{"api_version":"1","generated_at":"2026-09-04T02:53:01+00:00","cve":"CVE-2025-3511","urls":{"html":"https://cve.report/CVE-2025-3511","api":"https://cve.report/api/cve/CVE-2025-3511.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-3511","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-3511"},"summary":{"title":"CVE-2025-3511","description":"Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.","state":"PUBLISHED","assigner":"Mitsubishi","published_at":"2025-04-25 06:15:45","updated_at":"2026-08-27 06:16:50"},"problem_types":["CWE-1284","CWE-1284 CWE-1284 Improper Validation of Specified Quantity in Input"],"metrics":[{"version":"3.1","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-128-03","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-128-03","refsource":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://jvn.jp/vu/JVNVU96620683/","name":"https://jvn.jp/vu/JVNVU96620683/","refsource":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf","name":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf","refsource":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-3511","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-3511","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32D","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32T","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32D","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32T","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GNCF1-32D","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GNCF1-32T","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GNCE3-32D","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN12A4-16D","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN12A2-16T","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-16D","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-16T","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-16D","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-16T","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE","version":"affected 09 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4","version":"affected 07 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4","version":"affected 07 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4","version":"affected 07 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4","version":"affected 07 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN FPGA module NZ2GN2S-D41P01","version":"affected 01","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN FPGA module NZ2GN2S-D41D01","version":"affected 01","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN FPGA module NZ2GN2S-D41PD02","version":"affected 01","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300","version":"affected 1.08J and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60","version":"affected 1.08J and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2","version":"affected 26 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP","version":"affected 10 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX","version":"affected 05 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series Ethernet Interface Module RJ71EN71","version":"affected 85 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Master/Local Station Communication LSI CP610 NZ2GACP610-60","version":"affected 05 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"CC-Link IE TSN Master/Local Station Communication LSI CP610 NZ2KT-NPETNG51","version":"affected 05 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS","version":"affected 1.020 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET","version":"affected 1.200 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP","version":"affected 1.106 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CPU module R04ENCPU (Network part)","version":"affected 85 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CPU module R08ENCPU (Network part)","version":"affected 85 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CPU module R16ENCPU (Network part)","version":"affected 85 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CPU module R32ENCPU (Network part)","version":"affected 85 and prior","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series CPU module R120ENCPU (Network part)","version":"affected 85 and prior","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"3511","cve":"CVE-2025-3511","epss":"0.008760000","percentile":"0.563810000","score_date":"2026-08-27","updated_at":"2026-08-28 00:03:39"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-3511","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-10-23T17:46:29.102151Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-10-23T17:46:36.083Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32D","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32T","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32D","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32T","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GNCF1-32D","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GNCF1-32T","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GNCE3-32D","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN12A4-16D","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN12A2-16T","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-16D","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-16T","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-16D","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-16T","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"09 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"07 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"07 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"07 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"07 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN FPGA module NZ2GN2S-D41P01","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"01"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN FPGA module NZ2GN2S-D41D01","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"01"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN FPGA module NZ2GN2S-D41PD02","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"01"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.08J and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.08J and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"26 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"10 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"05 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series Ethernet Interface Module RJ71EN71","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"85 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Master/Local Station Communication LSI CP610 NZ2GACP610-60","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"05 and prior"}]},{"defaultStatus":"unaffected","product":"CC-Link IE TSN Master/Local Station Communication LSI CP610 NZ2KT-NPETNG51","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"05 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.020 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.200 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"1.106 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CPU module R04ENCPU (Network part)","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"85 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CPU module R08ENCPU (Network part)","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"85 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CPU module R16ENCPU (Network part)","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"85 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CPU module R32ENCPU (Network part)","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"85 and prior"}]},{"defaultStatus":"unaffected","product":"MELSEC iQ-R Series CPU module R120ENCPU (Network part)","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"85 and prior"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets."}],"value":"Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets."}],"impacts":[{"descriptions":[{"lang":"en","value":"Denial-of-Service"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1284","description":"CWE-1284 Improper Validation of Specified Quantity in Input","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-27T05:32:29.296Z","orgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","shortName":"Mitsubishi"},"references":[{"tags":["vendor-advisory"],"url":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf"},{"tags":["government-resource"],"url":"https://jvn.jp/vu/JVNVU96620683/"},{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-128-03"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","assignerShortName":"Mitsubishi","cveId":"CVE-2025-3511","datePublished":"2025-04-25T05:14:43.758Z","dateReserved":"2025-04-11T04:10:12.030Z","dateUpdated":"2026-08-27T05:32:29.296Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-04-25 06:15:45","lastModifiedDate":"2026-08-27 06:16:50","problem_types":["CWE-1284","CWE-1284 CWE-1284 Improper Validation of Specified Quantity in Input"],"metrics":{"cvssMetricV31":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-10-23T17:46:29.102151Z","id":"CVE-2025-3511","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"3511","Ordinal":"1","Title":"CVE-2025-3511","CVE":"CVE-2025-3511","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"3511","Ordinal":"1","NoteData":"Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.","Type":"Description","Title":"CVE-2025-3511"}]}}}