{"api_version":"1","generated_at":"2026-07-23T12:51:54+00:00","cve":"CVE-2025-52606","urls":{"html":"https://cve.report/CVE-2025-52606","api":"https://cve.report/api/cve/CVE-2025-52606.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-52606","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-52606"},"summary":{"title":"HCL iControl was affected by Weak Input Validation vulnerability. .","description":"HCL iControl was affected by Weak Input Validation vulnerability. This weakness is caused during implementation of an architectural security tactic. Received input that is expected to be of a certain type, but it does not validate or incorrectly validates that the input is actually of the expected type.","state":"PUBLISHED","assigner":"HCL","published_at":"2026-06-04 12:16:23","updated_at":"2026-07-22 20:10:00"},"problem_types":["CWE-209","CWE-209 CWE-209 : Generation of Error Message Containing Sensitive Information."],"metrics":[{"version":"3.1","source":"psirt@hcl.com","type":"Secondary","score":"4.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"4.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","version":"3.1"}}],"references":[{"url":"https://support.hcl-software.com/csm?id=kb_article&sysparm_article=KB0131178","name":"https://support.hcl-software.com/csm?id=kb_article&sysparm_article=KB0131178","refsource":"psirt@hcl.com","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-52606","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-52606","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"HCL","product":"iControl","version":"affected 4.0.0","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2025","cve_id":"52606","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"hcltech","cpe5":"icontrol","cpe6":"4.0.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"52606","cve":"CVE-2025-52606","epss":"0.001690000","percentile":"0.066410000","score_date":"2026-07-22","updated_at":"2026-07-23 00:09:30"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-52606","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-06-04T13:08:29.528112Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-06-04T13:08:41.096Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"iControl","vendor":"HCL","versions":[{"status":"affected","version":"4.0.0"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"HCL iControl was affected by Weak Input Validation vulnerability. This weakness is caused during implementation of an architectural security tactic. Received input that is expected to be of a certain type, but it does not validate or incorrectly validates that the input is actually of the expected type."}],"value":"HCL iControl was affected by Weak Input Validation vulnerability. This weakness is caused during implementation of an architectural security tactic. Received input that is expected to be of a certain type, but it does not validate or incorrectly validates that the input is actually of the expected type."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-209","description":"CWE-209 : Generation of Error Message Containing Sensitive Information.","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-06-04T12:00:32.414Z","orgId":"1e47fe04-f25f-42fa-b674-36de2c5e3cfc","shortName":"HCL"},"references":[{"url":"https://support.hcl-software.com/csm?id=kb_article&sysparm_article=KB0131178"}],"source":{"discovery":"UNKNOWN"},"title":"HCL iControl was affected by Weak Input Validation vulnerability. .","x_generator":{"engine":"Vulnogram 1.0.0"}}},"cveMetadata":{"assignerOrgId":"1e47fe04-f25f-42fa-b674-36de2c5e3cfc","assignerShortName":"HCL","cveId":"CVE-2025-52606","datePublished":"2026-06-04T11:56:42.357Z","dateReserved":"2025-06-18T14:00:38.417Z","dateUpdated":"2026-06-04T13:08:41.096Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-06-04 12:16:23","lastModifiedDate":"2026-07-22 20:10:00","problem_types":["CWE-209","CWE-209 CWE-209 : Generation of Error Message Containing Sensitive Information."],"metrics":{"cvssMetricV31":[{"source":"psirt@hcl.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-06-04T13:08:29.528112Z","id":"CVE-2025-52606","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hcltech:icontrol:4.0.0:*:*:*:*:*:*:*","matchCriteriaId":"CBA4086C-B8EA-4506-9F03-6F87F6BC17B7"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"52606","Ordinal":"1","Title":"HCL iControl was affected by Weak Input Validation vulnerability","CVE":"CVE-2025-52606","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"52606","Ordinal":"1","NoteData":"HCL iControl was affected by Weak Input Validation vulnerability. This weakness is caused during implementation of an architectural security tactic. Received input that is expected to be of a certain type, but it does not validate or incorrectly validates that the input is actually of the expected type.","Type":"Description","Title":"HCL iControl was affected by Weak Input Validation vulnerability"}]}}}