{"api_version":"1","generated_at":"2026-10-24T00:52:04+00:00","cve":"CVE-2025-11577","urls":{"html":"https://cve.report/CVE-2025-11577","api":"https://cve.report/api/cve/CVE-2025-11577.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-11577","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-11577"},"summary":{"title":"Clevo UEFI firmware exposed Boot Guard private keys, enabling potential abuse of the Boot Guard trust chain","description":"Clevo’s UEFI firmware update packages, including B10717.exe, inadvertently contained private signing keys used for Boot Guard and Boot Policy Manifest verification. The exposure of these keys could allow attackers to sign malicious firmware that appears trusted by affected systems, undermining the integrity of the early boot process.","state":"PUBLISHED","assigner":"certcc","published_at":"2025-10-14 16:15:36","updated_at":"2026-10-08 12:10:00"},"problem_types":["CWE-321 Use of Hard‑coded Cryptographic Key"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"7.6","severity":"HIGH","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"HIGH","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"7.6","severity":"HIGH","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","baseScore":7.6,"baseSeverity":"HIGH","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}}],"references":[{"url":"https://www.binarly.io/advisories/brly-2025-002","name":"https://www.binarly.io/advisories/brly-2025-002","refsource":"cret@cert.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.kb.cert.org/vuls/id/538470","name":"https://www.kb.cert.org/vuls/id/538470","refsource":"cret@cert.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-11577","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-11577","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Clevo","product":"Notebook System Firmware","version":"affected 1.07.07TRO1","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"11577","cve":"CVE-2025-11577","epss":"0.002610000","percentile":"0.169720000","score_date":"2026-10-23","updated_at":"2026-10-24 00:06:33"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"HIGH","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},{"other":{"content":{"id":"CVE-2025-11577","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2025-10-15T13:17:29.919651Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-10-15T13:17:44.736Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"Notebook System Firmware","vendor":"Clevo","versions":[{"status":"affected","version":"1.07.07TRO1"}]}],"descriptions":[{"lang":"en","value":"Clevo’s UEFI firmware update packages, including B10717.exe, inadvertently contained private signing keys used for Boot Guard and Boot Policy Manifest verification. The exposure of these keys could allow attackers to sign malicious firmware that appears trusted by affected systems, undermining the integrity of the early boot process."}],"problemTypes":[{"descriptions":[{"description":"CWE-321 Use of Hard‑coded Cryptographic Key","lang":"en"}]}],"providerMetadata":{"dateUpdated":"2025-10-14T15:34:09.651Z","orgId":"37e5125f-f79b-445b-8fad-9564f167944b","shortName":"certcc"},"references":[{"url":"https://www.binarly.io/advisories/brly-2025-002"},{"url":"https://www.kb.cert.org/vuls/id/538470"}],"source":{"discovery":"EXTERNAL"},"title":"Clevo UEFI firmware exposed Boot Guard private keys, enabling potential abuse of the Boot Guard trust chain","x_generator":{"engine":"VINCE 3.0.26","env":"prod","origin":"https://cveawg.mitre.org/api/cve/CVE-2025-11577"}}},"cveMetadata":{"assignerOrgId":"37e5125f-f79b-445b-8fad-9564f167944b","assignerShortName":"certcc","cveId":"CVE-2025-11577","datePublished":"2025-10-14T15:34:09.651Z","dateReserved":"2025-10-10T02:08:14.733Z","dateUpdated":"2025-10-15T13:17:44.736Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2025-10-14 16:15:36","lastModifiedDate":"2026-10-08 12:10:00","problem_types":["CWE-321 Use of Hard‑coded Cryptographic Key"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","baseScore":7.6,"baseSeverity":"HIGH","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.9,"impactScore":6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-10-15T13:17:29.919651Z","id":"CVE-2025-11577","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"11577","Ordinal":"1","Title":"Clevo UEFI firmware exposed Boot Guard private keys, enabling po","CVE":"CVE-2025-11577","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"11577","Ordinal":"1","NoteData":"Clevo’s UEFI firmware update packages, including B10717.exe, inadvertently contained private signing keys used for Boot Guard and Boot Policy Manifest verification. The exposure of these keys could allow attackers to sign malicious firmware that appears trusted by affected systems, undermining the integrity of the early boot process.","Type":"Description","Title":"Clevo UEFI firmware exposed Boot Guard private keys, enabling po"}]}}}