{"api_version":"1","generated_at":"2026-05-13T02:10:58+00:00","cve":"CVE-2025-13845","urls":{"html":"https://cve.report/CVE-2025-13845","api":"https://cve.report/api/cve/CVE-2025-13845.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-13845","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-13845"},"summary":{"title":"CVE-2025-13845","description":"CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.","state":"PUBLISHED","assigner":"schneider","published_at":"2026-01-15 19:16:02","updated_at":"2026-04-27 17:26:56"},"problem_types":["CWE-416","CWE-416 CWE-416 Use After Free"],"metrics":[{"version":"4.0","source":"cybersecurity@se.com","type":"Secondary","score":"8.4","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.4","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.4,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"ACTIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-04.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-04.pdf","refsource":"cybersecurity@se.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-13845","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-13845","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure Power Build Rapsody","version":"affected FR v2.8.1.0300 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure Power Build Rapsody","version":"affected ESP v2.8.5.0200 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure Power Build Rapsody","version":"affected PT v2.8.7.0100 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure Power Build Rapsody","version":"affected BEL (FR) v2.8.8.0100 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure Power Build Rapsody","version":"affected BEL (EN) v2.8.3.0100 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure Power Build Rapsody","version":"affected INT (EN) v2.8.4.0300 and prior","platforms":[]},{"source":"CNA","vendor":"Schneider Electric","product":"EcoStruxure Power Build Rapsody","version":"affected NL v2.8.2.0000 and prior","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2025","cve_id":"13845","vulnerable":"1","versionEndIncluding":"2.8.1.0300","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_build_-_rapsody","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"fr","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"13845","vulnerable":"1","versionEndIncluding":"2.8.2.0000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_build_-_rapsody","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"nl","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"13845","vulnerable":"1","versionEndIncluding":"2.8.3.0100","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_build_-_rapsody","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"bel_en","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"13845","vulnerable":"1","versionEndIncluding":"2.8.4.0300","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_build_-_rapsody","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"int_en","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"13845","vulnerable":"1","versionEndIncluding":"2.8.5.0200","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_build_-_rapsody","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"esp","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"13845","vulnerable":"1","versionEndIncluding":"2.8.7.0100","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_build_-_rapsody","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"pt","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"13845","vulnerable":"1","versionEndIncluding":"2.8.8.0100","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_power_build_-_rapsody","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"bel_fr","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"13845","cve":"CVE-2025-13845","epss":"0.000360000","percentile":"0.106140000","score_date":"2026-04-27","updated_at":"2026-04-28 00:06:43"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-13845","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-01-15T18:52:53.300481Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-01-15T18:54:16.308Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure Power Build Rapsody","vendor":"Schneider Electric","versions":[{"status":"affected","version":"FR v2.8.1.0300 and prior"},{"status":"affected","version":"ESP v2.8.5.0200 and prior"},{"status":"affected","version":"PT v2.8.7.0100 and prior"},{"status":"affected","version":"BEL (FR) v2.8.8.0100 and prior"},{"status":"affected","version":"BEL (EN) v2.8.3.0100 and prior"},{"status":"affected","version":"INT (EN) v2.8.4.0300 and prior"},{"status":"affected","version":"NL v2.8.2.0000 and prior"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody."}],"value":"CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.4,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"ACTIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-416","description":"CWE-416 Use After Free","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-01-15T18:33:23.235Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-04.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.5.0"}}},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2025-13845","datePublished":"2026-01-15T18:33:23.235Z","dateReserved":"2025-12-01T19:20:04.243Z","dateUpdated":"2026-01-15T18:54:16.308Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-01-15 19:16:02","lastModifiedDate":"2026-04-27 17:26:56","problem_types":["CWE-416","CWE-416 CWE-416 Use After Free"],"metrics":{"cvssMetricV40":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:fr:*:*:*","versionEndIncluding":"2.8.1.0300","matchCriteriaId":"139FB737-5979-4991-B8D1-0289CE7BFC26"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:nl:*:*:*","versionEndIncluding":"2.8.2.0000","matchCriteriaId":"3112F8F2-CA70-42A5-B9CC-B45D4505713C"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_en:*:*:*","versionEndIncluding":"2.8.3.0100","matchCriteriaId":"74A96C2D-0AE4-4E83-9B71-1EB851C2E720"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:int_en:*:*:*","versionEndIncluding":"2.8.4.0300","matchCriteriaId":"C6B44E48-5EE4-4490-A970-D20248509D12"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:esp:*:*:*","versionEndIncluding":"2.8.5.0200","matchCriteriaId":"B21D31C7-EE0E-4A0B-AE3E-373F94B6E248"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:pt:*:*:*","versionEndIncluding":"2.8.7.0100","matchCriteriaId":"4BF53F49-DEBD-4FE5-87D9-74BF6D50AC55"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_fr:*:*:*","versionEndIncluding":"2.8.8.0100","matchCriteriaId":"ED8F7CF9-F7FC-46EF-8420-32E779333D88"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"13845","Ordinal":"1","Title":"CVE-2025-13845","CVE":"CVE-2025-13845","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"13845","Ordinal":"1","NoteData":"CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.","Type":"Description","Title":"CVE-2025-13845"}]}}}