{"api_version":"1","generated_at":"2026-11-13T07:55:00+00:00","cve":"CVE-2026-114031","urls":{"html":"https://cve.report/CVE-2026-114031","api":"https://cve.report/api/cve/CVE-2026-114031.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-114031","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-114031"},"summary":{"title":"Local privilege escalation via insecure folder permissions","description":"Incorrect permission assignment allows local privilege escalation to SYSTEM on affected releases of the Illumio VEN for Windows. Code execution as NT AUTHORITY\\LOCAL SERVICE on the Windows host is required to exploit this vulnerability. The flaw exists within the VEN installer, which grants LOCAL SERVICE full access to the VEN data and installation folders, whose configuration and state files are read and trusted by the SYSTEM-privileged illumio-ven-ctl component. An attacker can leverage this vulnerability to modify the VEN configuration so that illumio-ven-ctl executes an injected command in the context of the SYSTEM account.","state":"PUBLISHED","assigner":"Illumio","published_at":"2026-11-09 22:18:27","updated_at":"2026-11-12 22:09:39"},"problem_types":["CWE-732","CWE-732 CWE-732 Incorrect permission assignment for critical resource"],"metrics":[{"version":"3.1","source":"security@illumio.com","type":"Secondary","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.8","severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://product-docs-repo.illumio.com/Tech-Docs/Security+Advisories/out/en/security-advisories/insecure-folder-permissions-in-the-windows-ven.html","name":"https://product-docs-repo.illumio.com/Tech-Docs/Security+Advisories/out/en/security-advisories/insecure-folder-permissions-in-the-windows-ven.html","refsource":"security@illumio.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-114031","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-114031","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 26.2.12 26.2.12-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 25.2.41 25.2.41-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 25.2.40 25.2.40-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 25.2.31 25.2.31-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 25.2.20 25.2.20-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 25.2.10 25.2.10-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 24.2.40 24.2.40-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 24.2.35 24.2.35-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 24.2.30 24.2.30-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 24.2.20 24.2.20-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 24.2.11 24.2.11-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 24.2.10 24.2.10-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.31 23.2.31-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.31-LA 23.2.31-LA-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.30 23.2.30-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.24 23.2.24-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.24-LA 23.2.24-LA-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.23 23.2.23-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.22 23.2.22-S1 semver","platforms":["Windows"]},{"source":"CNA","vendor":"Illumio","product":"Core Ven","version":"affected 23.2.22-LA 23.2.22-LA-S1 semver","platforms":["Windows"]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"114031","cve":"CVE-2026-114031","epss":"0.001020000","percentile":"0.009160000","score_date":"2026-11-12","updated_at":"2026-11-13 00:14:34"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-114031","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-11-12T17:10:35.342224Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-11-12T17:11:30.616Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","platforms":["Windows"],"product":"Core Ven","vendor":"Illumio","versions":[{"lessThan":"26.2.12-S1","status":"affected","version":"26.2.12","versionType":"semver"},{"lessThan":"25.2.41-S1","status":"affected","version":"25.2.41","versionType":"semver"},{"lessThan":"25.2.40-S1","status":"affected","version":"25.2.40","versionType":"semver"},{"lessThan":"25.2.31-S1","status":"affected","version":"25.2.31","versionType":"semver"},{"lessThan":"25.2.20-S1","status":"affected","version":"25.2.20","versionType":"semver"},{"lessThan":"25.2.10-S1","status":"affected","version":"25.2.10","versionType":"semver"},{"lessThan":"24.2.40-S1","status":"affected","version":"24.2.40","versionType":"semver"},{"lessThan":"24.2.35-S1","status":"affected","version":"24.2.35","versionType":"semver"},{"lessThan":"24.2.30-S1","status":"affected","version":