{"api_version":"1","generated_at":"2026-07-12T10:04:22+00:00","cve":"CVE-2025-65828","urls":{"html":"https://cve.report/CVE-2025-65828","api":"https://cve.report/api/cve/CVE-2025-65828.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-65828","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-65828"},"summary":{"title":"CVE-2025-65828","description":"An unauthenticated attacker within proximity of the Meatmeet device can issue several commands over Bluetooth Low Energy (BLE) to these devices which would result in a Denial of Service. These commands include: shutdown, restart, clear config. Clear config would disassociate the current device from its user and would require re-configuration to re-enable the device. As a result, the end user would be unable to receive updates from the Meatmeet base station which communicates with the cloud services until the device had been fixed or turned back on.","state":"PUBLISHED","assigner":"mitre","published_at":"2025-12-10 21:16:08","updated_at":"2026-07-05 02:17:28"},"problem_types":["CWE-306","n/a","CWE-306 CWE-306 Missing Authentication for Critical Function"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}}],"references":[{"url":"https://gist.github.com/dead1nfluence/4dffc239b4a460f41a03345fd8e5feb5#file-denial-of-service-ble-md","name":"https://gist.github.com/dead1nfluence/4dffc239b4a460f41a03345fd8e5feb5#file-denial-of-service-ble-md","refsource":"cve@mitre.org","tags":["Exploit","Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-65828","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-65828","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2025","cve_id":"65828","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"meatmeet","cpe5":"meatmeet_pro_wifi_\\&_bluetooth_meat_thermometer","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2025","cve_id":"65828","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"meatmeet","cpe5":"meatmeet_pro_wifi_\\&_bluetooth_meat_thermometer_firmware","cpe6":"1.0.34.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"65828","cve":"CVE-2025-65828","epss":"0.002480000","percentile":"0.159130000","score_date":"2026-07-08","updated_at":"2026-07-09 00:13:16"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},{"other":{"content":{"id":"CVE-2025-65828","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-12-18T20:28:29.956286Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306 Missing Authentication for Critical Function","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2025-12-18T20:28:35.546Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"An unauthenticated attacker within proximity of the Meatmeet device can issue several commands over Bluetooth Low Energy (BLE) to these devices which would result in a Denial of Service. These commands include: shutdown, restart, clear config. Clear config would disassociate the current device from its user and would require re-configuration to re-enable the device. As a result, the end user would be unable to receive updates from the Meatmeet base station which communicates with the cloud services until the device had been fixed or turned back on."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2026-07-05T01:24:04.484Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"url":"https://gist.github.com/dead1nfluence/4dffc239b4a460f41a03345fd8e5feb5#file-denial-of-service-ble-md"}]}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2025-65828","datePublished":"2025-12-10T00:00:00.000Z","dateReserved":"2025-11-18T00:00:00.000Z","dateUpdated":"2026-07-05T01:24:04.484Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-12-10 21:16:08","lastModifiedDate":"2026-07-05 02:17:28","problem_types":["CWE-306","n/a","CWE-306 CWE-306 Missing Authentication for Critical Function"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-12-18T20:28:29.956286Z","id":"CVE-2025-65828","options":[{"exploitation":"poc"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:meatmeet:meatmeet_pro_wifi_\\&_bluetooth_meat_thermometer_firmware:1.0.34.4:*:*:*:*:*:*:*","matchCriteriaId":"9B669DA2-CF06-461F-B624-DCD0359D1656"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:meatmeet:meatmeet_pro_wifi_\\&_bluetooth_meat_thermometer:-:*:*:*:*:*:*:*","matchCriteriaId":"1661B540-36E1-4BF0-BC63-9EC952560B54"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"65828","Ordinal":"1","Title":"CVE-2025-65828","CVE":"CVE-2025-65828","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"65828","Ordinal":"1","NoteData":"An unauthenticated attacker within proximity of the Meatmeet device can issue several commands over Bluetooth Low Energy (BLE) to these devices which would result in a Denial of Service. These commands include: shutdown, restart, clear config. Clear config would disassociate the current device from its user and would require re-configuration to re-enable the device. As a result, the end user would be unable to receive updates from the Meatmeet base station which communicates with the cloud services until the device had been fixed or turned back on.","Type":"Description","Title":"CVE-2025-65828"}]}}}