{"api_version":"1","generated_at":"2026-05-13T00:30:58+00:00","cve":"CVE-2025-40948","urls":{"html":"https://cve.report/CVE-2025-40948","api":"https://cve.report/api/cve/CVE-2025-40948.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-40948","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-40948"},"summary":{"title":"CVE-2025-40948","description":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly validate input in the web server's JSON-RPC interface.\r\n\r\nThis could allow an authenticated remote attacker to read arbitrary files from the underlying operating system's filesystem with root privileges.","state":"PUBLISHED","assigner":"siemens","published_at":"2026-05-12 10:16:43","updated_at":"2026-05-12 14:19:41"},"problem_types":["CWE-88","CWE-88 CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"6.1","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"6.1","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N","data":{"baseScore":6.1,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Primary","score":"6.8","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"6.8","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N","data":{"baseScore":6.8,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-973901.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-973901.html","refsource":"productcert@siemens.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-40948","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-40948","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX5000","version":"affected V2.17.1 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"40948","cve":"CVE-2025-40948","epss":"0.000370000","percentile":"0.112050000","score_date":"2026-05-12","updated_at":"2026-05-13 00:11:53"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-40948","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-05-12T12:43:17.469738Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-05-12T12:43:43.061Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000RE","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1400","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1500","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1501","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1510","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1511","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1512","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1524","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1536","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX5000","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly validate input in the web server's JSON-RPC interface.\r\n\r\nThis could allow an authenticated remote attacker to read arbitrary files from the underlying operating system's filesystem with root privileges."}],"metrics":[{"cvssV3_1":{"baseScore":6.8,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N","version":"3.1"}},{"cvssV4_0":{"baseScore":6.1,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-88","description":"CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-12T08:20:52.849Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-973901.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2025-40948","datePublished":"2026-05-12T08:20:52.849Z","dateReserved":"2025-04-16T09:06:15.879Z","dateUpdated":"2026-05-12T12:43:43.061Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-05-12 10:16:43","lastModifiedDate":"2026-05-12 14:19:41","problem_types":["CWE-88","CWE-88 CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":4}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"40948","Ordinal":"1","Title":"CVE-2025-40948","CVE":"CVE-2025-40948","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"40948","Ordinal":"1","NoteData":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly validate input in the web server's JSON-RPC interface.\r\n\r\nThis could allow an authenticated remote attacker to read arbitrary files from the underlying operating system's filesystem with root privileges.","Type":"Description","Title":"CVE-2025-40948"}]}}}