"24.2.30","versionType":"semver"},{"lessThan":"24.2.20-S1","status":"affected","version":"24.2.20","versionType":"semver"},{"lessThan":"24.2.11-S1","status":"affected","version":"24.2.11","versionType":"semver"},{"lessThan":"24.2.10-S1","status":"affected","version":"24.2.10","versionType":"semver"},{"lessThan":"23.2.31-S1","status":"affected","version":"23.2.31","versionType":"semver"},{"lessThan":"23.2.31-LA-S1","status":"affected","version":"23.2.31-LA","versionType":"semver"},{"lessThan":"23.2.30-S1","status":"affected","version":"23.2.30","versionType":"semver"},{"lessThan":"23.2.24-S1","status":"affected","version":"23.2.24","versionType":"semver"},{"lessThan":"23.2.24-LA-S1","status":"affected","version":"23.2.24-LA","versionType":"semver"},{"lessThan":"23.2.23-S1","status":"affected","version":"23.2.23","versionType":"semver"},{"lessThan":"23.2.22-S1","status":"affected","version":"23.2.22","versionType":"semver"},{"lessThan":"23.2.22-LA-S1","status":"affected","version":"23.2.22-LA","versionType":"semver"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Incorrect permission assignment allows local privilege escalation to SYSTEM on affected releases of the Illumio VEN for Windows. Code execution as NT AUTHORITY\\LOCAL SERVICE on the Windows host is required to exploit this vulnerability. The flaw exists within the VEN installer, which grants LOCAL SERVICE full access to the VEN data and installation folders, whose configuration and state files are read and trusted by the SYSTEM-privileged illumio-ven-ctl component. An attacker can leverage this vulnerability to modify the VEN configuration so that illumio-ven-ctl executes an injected command in the context of the SYSTEM account.<br>"}],"value":"Incorrect permission assignment allows local privilege escalation to SYSTEM on affected releases of the Illumio VEN for Windows. Code execution as NT AUTHORITY\\LOCAL SERVICE on the Windows host is required to exploit this vulnerability. The flaw exists within the VEN installer, which grants LOCAL SERVICE full access to the VEN data and installation folders, whose configuration and state files are read and trusted by the SYSTEM-privileged illumio-ven-ctl component. An attacker can leverage this vulnerability to modify the VEN configuration so that illumio-ven-ctl executes an injected command in the context of the SYSTEM account."}],"impacts":[{"capecId":"CAPEC-17","descriptions":[{"lang":"en","value":"CAPEC-17 Using Malicious Files"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-732","description":"CWE-732 Incorrect permission assignment for critical resource","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-10T19:16:07.428Z","orgId":"ea070963-4842-4451-bceb-906a17f8dc69","shortName":"Illumio"},"references":[{"tags":["vendor-advisory"],"url":"https://product-docs-repo.illumio.com/Tech-Docs/Security+Advisories/out/en/security-advisories/insecure-folder-permissions-in-the-windows-ven.html"}],"source":{"discovery":"UNKNOWN"},"title":"Local privilege escalation via insecure folder permissions","x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"ea070963-4842-4451-bceb-906a17f8dc69","assignerShortName":"Illumio","cveId":"CVE-2026-114031","datePublished":"2026-11-09T21:31:15.467Z","dateReserved":"2026-10-20T21:11:53.061Z","dateUpdated":"2026-11-12T17:11:30.616Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-09 22:18:27","lastModifiedDate":"2026-11-12 22:09:39","problem_types":["CWE-732","CWE-732 CWE-732 Incorrect permission assignment for critical resource"],"metrics":{"cvssMetricV31":[{"source":"security@illumio.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-11-12T17:10:35.342224Z","id":"CVE-2026-114031","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"114031","Ordinal":"1","Title":"Local privilege escalation via insecure folder permissions","CVE":"CVE-2026-114031","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"114031","Ordinal":"1","NoteData":"Incorrect permission assignment allows local privilege escalation to SYSTEM on affected releases of the Illumio VEN for Windows. Code execution as NT AUTHORITY\\LOCAL SERVICE on the Windows host is required to exploit this vulnerability. The flaw exists within the VEN installer, which grants LOCAL SERVICE full access to the VEN data and installation folders, whose configuration and state files are read and trusted by the SYSTEM-privileged illumio-ven-ctl component. An attacker can leverage this vulnerability to modify the VEN configuration so that illumio-ven-ctl executes an injected command in the context of the SYSTEM account.","Type":"Description","Title":"Local privilege escalation via insecure folder permissions"}]}}}