{"api_version":"1","generated_at":"2026-10-23T13:55:13+00:00","cve":"CVE-2025-3277","urls":{"html":"https://cve.report/CVE-2025-3277","api":"https://cve.report/api/cve/CVE-2025-3277.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-3277","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-3277"},"summary":{"title":"CVE-2025-3277","description":"An integer overflow can be triggered in SQLite’s `concat_ws()` function. The resulting, truncated integer is then used to allocate a buffer. When SQLite then writes the resulting string to the buffer, it uses the original, untruncated size and thus a wild Heap Buffer overflow of size ~4GB can be triggered. This can result in arbitrary code execution.","state":"PUBLISHED","assigner":"Google","published_at":"2025-04-14 17:15:27","updated_at":"2026-10-15 02:18:04"},"problem_types":["CWE-122","CWE-190","CWE-122 CWE-122 Heap-based Buffer Overflow"],"metrics":[{"version":"4.0","source":"cve-coordination@google.com","type":"Secondary","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":6.9,"baseSeverity":"MEDIUM","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://sqlite.org/src/info/498e3f1cf57f164f","name":"https://sqlite.org/src/info/498e3f1cf57f164f","refsource":"cve-coordination@google.com","tags":["Patch"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-994087.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-994087.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-3277","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-3277","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"SQLite","product":"sqlite","version":"affected < 3.49.1","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM CROSSBOW Station Access Controller (SAC)","version":"affected V5.7 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","version":"affected V3.1.0 V3.1.5 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"王跃林 (Yuelin Wang)","lang":"en"}],"nvd_cpes":[{"cve_year":"2025","cve_id":"3277","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"sqlite","cpe5":"sqlite","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-3277","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-04-14T17:15:26.733637Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-04-14T18:07:24.569Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"},{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM CROSSBOW Station Access Controller (SAC)","vendor":"Siemens","versions":[{"lessThan":"V5.7","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","vendor":"Siemens","versions":[{"lessThan":"V3.1.5","status":"affected","version":"V3.1.0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-10-15T01:02:02.335Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-398330.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-994087.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"sqlite","vendor":"SQLite","versions":[{"status":"affected","version":"< 3.49.1"}]}],"credits":[{"lang":"en","type":"finder","value":"王跃林 (Yuelin Wang)"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An integer overflow can be triggered in SQLite’s `concat_ws()` function. The resulting, truncated integer is then used to allocate a buffer. When SQLite then writes the resulting string to the buffer, it uses the original, untruncated size and thus a wild Heap Buffer overflow of size ~4GB can be triggered. This can result in arbitrary code execution.<br><br>"}],"value":"An integer overflow can be triggered in SQLite’s `concat_ws()` function. The resulting, truncated integer is then used to allocate a buffer. When SQLite then writes the resulting string to the buffer, it uses the original, untruncated size and thus a wild Heap Buffer overflow of size ~4GB can be triggered. This can result in arbitrary code execution."}],"impacts":[{"capecId":"CAPEC-47","descriptions":[{"lang":"en","value":"CAPEC-47 Buffer Overflow via Parameter Expansion"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":6.9,"baseSeverity":"MEDIUM","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-122","description":"CWE-122 Heap-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2025-05-27T14:42:04.019Z","orgId":"14ed7db2-1595-443d-9d34-6215bf890778","shortName":"Google"},"references":[{"url":"https://sqlite.org/src/info/498e3f1cf57f164f"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"14ed7db2-1595-443d-9d34-6215bf890778","assignerShortName":"Google","cveId":"CVE-2025-3277","datePublished":"2025-04-14T16:50:48.902Z","dateReserved":"2025-04-04T14:24:39.857Z","dateUpdated":"2026-10-15T01:02:02.335Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-04-14 17:15:27","lastModifiedDate":"2026-10-15 02:18:04","problem_types":["CWE-122","CWE-190","CWE-122 CWE-122 Heap-based Buffer Overflow"],"metrics":{"cvssMetricV40":[{"source":"cve-coordination@google.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-04-14T17:15:26.733637Z","id":"CVE-2025-3277","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:sqlite:sqlite:*:*:*:*:*:*:*:*","versionStartIncluding":"3.44.0","versionEndExcluding":"3.49.1","matchCriteriaId":"42F127F3-9545-4944-86C7-38FE88E9DEBA"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"3277","Ordinal":"1","Title":"CVE-2025-3277","CVE":"CVE-2025-3277","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"3277","Ordinal":"1","NoteData":"An integer overflow can be triggered in SQLite’s `concat_ws()` function. The resulting, truncated integer is then used to allocate a buffer. When SQLite then writes the resulting string to the buffer, it uses the original, untruncated size and thus a wild Heap Buffer overflow of size ~4GB can be triggered. This can result in arbitrary code execution.","Type":"Description","Title":"CVE-2025-3277"}]}}}