{"api_version":"1","generated_at":"2026-11-04T00:19:49+00:00","cve":"CVE-2025-6541","urls":{"html":"https://cve.report/CVE-2025-6541","api":"https://cve.report/api/cve/CVE-2025-6541.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-6541","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-6541"},"summary":{"title":"OS command injection using information obtained from the web management interface","description":"An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.","state":"PUBLISHED","assigner":"TPLink","published_at":"2025-10-21 01:15:36","updated_at":"2026-06-17 10:02:06"},"problem_types":["CWE-78","CWE-78 CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":[{"version":"4.0","source":"f23511db-6c3e-4e32-a477-6aa17d310630","type":"Secondary","score":"8.6","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.6","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.6,"baseSeverity":"HIGH","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}},{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"8.8","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}}],"references":[{"url":"https://www.omadanetworks.com/us/business-networking/all-omada-router/","name":"https://www.omadanetworks.com/us/business-networking/all-omada-router/","refsource":"f23511db-6c3e-4e32-a477-6aa17d310630","tags":["Product"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/","name":"https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/","refsource":"f23511db-6c3e-4e32-a477-6aa17d310630","tags":["Product"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.tp-link.com/us/business-networking/soho-festa-gateway/","name":"https://www.tp-link.com/us/business-networking/soho-festa-gateway/","refsource":"f23511db-6c3e-4e32-a477-6aa17d310630","tags":["Product"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://support.omadanetworks.com/en/document/108455/","name":"https://support.omadanetworks.com/en/document/108455/","refsource":"f23511db-6c3e-4e32-a477-6aa17d310630","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-6541","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-6541","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"TP-Link Systems Inc.","product":"Omada gateways","version":"affected ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3 Firmware","platforms":[]},{"source":"CNA","vendor":"TP-Link Systems Inc.","product":"Festa gateways","version":"affected FR365 1.1.10, FR205 1.0.3, FR307 1.2.5 Firmware","platforms":[]},{"source":"CNA","vendor":"TP-Link Systems Inc.","product":"Omada Pro gateways","version":"affected G36 1.1.4, G611 1.2.2 Firmware","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er605","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er605_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er605_firmware","cpe6":"2.3.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er706w","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er706w-4g","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er706w-4g_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er706w-4g_firmware","cpe6":"1.2.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er706w_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er706w_firmware","cpe6":"1.2.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er707-m2","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er707-m2_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er707-m2_firmware","cpe6":"1.3.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er7206","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er7206_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er7206_firmware","cpe6":"2.2.2","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er7212pc","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er7212pc_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er7212pc_firmware","cpe6":"2.1.3","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er7412-m2","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er7412-m2_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er7412-m2_firmware","cpe6":"1.1.0","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"er8411","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er8411_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"er8411_firmware","cpe6":"1.3.3","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"fr205","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"fr205_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"fr205_firmware","cpe6":"1.0.3","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"fr307-m2","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"fr307-m2_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"fr307-m2_firmware","cpe6":"1.2.5","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"fr365","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"fr365_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"fr365_firmware","cpe6":"1.1.10","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"g36","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"g36_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"g36_firmware","cpe6":"1.1.4","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tp-link","cpe5":"g611","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"g611_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"6541","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tp-link","cpe5":"g611_firmware","cpe6":"1.2.2","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"6541","cve":"CVE-2025-6541","epss":"0.006850000","percentile":"0.516740000","score_date":"2026-10-18","updated_at":"2026-10-19 00:13:06"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2025-6541","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2025-10-21T13:56:36.534414Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-10-21T13:57:51.728Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"Omada gateways","vendor":"TP-Link Systems Inc.","versions":[{"lessThan":"ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3","status":"affected","version":"0","versionType":"Firmware"}]},{"defaultStatus":"unaffected","product":"Festa gateways","vendor":"TP-Link Systems Inc.","versions":[{"lessThan":"FR365 1.1.10, FR205 1.0.3, FR307 1.2.5","status":"affected","version":"0","versionType":"Firmware"}]},{"defaultStatus":"unaffected","product":"Omada Pro gateways","vendor":"TP-Link Systems Inc.","versions":[{"lessThan":"G36 1.1.4, G611 1.2.2","status":"affected","version":"0","versionType":"Firmware"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."