{"api_version":"1","generated_at":"2026-06-05T07:55:30+00:00","cve":"CVE-2025-49848","urls":{"html":"https://cve.report/CVE-2025-49848","api":"https://cve.report/api/cve/CVE-2025-49848.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-49848","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-49848"},"summary":{"title":"Out-of-bounds Write in LS Electric GMWin 4","description":"An out-of-bounds write vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing past the end of allocated data structures.","state":"PUBLISHED","assigner":"icscert","published_at":"2025-06-17 19:15:34","updated_at":"2026-06-04 21:16:28"},"problem_types":["CWE-787","CWE-787 CWE-787 Out-of-bounds Write"],"metrics":[{"version":"4.0","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"8.4","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.4","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.4,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"ACTIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"ics-cert@hq.dhs.gov","type":"Secondary","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.ls-electric.com/support","name":"https://www.ls-electric.com/support","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-02","name":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-02","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-168-02.json","name":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-168-02.json","refsource":"ics-cert@hq.dhs.gov","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-49848","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-49848","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"LS Electric","product":"GMWin 4","version":"affected Version 4.18","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"LS Electric GMWin 4 has been discontinued and is no longer available for service. LS electric recommends users to use the  XGT series https://www.ls-electric.com/products/category/Smart_Automation_Solution/PLC/XGT_Series_-*XGK,_XGI,_XGR*-  as a replacement.\n\nFor more information, contact  LS Electric https://www.ls-electric.com/support .","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Michael Heinzl reported these vulnerabilities to CISA.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"49848","cve":"CVE-2025-49848","epss":"0.001320000","percentile":"0.322310000","score_date":"2026-06-04","updated_at":"2026-06-05 00:02:13"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-49848","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2025-06-17T20:32:00.962851Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-06-17T20:33:43.128Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"GMWin 4","vendor":"LS Electric","versions":[{"status":"affected","version":"Version 4.18"}]}],"credits":[{"lang":"en","type":"finder","value":"Michael Heinzl reported these vulnerabilities to CISA."}],"datePublic":"2025-06-17T18:28:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>An out-of-bounds write vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing past the end of allocated data structures.</p><br>"}],"value":"An out-of-bounds write vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing past the end of allocated data structures."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.4,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"ACTIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"CWE-787 Out-of-bounds Write","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-06-04T20:49:50.946Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-02"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-168-02.json"},{"url":"https://www.ls-electric.com/support"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>LS Electric GMWin 4 has been discontinued and is no longer available for service. LS electric recommends users to use the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.ls-electric.com/products/category/Smart_Automation_Solution/PLC/XGT_Series_-*XGK,_XGI,_XGR*-\">XGT series</a>&nbsp;as a replacement.</p><p>For more information, contact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.ls-electric.com/support\">LS Electric</a>.</p>\n\n<br>"}],"value":"LS Electric GMWin 4 has been discontinued and is no longer available for service. LS electric recommends users to use the  XGT series https://www.ls-electric.com/products/category/Smart_Automation_Solution/PLC/XGT_Series_-*XGK,_XGI,_XGR*-  as a replacement.\n\nFor more information, contact  LS Electric https://www.ls-electric.com/support ."}],"source":{"advisory":"ICSA-25-168-02","discovery":"EXTERNAL"},"tags":["unsupported-when-assigned"],"title":"Out-of-bounds Write in LS Electric GMWin 4","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2025-49848","datePublished":"2025-06-17T18:31:45.825Z","dateReserved":"2025-06-11T15:07:28.495Z","dateUpdated":"2026-06-04T20:49:50.946Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-06-17 19:15:34","lastModifiedDate":"2026-06-04 21:16:28","problem_types":["CWE-787","CWE-787 CWE-787 Out-of-bounds Write"],"metrics":{"cvssMetricV40":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"49848","Ordinal":"1","Title":"Out-of-bounds Write in LS Electric GMWin 4","CVE":"CVE-2025-49848","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"49848","Ordinal":"1","NoteData":"An out-of-bounds write vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing past the end of allocated data structures.","Type":"Description","Title":"Out-of-bounds Write in LS Electric GMWin 4"}]}}}