{"api_version":"1","generated_at":"2026-10-27T07:58:10+00:00","cve":"CVE-2025-30046","urls":{"html":"https://cve.report/CVE-2025-30046","api":"https://cve.report/api/cve/CVE-2025-30046.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-30046","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-30046"},"summary":{"title":"Remote Code Execution in CGM CLININET","description":"In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges. \n\n\nThe vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.","state":"PUBLISHED","assigner":"CERT-PL","published_at":"2026-10-23 09:17:04","updated_at":"2026-10-23 16:28:32"},"problem_types":["CWE-250","CWE-250 CWE-250 Execution with Unnecessary Privileges"],"metrics":[{"version":"4.0","source":"cvd@cert.pl","type":"Secondary","score":"9","severity":"CRITICAL","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9,"baseSeverity":"CRITICAL","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"9","severity":"CRITICAL","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"ADJACENT","baseScore":9,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html","name":"https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html","refsource":"cvd@cert.pl","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert.pl/en/posts/2026/10/CVE-2025-30043/","name":"https://cert.pl/en/posts/2026/10/CVE-2025-30043/","refsource":"cvd@cert.pl","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-30046","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-30046","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"CGM","product":"CGM CLININET","version":"affected 2026.MS3 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unknown","modules":["HL7 communication"],"product":"CGM CLININET","vendor":"CGM","versions":[{"lessThanOrEqual":"2026.MS3","status":"affected","version":"0","versionType":"custom"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:cgm:cgm_clininet:*:*:*:*:*:*:*:*","versionEndIncluding":"2026.ms4","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker&nbsp;in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges.&nbsp;<div><br></div><div>The vulnerability was confirmed to affect versions up to&nbsp;2026.MS3 but later versions may also be vulnerable.</div>"}],"value":"In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges. \n\n\nThe vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"ADJACENT","baseScore":9,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-250","description":"CWE-250 Execution with Unnecessary Privileges","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-10-23T08:22:55.246Z","orgId":"4bb8329e-dd38-46c1-aafb-9bf32bcb93c6","shortName":"CERT-PL"},"references":[{"tags":["third-party-advisory"],"url":"https://cert.pl/en/posts/2026/10/CVE-2025-30043/"},{"tags":["product"],"url":"https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"}],"source":{"discovery":"EXTERNAL"},"title":"Remote Code Execution in CGM CLININET","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"4bb8329e-dd38-46c1-aafb-9bf32bcb93c6","assignerShortName":"CERT-PL","cveId":"CVE-2025-30046","datePublished":"2026-10-23T08:22:55.246Z","dateReserved":"2025-03-14T14:55:05.983Z","dateUpdated":"2026-10-23T08:22:55.246Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-10-23 09:17:04","lastModifiedDate":"2026-10-23 16:28:32","problem_types":["CWE-250","CWE-250 CWE-250 Execution with Unnecessary Privileges"],"metrics":{"cvssMetricV40":[{"source":"cvd@cert.pl","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9,"baseSeverity":"CRITICAL","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"30046","Ordinal":"1","Title":"Remote Code Execution in CGM CLININET","CVE":"CVE-2025-30046","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"30046","Ordinal":"1","NoteData":"In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges. \n\n\nThe vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.","Type":"Description","Title":"Remote Code Execution in CGM CLININET"}]}}}