{"api_version":"1","generated_at":"2026-07-09T14:38:12+00:00","cve":"CVE-2025-67399","urls":{"html":"https://cve.report/CVE-2025-67399","api":"https://cve.report/api/cve/CVE-2025-67399.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-67399","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-67399"},"summary":{"title":"CVE-2025-67399","description":"An issue in AIRTH SMART HOME AQI MONITOR Bootloader v.1.005 allows a physically proximate attacker to obtain sensitive information via the UART port of the BK7231N controller (Wi-Fi and BLE module) on the device is open to access","state":"PUBLISHED","assigner":"mitre","published_at":"2026-01-14 16:15:56","updated_at":"2026-07-05 02:17:35"},"problem_types":["CWE-200","n/a","CWE-200 CWE-200 Exposure of Sensitive Information to an Unauthorized Actor"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"4.6","severity":"MEDIUM","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"NONE","baseScore":4.6,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"4.6","severity":"MEDIUM","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":4.6,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}}],"references":[{"url":"https://github.com/rupeshsurve04/CVE-2025-67399/blob/main/AIRTH_SMART_HOME_AQI_MONITOR_CVE-2025-67399.pdf","name":"https://github.com/rupeshsurve04/CVE-2025-67399/blob/main/AIRTH_SMART_HOME_AQI_MONITOR_CVE-2025-67399.pdf","refsource":"cve@mitre.org","tags":["Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-67399","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-67399","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2025","cve_id":"67399","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"airth","cpe5":"smart_home_aqi_monitor_bootloader","cpe6":"1.005","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"67399","cve":"CVE-2025-67399","epss":"0.001480000","percentile":"0.043860000","score_date":"2026-07-08","updated_at":"2026-07-09 00:13:16"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"NONE","baseScore":4.6,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}},{"other":{"content":{"id":"CVE-2025-67399","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-01-14T16:08:15.105569Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-200","description":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-01-14T16:09:43.888Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"An issue in AIRTH SMART HOME AQI MONITOR Bootloader v.1.005 allows a physically proximate attacker to obtain sensitive information via the UART port of the BK7231N controller (Wi-Fi and BLE module) on the device is open to access"}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2026-07-05T01:26:52.267Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"url":"https://github.com/rupeshsurve04/CVE-2025-67399/blob/main/AIRTH_SMART_HOME_AQI_MONITOR_CVE-2025-67399.pdf"}]}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2025-67399","datePublished":"2026-01-14T00:00:00.000Z","dateReserved":"2025-12-08T00:00:00.000Z","dateUpdated":"2026-07-05T01:26:52.267Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-01-14 16:15:56","lastModifiedDate":"2026-07-05 02:17:35","problem_types":["CWE-200","n/a","CWE-200 CWE-200 Exposure of Sensitive Information to an Unauthorized Actor"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":4.6,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-01-14T16:08:15.105569Z","id":"CVE-2025-67399","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:airth:smart_home_aqi_monitor_bootloader:1.005:*:*:*:*:*:*:*","matchCriteriaId":"C9D00FAD-24F7-472F-AF47-009F0010BFA4"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"67399","Ordinal":"1","Title":"CVE-2025-67399","CVE":"CVE-2025-67399","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"67399","Ordinal":"1","NoteData":"An issue in AIRTH SMART HOME AQI MONITOR Bootloader v.1.005 allows a physically proximate attacker to obtain sensitive information via the UART port of the BK7231N controller (Wi-Fi and BLE module) on the device is open to access","Type":"Description","Title":"CVE-2025-67399"}]}}}