{"api_version":"1","generated_at":"2026-10-21T10:17:02+00:00","cve":"CVE-2025-0665","urls":{"html":"https://cve.report/CVE-2025-0665","api":"https://cve.report/api/cve/CVE-2025-0665.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-0665","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-0665"},"summary":{"title":"eventfd double close","description":"libcurl would wrongly close the same eventfd file descriptor twice when taking\ndown a connection channel after having completed a threaded name resolve.","state":"PUBLISHED","assigner":"curl","published_at":"2025-02-05 10:15:22","updated_at":"2026-10-15 02:17:22"},"problem_types":["CWE-1341 Multiple Releases of Same Resource or Handle"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"7","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","data":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"7","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","baseScore":7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"HIGH"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://security.netapp.com/advisory/ntap-20250306-0007/","name":"https://security.netapp.com/advisory/ntap-20250306-0007/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://hackerone.com/reports/2954286","name":"https://hackerone.com/reports/2954286","refsource":"2499f714-1537-4658-8207-48ae4bb9eae9","tags":["Exploit","Issue Tracking","Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"http://www.openwall.com/lists/oss-security/2025/02/05/5","name":"http://www.openwall.com/lists/oss-security/2025/02/05/5","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://curl.se/docs/CVE-2025-0665.json","name":"https://curl.se/docs/CVE-2025-0665.json","refsource":"2499f714-1537-4658-8207-48ae4bb9eae9","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://curl.se/docs/CVE-2025-0665.html","name":"https://curl.se/docs/CVE-2025-0665.html","refsource":"2499f714-1537-4658-8207-48ae4bb9eae9","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"http://www.openwall.com/lists/oss-security/2025/02/05/2","name":"http://www.openwall.com/lists/oss-security/2025/02/05/2","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-0665","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-0665","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"curl","product":"curl","version":"affected 8.11.1 8.11.1 semver","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM RST2428P","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCH328","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCM324","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCM328","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCM332","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 12xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 8xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 12xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 8xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 12xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 8xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Christian Heusel","lang":"en"},{"source":"CNA","value":"Andy Pan","lang":"en"}],"nvd_cpes":[{"cve_year":"2025","cve_id":"665","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"haxx","cpe5":"curl","cpe6":"8.11.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"netapp","cpe5":"bootstrap_os","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"netapp","cpe5":"h300s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"netapp","cpe5":"h300s_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"netapp","cpe5":"h410c","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"netapp","cpe5":"h410c_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"netapp","cpe5":"h410s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"netapp","cpe5":"h410s_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"netapp","cpe5":"h500s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"netapp","cpe5":"h500s_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"netapp","cpe5":"h700s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"netapp","cpe5":"h700s_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"665","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"netapp","cpe5":"hci_compute_node","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2025-03-07T00:10:49.291Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"url":"http://www.openwall.com/lists/oss-security/2025/02/05/2"},{"url":"http://www.openwall.com/lists/oss-security/2025/02/05/5"},{"url":"https://security.netapp.com/advisory/ntap-20250306-0007/"}],"title":"CVE Program Container"},{"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","version":"3.1"}},{"other":{"content":{"id":"CVE-2025-0665","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-03-17T17:42:03.317434Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-03-17T17:42:06.679Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"},{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM RST2428P","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCH328","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCM324","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCM328","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCM332","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (230 V AC, 12xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (230 V AC, 8xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (24 V DC, 12xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (24 V DC, 8xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (2x230 V AC, 12xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (2x230 V AC, 8xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-10-15T01:01:54.492Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"curl","vendor":"curl","versions":[{"lessThanOrEqual":"8.11.1","status":"affected","version":"8.11.1","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Christian Heusel"},{"lang":"en","type":"remediation developer","value":"Andy Pan"}],"descriptions":[{"lang":"en","value":"libcurl would wrongly close the same eventfd file descriptor twice when taking\ndown a connection channel after having completed a threaded name resolve."}],"problemTypes":[{"descriptions":[{"description":"CWE-1341 Multiple Releases of Same Resource or Handle","lang":"en"}]}],"providerMetadata":{"dateUpdated":"2025-02-05T09:16:49.038Z","orgId":"2499f714-1537-4658-8207-48ae4bb9eae9","shortName":"curl"},"references":[{"name":"json","url":"https://curl.se/docs/CVE-2025-0665.json"},{"name":"www","url":"https://curl.se/docs/CVE-2025-0665.html"},{"name":"issue","url":"https://hackerone.com/reports/2954286"}],"title":"eventfd double close"}},"cveMetadata":{"assignerOrgId":"2499f714-1537-4658-8207-48ae4bb9eae9","assignerShortName":"curl","cveId":"CVE-2025-0665","datePublished":"2025-02-05T09:16:49.038Z","dateReserved":"2025-01-23T08:40:34.867Z","dateUpdated":"2026-10-15T01:01:54.492Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-02-05 10:15:22","lastModifiedDate":"2026-10-15 02:17:22","problem_types":["CWE-1341 Multiple Releases of Same Resource or Handle"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H","baseScore":7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":4.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-17T17:42:03.317434Z","id":"CVE-2025-0665","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:haxx:curl:8.11.1:*:*:*:*:*:*:*","matchCriteriaId":"AC5F2B81-22E8-4A24-B4AA-86FC581E95D9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*","matchCriteriaId":"95BA156C-C977-4F0C-8DFB-3FAE9CC8C02D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netapp:hci_compute_node:-:*:*:*:*:*:*:*","matchCriteriaId":"AD7447BC-F315-4298-A822-549942FC118B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"6770B6C3-732E-4E22-BF1C-2D2FD610061C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*","matchCriteriaId":"9F9C8C20-42EB-4AB5-BD97-212DEB070C43"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"234DEFE0-5CE5-4B0A-96B8-5D227CB8ED31"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*","matchCriteriaId":"CDDF61B7-EC5C-467C-B710-B89F502CD04F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"D0B4AD8A-F172-4558-AEC6-FF424BA2D912"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*","matchCriteriaId":"8497A4C9-8474-4A62-8331-3FE862ED4098"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"7FFF7106-ED78-49BA-9EC5-B889E3685D53"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*","matchCriteriaId":"E63D8B0F-006E-4801-BF9D-1C001BBFB4F9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"56409CEC-5A1E-4450-AA42-641E459CC2AF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*","matchCriteriaId":"B06F4839-D16A-4A61-9BB5-55B13F41E47F"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"665","Ordinal":"1","Title":"eventfd double close","CVE":"CVE-2025-0665","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"665","Ordinal":"1","NoteData":"libcurl would wrongly close the same eventfd file descriptor twice when taking\ndown a connection channel after having completed a threaded name resolve.","Type":"Description","Title":"eventfd double close"}]}}}