{"api_version":"1","generated_at":"2026-10-25T10:08:21+00:00","cve":"CVE-2024-56840","urls":{"html":"https://cve.report/CVE-2024-56840","api":"https://cve.report/api/cve/CVE-2024-56840.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2024-56840","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2024-56840"},"summary":{"title":"CVE-2024-56840","description":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). Under certain conditions, IPsec may allow code injection in the affected device. An attacker could leverage this scenario to execute arbitrary code as root user.","state":"PUBLISHED","assigner":"siemens","published_at":"2025-12-09 16:17:29","updated_at":"2026-10-24 16:10:00"},"problem_types":["CWE-74","CWE-74 CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"7.5","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Secondary","score":"7.2","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"7.2","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","data":{"baseScore":7.2,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-912274.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-912274.html","refsource":"productcert@siemens.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2024-56840","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-56840","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","version":"affected V2.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX5000","version":"affected V2.17.0 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2024","cve_id":"56840","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"ruggedcom_rox_ii","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2024","cve_id":"56840","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"ruggedcom_rox_ii_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2024","cve_id":"56840","cve":"CVE-2024-56840","epss":"0.006370000","percentile":"0.499060000","score_date":"2026-10-23","updated_at":"2026-10-24 00:06:29"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2024-56840","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2025-12-09T14:27:32.481320Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-12-09T14:27:36.500Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000RE","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1400","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1500","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1501","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1510","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1511","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1512","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1524","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1536","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX5000","vendor":"Siemens","versions":[{"lessThan":"V2.17.0","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). Under certain conditions, IPsec may allow code injection in the affected device. An attacker could leverage this scenario to execute arbitrary code as root user."}],"metrics":[{"cvssV3_1":{"baseScore":7.2,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"}},{"cvssV4_0":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-74","description":"CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-01-13T09:43:55.345Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-912274.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2024-56840","datePublished":"2025-12-09T10:44:19.188Z","dateReserved":"2025-01-03T10:21:11.980Z","dateUpdated":"2026-01-13T09:43:55.345Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-12-09 16:17:29","lastModifiedDate":"2026-10-24 16:10:00","problem_types":["CWE-74","CWE-74 CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-12-09T14:27:32.481320Z","id":"CVE-2024-56840","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:ruggedcom_rox_ii_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.17.0","matchCriteriaId":"FA424C03-CB17-4397-A09E-E02A78F8176C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:ruggedcom_rox_ii:-:*:*:*:*:*:*:*","matchCriteriaId":"1EA04F52-40D0-4A4B-9767-265A26EFD98D"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2024","CveId":"56840","Ordinal":"1","Title":"CVE-2024-56840","CVE":"CVE-2024-56840","Year":"2024"},"notes":[{"CveYear":"2024","CveId":"56840","Ordinal":"1","NoteData":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). Under certain conditions, IPsec may allow code injection in the affected device. An attacker could leverage this scenario to execute arbitrary code as root user.","Type":"Description","Title":"CVE-2024-56840"}]}}}