{"api_version":"1","generated_at":"2026-06-03T11:06:11+00:00","cve":"CVE-2025-41669","urls":{"html":"https://cve.report/CVE-2025-41669","api":"https://cve.report/api/cve/CVE-2025-41669.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-41669","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-41669"},"summary":{"title":"Insufficient Verification of Data Authenticity","description":"The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control.","state":"PUBLISHED","assigner":"CERTVDE","published_at":"2026-05-27 08:16:39","updated_at":"2026-05-27 14:53:22"},"problem_types":["CWE-347","CWE-347 CWE-347 Improper Verification of Cryptographic Signature"],"metrics":[{"version":"4.0","source":"info@cert.vde.com","type":"Secondary","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"info@cert.vde.com","type":"Primary","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.certvde.com/en/advisories/VDE-2026-050/","name":"https://www.certvde.com/en/advisories/VDE-2026-050/","refsource":"info@cert.vde.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-41669","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-41669","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Phoenix Contact","product":"AXC F 1152","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"AXC F 1252","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"AXC F 2000 EA","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"AXC F 2152","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"AXC F 3152","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"BPC 9102S","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"EPC 1522","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"RFC 4072R","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"RFC 4072S","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"VL3 UPC 2440 EDGE","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"VPLCNEXT CONTROL 1000","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"VPLCNEXT CONTROL 2000","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"VPLCNEXT CONTROL 3000","version":"affected 0.0.0 2026.0.3 semver","platforms":[]},{"source":"CNA","vendor":"Phoenix Contact","product":"VPLCNEXT CONTROL 500","version":"affected 0.0.0 2026.0.3 semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Diego Giubertoni from Nozomi","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"41669","cve":"CVE-2025-41669","epss":"0.000580000","percentile":"0.183570000","score_date":"2026-05-31","updated_at":"2026-06-01 00:08:19"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-41669","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-05-27T11:53:22.514056Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-05-27T12:04:07.823Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"AXC F 1152","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"AXC F 1252","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"AXC F 2000 EA","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"AXC F 2152","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"AXC F 3152","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"BPC 9102S","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"EPC 1522","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"RFC 4072R","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"RFC 4072S","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"VL3 UPC 2440 EDGE","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"VPLCNEXT CONTROL 1000","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"VPLCNEXT CONTROL 2000","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"VPLCNEXT CONTROL 3000","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"VPLCNEXT CONTROL 500","vendor":"Phoenix Contact","versions":[{"lessThan":"2026.0.3","status":"affected","version":"0.0.0","versionType":"semver"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:axc_f_1152:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:axc_f_1252:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:axc_f_2000_ea:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:axc_f_2152:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:axc_f_3152:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:bpc_9102s:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:epc_1522:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:rfc_4072r:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:rfc_4072s:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:vl3_upc_2440_edge:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:vplcnext_control_1000:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:vplcnext_control_2000:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:vplcnext_control_3000:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:phoenix_contact:vplcnext_control_500:*:*:*:*:*:*:*:*","versionEndExcluding":"2026.0.3","versionStartIncluding":"0.0.0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"Diego Giubertoni from Nozomi"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control."}],"value":"The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-347","description":"CWE-347 Improper Verification of Cryptographic Signature","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-27T07:18:28.236Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE"},"references":[{"url":"https://www.certvde.com/en/advisories/VDE-2026-050/"}],"source":{"advisory":"VDE-2026-050","defect":["CERT@VDE#641839"],"discovery":"UNKNOWN"},"title":"Insufficient Verification of Data Authenticity","x_generator":{"engine":"Vulnogram 0.4.0"}}},"cveMetadata":{"assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","assignerShortName":"CERTVDE","cveId":"CVE-2025-41669","datePublished":"2026-05-27T07:18:28.236Z","dateReserved":"2025-04-16T11:17:48.308Z","dateUpdated":"2026-05-27T12:04:07.823Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-05-27 08:16:39","lastModifiedDate":"2026-05-27 14:53:22","problem_types":["CWE-347","CWE-347 CWE-347 Improper Verification of Cryptographic Signature"],"metrics":{"cvssMetricV40":[{"source":"info@cert.vde.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"info@cert.vde.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"41669","Ordinal":"1","Title":"Insufficient Verification of Data Authenticity","CVE":"CVE-2025-41669","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"41669","Ordinal":"1","NoteData":"The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control.","Type":"Description","Title":"Insufficient Verification of Data Authenticity"}]}}}