{"api_version":"1","generated_at":"2026-05-27T20:42:37+00:00","cve":"CVE-2025-41712","urls":{"html":"https://cve.report/CVE-2025-41712","api":"https://cve.report/api/cve/CVE-2025-41712.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-41712","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-41712"},"summary":{"title":"Incorrect Permission Assignment on power analyzer","description":"An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server.","state":"PUBLISHED","assigner":"CERTVDE","published_at":"2026-03-10 18:17:56","updated_at":"2026-04-27 19:22:08"},"problem_types":["CWE-732","CWE-732 CWE-732 Incorrect Permission Assignment for Critical Resource"],"metrics":[{"version":"3.1","source":"info@cert.vde.com","type":"Primary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json","name":"https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json","refsource":"info@cert.vde.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json","name":"https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json","refsource":"info@cert.vde.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://certvde.com/en/advisories/VDE-2025-079/","name":"https://certvde.com/en/advisories/VDE-2025-079/","refsource":"info@cert.vde.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://certvde.com/en/advisories/VDE-2025-096/","name":"https://certvde.com/en/advisories/VDE-2025-096/","refsource":"info@cert.vde.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-41712","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-41712","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Janitza","product":"UMG 96RM-E 24V(5222063)","version":"affected 0.0 3.13 custom","platforms":[]},{"source":"CNA","vendor":"Janitza","product":"UMG 96RM-E 230V(5222062)","version":"affected 0.0 3.13 custom","platforms":[]},{"source":"CNA","vendor":"Weidmueller","product":"ENERGY METER 750-230 (2540910000)","version":"affected 0.0 3.13 custom","platforms":[]},{"source":"CNA","vendor":"Weidmueller","product":"ENERGY METER 750-24 (2540900000)","version":"affected 0.0 3.13 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Deutsche Telekom Security (DT Security)","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"41712","cve":"CVE-2025-41712","epss":"0.000360000","percentile":"0.107500000","score_date":"2026-04-27","updated_at":"2026-04-28 00:06:42"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-41712","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-03-10T15:35:50.983890Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-03-10T16:51:35.020Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"UMG 96RM-E 24V(5222063)","vendor":"Janitza","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"UMG 96RM-E 230V(5222062)","vendor":"Janitza","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"ENERGY METER 750-230 (2540910000)","vendor":"Weidmueller","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"ENERGY METER 750-24 (2540900000)","vendor":"Weidmueller","versions":[{"lessThanOrEqual":"3.13","status":"affected","version":"0.0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"reporter","user":"00000000-0000-4000-9000-000000000000","value":"Deutsche Telekom Security (DT Security)"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server.</span><br>"}],"value":"An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-732","description":"CWE-732 Incorrect Permission Assignment for Critical Resource","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-03-10T08:27:10.120Z","orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE"},"references":[{"tags":["vendor-advisory"],"url":"https://certvde.com/en/advisories/VDE-2025-079/"},{"tags":["vendor-advisory"],"url":"https://certvde.com/en/advisories/VDE-2025-096/"},{"tags":["vendor-advisory"],"url":"https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json"},{"tags":["vendor-advisory"],"url":"https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json"}],"source":{"discovery":"UNKNOWN"},"title":"Incorrect Permission Assignment on power analyzer","x_generator":{"engine":"Vulnogram 0.1.0-dev"}}},"cveMetadata":{"assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","assignerShortName":"CERTVDE","cveId":"CVE-2025-41712","datePublished":"2026-03-10T08:27:10.120Z","dateReserved":"2025-04-16T11:17:48.311Z","dateUpdated":"2026-03-10T16:51:35.020Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-03-10 18:17:56","lastModifiedDate":"2026-04-27 19:22:08","problem_types":["CWE-732","CWE-732 CWE-732 Incorrect Permission Assignment for Critical Resource"],"metrics":{"cvssMetricV31":[{"source":"info@cert.vde.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"41712","Ordinal":"1","Title":"Incorrect Permission Assignment on power analyzer","CVE":"CVE-2025-41712","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"41712","Ordinal":"1","NoteData":"An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server.","Type":"Description","Title":"Incorrect Permission Assignment on power analyzer"}]}}}