{"api_version":"1","generated_at":"2026-05-27T21:11:38+00:00","cve":"CVE-2025-9231","urls":{"html":"https://cve.report/CVE-2025-9231","api":"https://cve.report/api/cve/CVE-2025-9231.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2025-9231","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2025-9231"},"summary":{"title":"Timing side-channel in SM2 algorithm on 64 bit ARM","description":"Issue summary: A timing side-channel which could potentially allow remote\nrecovery of the private key exists in the SM2 algorithm implementation on 64 bit\nARM platforms.\n\nImpact summary: A timing side-channel in SM2 signature computations on 64 bit\nARM platforms could allow recovering the private key by an attacker..\n\nWhile remote key recovery over a network was not attempted by the reporter,\ntiming measurements revealed a timing signal which may allow such an attack.\n\nOpenSSL does not directly support certificates with SM2 keys in TLS, and so\nthis CVE is not relevant in most TLS contexts.  However, given that it is\npossible to add support for such certificates via a custom provider, coupled\nwith the fact that in such a custom provider context the private key may be\nrecoverable via remote timing measurements, we consider this to be a Moderate\nseverity issue.\n\nThe FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this\nissue, as SM2 is not an approved algorithm.","state":"PUBLISHED","assigner":"openssl","published_at":"2025-09-30 14:15:41","updated_at":"2026-05-12 13:17:29"},"problem_types":["CWE-385","CWE-385 CWE-385 Covert Timing Channel"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"LOW"}}],"references":[{"url":"http://www.openwall.com/lists/oss-security/2026/05/11/11","name":"http://www.openwall.com/lists/oss-security/2026/05/11/11","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/openssl/openssl/commit/cba616c26ac8e7b37de5e77762e505ba5ca51698","name":"https://github.com/openssl/openssl/commit/cba616c26ac8e7b37de5e77762e505ba5ca51698","refsource":"openssl-security@openssl.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://openssl-library.org/news/secadv/20250930.txt","name":"https://openssl-library.org/news/secadv/20250930.txt","refsource":"openssl-security@openssl.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"http://www.openwall.com/lists/oss-security/2025/09/30/5","name":"http://www.openwall.com/lists/oss-security/2025/09/30/5","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-032379.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-032379.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/openssl/openssl/commit/567f64386e43683888212226824b6a179885a0fe","name":"https://github.com/openssl/openssl/commit/567f64386e43683888212226824b6a179885a0fe","refsource":"openssl-security@openssl.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/openssl/openssl/commit/fc47a2ec078912b3e914fab5734535e76c4820c2","name":"https://github.com/openssl/openssl/commit/fc47a2ec078912b3e914fab5734535e76c4820c2","refsource":"openssl-security@openssl.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://github.com/openssl/openssl/commit/eed5adc9f969d77c94f213767acbb41ff923b6f4","name":"https://github.com/openssl/openssl/commit/eed5adc9f969d77c94f213767acbb41ff923b6f4","refsource":"openssl-security@openssl.org","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2025-9231","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-9231","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"OpenSSL","product":"OpenSSL","version":"affected 3.5.0 3.5.4 semver","platforms":[]},{"source":"CNA","vendor":"OpenSSL","product":"OpenSSL","version":"affected 3.4.0 3.4.3 semver","platforms":[]},{"source":"CNA","vendor":"OpenSSL","product":"OpenSSL","version":"affected 3.3.0 3.3.5 semver","platforms":[]},{"source":"CNA","vendor":"OpenSSL","product":"OpenSSL","version":"affected 3.2.0 3.2.6 semver","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"RUGGEDCOM RST2428P","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCH328","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCM324","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCM328","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XCM332","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 12xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 8xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 12xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 8xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 12xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 8xFO)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)","version":"affected V3.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SIMATIC CN 4100","version":"affected V5.0 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Stanislav Fort (Aisle Research)","lang":"en"},{"source":"CNA","value":"Stanislav Fort (Aisle Research)","lang":"en"},{"source":"CNA","value":"Tomas Mraz","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2025","cve_id":"9231","cve":"CVE-2025-9231","epss":"0.000210000","percentile":"0.061010000","score_date":"2026-05-12","updated_at":"2026-05-13 00:11:53"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","version":"3.1"}},{"other":{"content":{"id":"CVE-2025-9231","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-09-30T19:27:45.704985Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2025-09-30T19:28:28.380Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"},{"providerMetadata":{"dateUpdated":"2026-05-11T20:34:16.504Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"url":"http://www.openwall.com/lists/oss-security/2025/09/30/5"},{"url":"http://www.openwall.com/lists/oss-security/2026/05/11/11"}],"title":"CVE Program Container"},{"affected":[{"defaultStatus":"unknown","product":"RUGGEDCOM RST2428P","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCH328","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCM324","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCM328","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XCM332","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (230 V AC, 12xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (230 V AC, 8xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (24 V DC, 12xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (24 V DC, 8xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (2x230 V AC, 12xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (2x230 V AC, 8xFO)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)","vendor":"Siemens","versions":[{"lessThan":"V3.