{"api_version":"1","generated_at":"2026-06-03T19:01:11+00:00","cve":"CVE-2024-3264","urls":{"html":"https://cve.report/CVE-2024-3264","api":"https://cve.report/api/cve/CVE-2024-3264.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2024-3264","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2024-3264"},"summary":{"title":"Broken or Risky Cryptographic Algorithm in Mia Technology's Mia-Med Health Aplication","description":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\n\nThis issue affects Mia-Med Health Aplication: before 1.0.14.","state":"PUBLISHED","assigner":"TR-CERT","published_at":"2024-06-24 13:15:11","updated_at":"2026-06-03 16:16:21"},"problem_types":["CWE-327","CWE-327 CWE-327 Use of a Broken or Risky Cryptographic Algorithm"],"metrics":[{"version":"3.1","source":"iletisim@usom.gov.tr","type":"Secondary","score":"5.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"5.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0765","name":"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0765","refsource":"iletisim@usom.gov.tr","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.usom.gov.tr/bildirim/tr-24-0765","name":"https://www.usom.gov.tr/bildirim/tr-24-0765","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2024-3264","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-3264","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Mia Technology Inc.","product":"Mia-Med Health Aplication","version":"affected 1.0.14 custom","platforms":[]},{"source":"ADP","vendor":"miateknoloji","product":"mia-med","version":"affected 1.0.14 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Mustafa Anıl YILDIRIM","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"affected":[{"cpes":["cpe:2.3:a:miateknoloji:mia-med:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"mia-med","vendor":"miateknoloji","versions":[{"lessThan":"1.0.14","status":"affected","version":"0","versionType":"custom"}]}],"metrics":[{"other":{"content":{"id":"CVE-2024-3264","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2024-06-26T16:49:03.514353Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2024-06-26T18:56:37.905Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"},{"providerMetadata":{"dateUpdated":"2024-08-01T20:05:08.373Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_transferred"],"url":"https://www.usom.gov.tr/bildirim/tr-24-0765"}],"title":"CVE Program Container"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Mia-Med Health Aplication","vendor":"Mia Technology Inc.","versions":[{"lessThan":"1.0.14","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Mustafa Anıl YILDIRIM"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.<p>This issue affects Mia-Med Health Aplication: before 1.0.14.</p>"}],"value":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\n\nThis issue affects Mia-Med Health Aplication: before 1.0.14."}],"impacts":[{"capecId":"CAPEC-475","descriptions":[{"lang":"en","value":"CAPEC-475 Signature Spoofing by Improper Validation"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-327","description":"CWE-327 Use of a Broken or Risky Cryptographic Algorithm","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-06-03T14:16:51.216Z","orgId":"ca940d4e-fea4-4aa2-9a58-591a58b1ce21","shortName":"TR-CERT"},"references":[{"tags":["government-resource","broken-link"],"url":"https://www.usom.gov.tr/bildirim/tr-24-0765"},{"tags":["government-resource"],"url":"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0765"}],"source":{"advisory":"TR-24-0765","defect":["TR-24-0765"],"discovery":"UNKNOWN"},"title":"Broken or Risky Cryptographic Algorithm in Mia Technology's Mia-Med Health Aplication","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"ca940d4e-fea4-4aa2-9a58-591a58b1ce21","assignerShortName":"TR-CERT","cveId":"CVE-2024-3264","datePublished":"2024-06-24T12:45:13.204Z","dateReserved":"2024-04-03T12:54:07.773Z","dateUpdated":"2026-06-03T14:16:51.216Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2024-06-24 13:15:11","lastModifiedDate":"2026-06-03 16:16:21","problem_types":["CWE-327","CWE-327 CWE-327 Use of a Broken or Risky Cryptographic Algorithm"],"metrics":{"cvssMetricV31":[{"source":"iletisim@usom.gov.tr","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2024","CveId":"3264","Ordinal":"1","Title":"Broken or Risky Cryptographic Algorithm in Mia Technology's Mia-","CVE":"CVE-2024-3264","Year":"2024"},"notes":[{"CveYear":"2024","CveId":"3264","Ordinal":"1","NoteData":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\n\nThis issue affects Mia-Med Health Aplication: before 1.0.14.","Type":"Description","Title":"Broken or Risky Cryptographic Algorithm in Mia Technology's Mia-"}]}}}