}],"value":"An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."}],"impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88 OS Command Injection"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.6,"baseSeverity":"HIGH","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2025-10-21T00:21:42.535Z","orgId":"f23511db-6c3e-4e32-a477-6aa17d310630","shortName":"TPLink"},"references":[{"tags":["vendor-advisory"],"url":"https://support.omadanetworks.com/en/document/108455/"},{"tags":["product"],"url":"https://www.omadanetworks.com/us/business-networking/all-omada-router/"},{"tags":["product"],"url":"https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"},{"tags":["product"],"url":"https://www.tp-link.com/us/business-networking/soho-festa-gateway/"}],"source":{"discovery":"UNKNOWN"},"title":"OS command injection using information obtained from the web management interface","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"f23511db-6c3e-4e32-a477-6aa17d310630","assignerShortName":"TPLink","cveId":"CVE-2025-6541","datePublished":"2025-10-21T00:21:42.535Z","dateReserved":"2025-06-23T17:48:07.425Z","dateUpdated":"2025-10-21T13:57:51.728Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2025-10-21 01:15:36","lastModifiedDate":"2026-06-17 10:02:06","problem_types":["CWE-78","CWE-78 CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"],"metrics":{"cvssMetricV40":[{"source":"f23511db-6c3e-4e32-a477-6aa17d310630","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-10-21T13:56:36.534414Z","id":"CVE-2025-6541","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.1","matchCriteriaId":"47273FE0-6E22-437E-B27F-058456E7602A"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*","matchCriteriaId":"AC30DFD7-30FD-482C-B8EF-9DDB98E269BF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*","matchCriteriaId":"7D599C4B-4A58-45EC-BA17-332FBF6E9805"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.1","matchCriteriaId":"E1BC6D9F-A556-468A-8770-6A39F09F26D6"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*","matchCriteriaId":"96944BD2-388F-4CF6-BFD3-473EE6624F74"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*","matchCriteriaId":"559FA8D2-3055-41CB-81A4-A7996D93588D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.3","matchCriteriaId":"6CE877B8-E287-4FE6-84D5-666FE27AC9A6"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*","matchCriteriaId":"24860FF1-7CA9-47D4-90B6-CB8915F1D992"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*","matchCriteriaId":"F300A161-E1A3-469E-9DE3-9B052F6BA8AC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.1.4","matchCriteriaId":"EB884461-7A80-44B0-A200-25D7E0EB5152"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*","matchCriteriaId":"BDA7D066-8443-4D6F-8E22-A0845236B490"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*","matchCriteriaId":"153073B7-9FBD-47D0-A1AB-CEE323AE5512"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.2","matchCriteriaId":"E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*","matchCriteriaId":"5FF584E3-70F0-4B05-857B-CE07D87BA130"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*","matchCriteriaId":"D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.1.10","matchCriteriaId":"D38B9DBD-3397-40B8-B4A5-C1E0C248C300"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*","matchCriteriaId":"4DA30139-EBED-40FD-BA20-CED14607B648"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*","matchCriteriaId":"DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.3","matchCriteriaId":"D7FC1549-BC5C-45CF-8524-6DFFB4193D1B"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*","matchCriteriaId":"532C5C8D-3AC4-4596-8D8C-6855686BD92A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*","matchCriteriaId":"56799602-9EF3-47D5-86CC-9AA2AE3013CF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.5","matchCriteriaId":"6952617F-CF3F-4EB4-89B3-0C7076EEEEBC"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*","matchCriteriaId":"5FDFE511-0244-454D-8D3F-C7E46D499FC5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*","matchCriteriaId":"2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.3","matchCriteriaId":"EE0D8327-33EE-4EF0-BC2F-F2A16D55762A"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*","matchCriteriaId":"6DB13EF6-0930-4575-92DC-AF431B2A2CEF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*","matchCriteriaId":"4F2F16D8-5D7B-4E01-8BB3-F324B6011F72"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.1.0","matchCriteriaId":"14CE8275-E546-4598-901C-F52355DED3C9"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*","matchCriteriaId":"B79E0763-6D6F-4E59-91FC-D397A8BEF0F1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*","matchCriteriaId":"FBB89DAE-6264-4F26-B34A-E1B84FB927D4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.1","matchCriteriaId":"48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*","matchCriteriaId":"359ADA2C-F1A5-4840-8F84-2DBA8F4573C4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*","matchCriteriaId":"E45AF81F-1346-4FD8-9E38-CAB330D79AB6"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.2.2","matchCriteriaId":"AF595A8A-72CF-406E-BB0C-B76FDD51150B"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*","matchCriteriaId":"8F66B05E-0D03-4B59-BCA3-7A2F40F092EE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*","matchCriteriaId":"EB65324D-FD72-4C28-92AF-85BFF1E8A993"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.3.1","matchCriteriaId":"8EA51B29-39FB-4880-979B-3F612DE9D202"},{"vulnerable":true,"criteria":"cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*","matchCriteriaId":"1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*","matchCriteriaId":"9892BC7C-6EA7-469B-AD26-6E5093DB5AB2"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"6541","Ordinal":"1","Title":"OS command injection using information obtained from the web man","CVE":"CVE-2025-6541","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"6541","Ordinal":"1","NoteData":"An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.","Type":"Description","Title":"OS command injection using information obtained from the web man"}]}}}