions 9.7 and prior"}]},{"defaultStatus":"unaffected","product":"GENESIS32","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"versions 9.7 and prior"}]},{"defaultStatus":"unaffected","product":"MC Works64","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"all versions"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature."}],"value":"Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature."}],"impacts":[{"descriptions":[{"lang":"en","value":"Malicious Code Execution"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-427","description":"CWE-427 Uncontrolled Search Path Element","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-04-08T13:28:11.189Z","orgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","shortName":"Mitsubishi"},"references":[{"tags":["vendor-advisory"],"url":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"},{"tags":["government-resource"],"url":"https://jvn.jp/vu/JVNVU98894016/"},{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.1.0-dev"}}},"cveMetadata":{"assignerOrgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","assignerShortName":"Mitsubishi","cveId":"CVE-2024-1182","datePublished":"2024-07-04T08:53:41.217Z","dateReserved":"2024-02-02T00:20:48.886Z","dateUpdated":"2026-04-08T13:28:11.189Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2024-07-04 09:15:02","lastModifiedDate":"2026-04-08 14:16:23","problem_types":["CWE-427","CWE-427 CWE-427 Uncontrolled Search Path Element"],"metrics":{"cvssMetricV31":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2024","CveId":"1182","Ordinal":"1","Title":"CVE-2024-1182","CVE":"CVE-2024-1182","Year":"2024"},"notes":[{"CveYear":"2024","CveId":"1182","Ordinal":"1","NoteData":"Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows a local attacker to execute a malicious code by storing a specially crafted DLL in a specific folder when GENESIS64, ICONICS Suite, Hyper Historian, GENESIS32, and MC Works64 are installed with the Pager agent in the alarm multi-agent notification feature.","Type":"Description","Title":"CVE-2024-1182"}]}}}