{"api_version":"1","generated_at":"2026-05-13T00:31:48+00:00","cve":"CVE-2025-40949","urls":{"html":"https://cve.report/CVE-2025-40949","api":"https://cve.report/api/cve/CVE-2025-40949.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-40949","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-40949"},"summary":{"title":"CVE-2025-40949","description":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly sanitize user-supplied input in the Scheduler functionality of the Web UI, allowing commands to be injected into the task scheduling backend.\r\n\r\nThis could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system.","state":"PUBLISHED","assigner":"siemens","published_at":"2026-05-12 10:16:43","updated_at":"2026-05-12 14:19:41"},"problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"8.9","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.9,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"8.9","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","data":{"baseScore":8.9,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Primary","score":"9.1","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"9.1","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","data":{"baseScore":9.1,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-081142.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-081142.html","refsource":"productcert@siemens.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-40949","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-40949","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","version":"affected V2.17.1 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"RUGGEDCOM ROX RX5000","version":"affected V2.17.1 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"40949","cve":"CVE-2025-40949","epss":"0.001730000","percentile":"0.382420000","score_date":"2026-05-12","updated_at":"2026-05-13 00:11:53"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX MX5000RE","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1400","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1500","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1501","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1510","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1511","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1512","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1524","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX1536","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"RUGGEDCOM ROX RX5000","vendor":"Siemens","versions":[{"lessThan":"V2.17.1","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly sanitize user-supplied input in the Scheduler functionality of the Web UI, allowing commands to be injected into the task scheduling backend.\r\n\r\nThis could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system."}],"metrics":[{"cvssV3_1":{"baseScore":9.1,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},{"cvssV4_0":{"baseScore":8.9,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-12T08:20:53.983Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-081142.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2025-40949","datePublished":"2026-05-12T08:20:53.983Z","dateReserved":"2025-04-16T09:06:15.880Z","dateUpdated":"2026-05-12T08:20:53.983Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-05-12 10:16:43","lastModifiedDate":"2026-05-12 14:19:41","problem_types":["CWE-78","CWE-78 CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.9,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.3,"impactScore":6}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"40949","Ordinal":"1","Title":"CVE-2025-40949","CVE":"CVE-2025-40949","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"40949","Ordinal":"1","NoteData":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly sanitize user-supplied input in the Scheduler functionality of the Web UI, allowing commands to be injected into the task scheduling backend.\r\n\r\nThis could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system.","Type":"Description","Title":"CVE-2025-40949"}]}}}