{"api_version":"1","generated_at":"2026-04-22T16:04:56+00:00","cve":"CVE-2025-40745","urls":{"html":"https://cve.report/CVE-2025-40745","api":"https://cve.report/api/cve/CVE-2025-40745.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-40745","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-40745"},"summary":{"title":"CVE-2025-40745","description":"A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.","state":"PUBLISHED","assigner":"siemens","published_at":"2026-04-14 09:16:34","updated_at":"2026-04-17 15:18:16"},"problem_types":["CWE-295","CWE-295 CWE-295: Improper Certificate Validation"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"6.3","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"6.3","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","data":{"baseScore":6.3,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Primary","score":"3.7","severity":"LOW","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":3.7,"baseSeverity":"LOW","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"3.7","severity":"LOW","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","data":{"baseScore":3.7,"baseSeverity":"LOW","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-981622.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-981622.html","refsource":"productcert@siemens.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-40745","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-40745","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"Siemens Software Center","version":"affected V3.5.8.2 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Simcenter 3D","version":"affected V2506.6000 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Simcenter Femap","version":"affected V2506.0002 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Simcenter STAR-CCM+","version":"affected V2602 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Solid Edge SE2025","version":"affected V225.0 Update 13 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Solid Edge SE2026","version":"affected V226.0 Update 04 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Tecnomatix Plant Simulation","version":"affected V2504.0008 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"40745","cve":"CVE-2025-40745","epss":"0.000220000","percentile":"0.061610000","score_date":"2026-04-21","updated_at":"2026-04-22 00:07:41"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-40745","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-04-14T13:37:06.968025Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-04-14T13:38:29.751Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"Siemens Software Center","vendor":"Siemens","versions":[{"lessThan":"V3.5.8.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Simcenter 3D","vendor":"Siemens","versions":[{"lessThan":"V2506.6000","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Simcenter Femap","vendor":"Siemens","versions":[{"lessThan":"V2506.0002","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Simcenter STAR-CCM+","vendor":"Siemens","versions":[{"lessThan":"V2602","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Solid Edge SE2025","vendor":"Siemens","versions":[{"lessThan":"V225.0 Update 13","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Solid Edge SE2026","vendor":"Siemens","versions":[{"lessThan":"V226.0 Update 04","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Tecnomatix Plant Simulation","vendor":"Siemens","versions":[{"lessThan":"V2504.0008","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks."}],"metrics":[{"cvssV3_1":{"baseScore":3.7,"baseSeverity":"LOW","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}},{"cvssV4_0":{"baseScore":6.3,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-295","description":"CWE-295: Improper Certificate Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-04-14T08:40:38.637Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-981622.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2025-40745","datePublished":"2026-04-14T08:40:38.637Z","dateReserved":"2025-04-16T08:39:30.030Z","dateUpdated":"2026-04-14T13:38:29.751Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-04-14 09:16:34","lastModifiedDate":"2026-04-17 15:18:16","problem_types":["CWE-295","CWE-295 CWE-295: Improper Certificate Validation"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":3.7,"baseSeverity":"LOW","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.2,"impactScore":1.4}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"40745","Ordinal":"1","Title":"CVE-2025-40745","CVE":"CVE-2025-40745","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"40745","Ordinal":"1","NoteData":"A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.","Type":"Description","Title":"CVE-2025-40745"}]}}}