{"api_version":"1","generated_at":"2026-10-22T01:49:02+00:00","cve":"CVE-2026-102076","urls":{"html":"https://cve.report/CVE-2026-102076","api":"https://cve.report/api/cve/CVE-2026-102076.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-102076","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-102076"},"summary":{"title":"CVE-2026-102076","description":"A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user-supplied input in upload code. This could allow an unauthenticated remote attacker to cause a denial of service.","state":"PUBLISHED","assigner":"siemens","published_at":"2026-10-13 10:17:14","updated_at":"2026-10-15 20:38:04"},"problem_types":["CWE-121","CWE-121 CWE-121: Stack-based Buffer Overflow"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"8.7","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","data":{"baseScore":8.7,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-333035.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-333035.html","refsource":"productcert@siemens.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-102076","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-102076","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"APOGEE MBC (PPC) (BACnet)","version":"affected * custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"APOGEE MBC (PPC) (P2 Ethernet)","version":"affected * custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"APOGEE MEC (PPC) (BACnet)","version":"affected * custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"APOGEE MEC (PPC) (P2 Ethernet)","version":"affected * custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"APOGEE PXC Compact (BACnet)","version":"affected V3.5.7 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"APOGEE PXC Compact (P2 Ethernet)","version":"affected V2.8.21 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"APOGEE PXC Modular (BACnet)","version":"affected V3.5.7 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"APOGEE PXC Modular (P2 Ethernet)","version":"affected V2.8.21 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"TALON TC Compact (BACnet)","version":"affected V3.5.7 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"TALON TC Modular (BACnet)","version":"affected V3.5.7 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"102076","cve":"CVE-2026-102076","epss":"0.005730000","percentile":"0.461240000","score_date":"2026-10-15","updated_at":"2026-10-16 00:06:12"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-102076","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-10-13T15:48:05.994494Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-10-13T16:20:06.658Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"APOGEE MBC (PPC) (BACnet)","vendor":"Siemens","versions":[{"lessThan":"*","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"APOGEE MBC (PPC) (P2 Ethernet)","vendor":"Siemens","versions":[{"lessThan":"*","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"APOGEE MEC (PPC) (BACnet)","vendor":"Siemens","versions":[{"lessThan":"*","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"APOGEE MEC (PPC) (P2 Ethernet)","vendor":"Siemens","versions":[{"lessThan":"*","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"APOGEE PXC Compact (BACnet)","vendor":"Siemens","versions":[{"lessThan":"V3.5.7","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"APOGEE PXC Compact (P2 Ethernet)","vendor":"Siemens","versions":[{"lessThan":"V2.8.21","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"APOGEE PXC Modular (BACnet)","vendor":"Siemens","versions":[{"lessThan":"V3.5.7","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"APOGEE PXC Modular (P2 Ethernet)","vendor":"Siemens","versions":[{"lessThan":"V2.8.21","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"TALON TC Compact (BACnet)","vendor":"Siemens","versions":[{"lessThan":"V3.5.7","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"TALON TC Modular (BACnet)","vendor":"Siemens","versions":[{"lessThan":"V3.5.7","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user-supplied input in upload code. This could allow an unauthenticated remote attacker to cause a denial of service."}],"metrics":[{"cvssV3_1":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},{"cvssV4_0":{"baseScore":8.7,"baseSeverity":"HIGH","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","description":"CWE-121: Stack-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-10-13T09:19:16.853Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-333035.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2026-102076","datePublished":"2026-10-13T09:19:16.853Z","dateReserved":"2026-09-28T17:37:23.338Z","dateUpdated":"2026-10-13T16:20:06.658Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-10-13 10:17:14","lastModifiedDate":"2026-10-15 20:38:04","problem_types":["CWE-121","CWE-121 CWE-121: Stack-based Buffer Overflow"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-10-13T15:48:05.994494Z","id":"CVE-2026-102076","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"102076","Ordinal":"1","Title":"CVE-2026-102076","CVE":"CVE-2026-102076","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"102076","Ordinal":"1","NoteData":"A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user-supplied input in upload code. This could allow an unauthenticated remote attacker to cause a denial of service.","Type":"Description","Title":"CVE-2026-102076"}]}}}