{"api_version":"1","generated_at":"2026-10-20T17:48:55+00:00","cve":"CVE-2025-34215","urls":{"html":"https://cve.report/CVE-2025-34215","api":"https://cve.report/api/cve/CVE-2025-34215.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-34215","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-34215"},"summary":{"title":"Vasion Print (formerly PrinterLogic) Unauthenticated Firmware Update Endpoint RCE","description":"Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (only VA deployments) expose an unauthenticated firmware-upload flow: a public page returns a signed token usable at va-api/v1/update, and every Docker image contains the appliance’s private GPG key and hard-coded passphrase. An attacker who extracts the key and obtains a token can decrypt, modify, re-sign, upload, and trigger malicious firmware, gaining remote code execution. This vulnerability has been identified by the vendor as: V-2024-020 — Remote Code Execution.","state":"PUBLISHED","assigner":"VulnCheck","published_at":"2025-09-29 21:15:35","updated_at":"2026-06-17 09:13:40"},"problem_types":["CWE-306","CWE-321","CWE-306 CWE-306 Missing Authentication for Critical Function","CWE-321 CWE-321 Use of Hard-coded Cryptographic Key"],"metrics":[{"version":"4.0","source":"disclosure@vulncheck.com","type":"Secondary","score":"9.4","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.4,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"9.4","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.4,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}}],"references":[{"url":"https://help.printerlogic.com/va/Print/Security/Security-Bulletins.htm","name":"https://help.printerlogic.com/va/Print/Security/Security-Bulletins.htm","refsource":"disclosure@vulncheck.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm","name":"https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm","refsource":"disclosure@vulncheck.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.vulncheck.com/advisories/vasion-print-printerlogic-unauth-firmware-update-endpoint-rce","name":"https://www.vulncheck.com/advisories/vasion-print-printerlogic-unauth-firmware-update-endpoint-rce","refsource":"disclosure@vulncheck.com","tags":["Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#va-rce-02","name":"https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#va-rce-02","refsource":"134c704f-9b21-4f2e-91b3-4a467353bcc0","tags":["Exploit","Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-34215","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-34215","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Vasion","product":"Print Virtual Appliance Host","version":"affected 22.0.1026 semver","platforms":[]},{"source":"CNA","vendor":"Vasion","product":"Print Application","version":"affected 20.0.2702 semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Pierre Barre","lang":"en"}],"nvd_cpes":[{"cve_year":"2025","cve_id":"34215","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"vasion","cpe5":"virtual_appliance_application","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"34215","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"vasion","cpe5":"virtual_appliance_host","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"34215","cve":"CVE-2025-34215","epss":"0.011360000","percentile":"0.659930000","score_date":"2026-10-18","updated_at":"2026-10-19 00:13:06"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-34215","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2025-09-30T15:13:51.289719Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-09-30T15:19:34.437Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"references":[{"tags":["exploit"],"url":"https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#va-rce-02"}],"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","modules":["/admin/design/management_accountts_pcabout.php","/va‑api/v1/update","private key embedded in the appliance"],"product":"Print Virtual Appliance Host","vendor":"Vasion","versions":[{"lessThan":"22.0.1026","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","modules":["/admin/design/management_accountts_pcabout.php","/va‑api/v1/update","private key embedded in the appliance"],"product":"Print Application","vendor":"Vasion","versions":[{"lessThan":"20.0.2702","status":"affected","version":"0","versionType":"semver"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:*","versionEndExcluding":"22.0.1026","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:*","versionEndExcluding":"20.0.2702","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"Pierre Barre"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version <span style=\"background-color: rgb(245, 244, 247);\">22.0.1026</span> and Application prior to version <span style=\"background-color: rgb(245, 244, 247);\">20.0.2702</span> (only VA deployments) expose an unauthenticated firmware-upload flow: a public page returns a signed token usable at va-api/v1/update, and every Docker image contains the appliance’s private GPG key and hard-coded passphrase. An attacker who extracts the key and obtains a token can decrypt, modify, re-sign, upload, and trigger malicious firmware, gaining remote code execution.&nbsp;This vulnerability has been identified by the vendor as: V-2024-020 — Remote Code Execution.<br>"}],"value":"Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (only VA deployments) expose an unauthenticated firmware-upload flow: a public page returns a signed token usable at va-api/v1/update, and every Docker image contains the appliance’s private GPG key and hard-coded passphrase. An attacker who extracts the key and obtains a token can decrypt, modify, re-sign, upload, and trigger malicious firmware, gaining remote code execution. This vulnerability has been identified by the vendor as: V-2024-020 — Remote Code Execution."}],"impacts":[{"capecId":"CAPEC-115","descriptions":[{"lang":"en","value":"CAPEC-115 Authentication Bypass"}]},{"capecId":"CAPEC-186","descriptions":[{"lang":"en","value":"CAPEC-186 Malicious Software Update"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.4,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-321","description":"CWE-321 Use of Hard-coded Cryptographic Key","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-15T11:15:24.734Z","orgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","shortName":"VulnCheck"},"references":[{"tags":["technical-description"],"url":"https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#va-rce-02"},{"tags":["vendor-advisory","patch"],"url":"https://help.printerlogic.com/va/Print/Security/Security-Bulletins.htm"},{"tags":["vendor-advisory","patch"],"url":"https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm"},{"tags":["third-party-advisory"],"url":"https://www.vulncheck.com/advisories/vasion-print-printerlogic-unauth-firmware-update-endpoint-rce"}],"source":{"discovery":"INTERNAL"},"title":"Vasion Print (formerly PrinterLogic) Unauthenticated Firmware Update Endpoint RCE","x_generator":{"engine":"vulncheck"}}},"cveMetadata":{"assignerOrgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","assignerShortName":"VulnCheck","cveId":"CVE-2025-34215","datePublished":"2025-09-29T20:43:12.104Z","dateReserved":"2025-04-15T19:15:22.572Z","dateUpdated":"2026-05-15T11:15:24.734Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-09-29 21:15:35","lastModifiedDate":"2026-06-17 09:13:40","problem_types":["CWE-306","CWE-321","CWE-306 CWE-306 Missing Authentication for Critical Function","CWE-321 CWE-321 Use of Hard-coded Cryptographic Key"],"metrics":{"cvssMetricV40":[{"source":"disclosure@vulncheck.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.4,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-09-30T15:13:51.289719Z","id":"CVE-2025-34215","options":[{"exploitation":"poc"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:*","versionEndExcluding":"20.0.2702","matchCriteriaId":"946E2403-6E75-419C-A75E-7C93A0536EEE"},{"vulnerable":true,"criteria":"cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:*","versionEndExcluding":"22.0.1026","matchCriteriaId":"E22EC9BB-5D58-439B-A187-ACD43F8B8D3B"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"34215","Ordinal":"1","Title":"Vasion Print (formerly PrinterLogic) Unauthenticated Firmware Up","CVE":"CVE-2025-34215","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"34215","Ordinal":"1","NoteData":"Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (only VA deployments) expose an unauthenticated firmware-upload flow: a public page returns a signed token usable at va-api/v1/update, and every Docker image contains the appliance’s private GPG key and hard-coded passphrase. An attacker who extracts the key and obtains a token can decrypt, modify, re-sign, upload, and trigger malicious firmware, gaining remote code execution. This vulnerability has been identified by the vendor as: V-2024-020 — Remote Code Execution.","Type":"Description","Title":"Vasion Print (formerly PrinterLogic) Unauthenticated Firmware Up"}]}}}