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SIMATIC CN 4100","vendor":"Siemens","versions":[{"lessThan":"V5.0","status":"affected","version":"0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-05-12T12:02:41.108Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-032379.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"OpenSSL","vendor":"OpenSSL","versions":[{"lessThan":"3.5.4","status":"affected","version":"3.5.0","versionType":"semver"},{"lessThan":"3.4.3","status":"affected","version":"3.4.0","versionType":"semver"},{"lessThan":"3.3.5","status":"affected","version":"3.3.0","versionType":"semver"},{"lessThan":"3.2.6","status":"affected","version":"3.2.0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"reporter","value":"Stanislav Fort (Aisle Research)"},{"lang":"en","type":"remediation developer","value":"Stanislav Fort (Aisle Research)"},{"lang":"en","type":"remediation developer","value":"Tomas Mraz"}],"datePublic":"2025-09-30T14:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Issue summary: A timing side-channel which could potentially allow remote<br>recovery of the private key exists in the SM2 algorithm implementation on 64 bit<br>ARM platforms.<br><br>Impact summary: A timing side-channel in SM2 signature computations on 64 bit<br>ARM platforms could allow recovering the private key by an attacker..<br><br>While remote key recovery over a network was not attempted by the reporter,<br>timing measurements revealed a timing signal which may allow such an attack.<br><br>OpenSSL does not directly support certificates with SM2 keys in TLS, and so<br>this CVE is not relevant in most TLS contexts.  However, given that it is<br>possible to add support for such certificates via a custom provider, coupled<br>with the fact that in such a custom provider context the private key may be<br>recoverable via remote timing measurements, we consider this to be a Moderate<br>severity issue.<br><br>The FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this<br>issue, as SM2 is not an approved algorithm."}],"value":"Issue summary: A timing side-channel which could potentially allow remote\nrecovery of the private key exists in the SM2 algorithm implementation on 64 bit\nARM platforms.\n\nImpact summary: A timing side-channel in SM2 signature computations on 64 bit\nARM platforms could allow recovering the private key by an attacker..\n\nWhile remote key recovery over a network was not attempted by the reporter,\ntiming measurements revealed a timing signal which may allow such an attack.\n\nOpenSSL does not directly support certificates with SM2 keys in TLS, and so\nthis CVE is not relevant in most TLS contexts.  However, given that it is\npossible to add support for such certificates via a custom provider, coupled\nwith the fact that in such a custom provider context the private key may be\nrecoverable via remote timing measurements, we consider this to be a Moderate\nseverity issue.\n\nThe FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this\nissue, as SM2 is not an approved algorithm."}],"metrics":[{"format":"other","other":{"content":{"text":"Moderate"},"type":"https://openssl-library.org/policies/general/security-policy/"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-385","description":"CWE-385 Covert Timing Channel","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2025-09-30T13:17:12.007Z","orgId":"3a12439a-ef3a-4c79-92e6-6081a721f1e5","shortName":"openssl"},"references":[{"name":"OpenSSL Advisory","tags":["vendor-advisory"],"url":"https://openssl-library.org/news/secadv/20250930.txt"},{"name":"3.5.4 git commit","tags":["patch"],"url":"https://github.com/openssl/openssl/commit/fc47a2ec078912b3e914fab5734535e76c4820c2"},{"name":"3.4.3 git commit","tags":["patch"],"url":"https://github.com/openssl/openssl/commit/eed5adc9f969d77c94f213767acbb41ff923b6f4"},{"name":"3.3.5 git commit","tags":["patch"],"url":"https://github.com/openssl/openssl/commit/567f64386e43683888212226824b6a179885a0fe"},{"name":"3.2.6 git commit","tags":["patch"],"url":"https://github.com/openssl/openssl/commit/cba616c26ac8e7b37de5e77762e505ba5ca51698"}],"source":{"discovery":"UNKNOWN"},"title":"Timing side-channel in SM2 algorithm on 64 bit ARM","x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"3a12439a-ef3a-4c79-92e6-6081a721f1e5","assignerShortName":"openssl","cveId":"CVE-2025-9231","datePublished":"2025-09-30T13:17:12.007Z","dateReserved":"2025-08-20T08:38:09.832Z","dateUpdated":"2026-05-12T12:02:41.108Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2025-09-30 14:15:41","lastModifiedDate":"2026-05-12 13:17:29","problem_types":["CWE-385","CWE-385 CWE-385 Covert Timing Channel"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"LOW"},"exploitabilityScore":3.9,"impactScore":2.5}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2025","CveId":"9231","Ordinal":"1","Title":"Timing side-channel in SM2 algorithm on 64 bit ARM","CVE":"CVE-2025-9231","Year":"2025"},"notes":[{"CveYear":"2025","CveId":"9231","Ordinal":"1","NoteData":"Issue summary: A timing side-channel which could potentially allow remote\nrecovery of the private key exists in the SM2 algorithm implementation on 64 bit\nARM platforms.\n\nImpact summary: A timing side-channel in SM2 signature computations on 64 bit\nARM platforms could allow recovering the private key by an attacker..\n\nWhile remote key recovery over a network was not attempted by the reporter,\ntiming measurements revealed a timing signal which may allow such an attack.\n\nOpenSSL does not directly support certificates with SM2 keys in TLS, and so\nthis CVE is not relevant in most TLS contexts.  However, given that it is\npossible to add support for such certificates via a custom provider, coupled\nwith the fact that in such a custom provider context the private key may be\nrecoverable via remote timing measurements, we consider this to be a Moderate\nseverity issue.\n\nThe FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this\nissue, as SM2 is not an approved algorithm.","Type":"Description","Title":"Timing side-channel in SM2 algorithm on 64 bit ARM"}]}}}