{"api_version":"1","generated_at":"2026-10-23T08:13:02+00:00","cve":"CVE-2026-114625","urls":{"html":"https://cve.report/CVE-2026-114625","api":"https://cve.report/api/cve/CVE-2026-114625.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-114625","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-114625"},"summary":{"title":"Security Advisory 0199","description":"VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.\n\nOn an affected system, any authenticated user can gain operator privileges and masquerade as a local \"superuser operator\" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.\n\nHosted, including Dedicated, versions of VCO were impacted and have already been patched.","state":"PUBLISHED","assigner":"Arista","published_at":"2026-10-22 21:17:16","updated_at":"2026-10-23 04:18:13"},"problem_types":["CWE-89","CWE-89 CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"],"metrics":[{"version":"4.0","source":"psirt@arista.com","type":"Secondary","score":"9.4","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.4,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"9.4","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","data":{"baseScore":9.4,"baseSeverity":"CRITICAL","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"}},{"version":"3.1","source":"psirt@arista.com","type":"Secondary","score":"9.9","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"9.9","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","data":{"baseScore":9.9,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}}],"references":[{"url":"https://www.arista.com/en/support/advisories-notices/security-advisory/24838-security-advisory-0199","name":"https://www.arista.com/en/support/advisories-notices/security-advisory/24838-security-advisory-0199","refsource":"psirt@arista.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-114625","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-114625","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Arista Networks","product":"VeloCloud Orchestrator","version":"affected 5.2.0 5.2.3.18 custom","platforms":["VeloCloud Orchestrator On-Prem"]},{"source":"CNA","vendor":"Arista Networks","product":"VeloCloud Orchestrator","version":"affected 6.1.0 6.1.3.10 custom","platforms":["VeloCloud Orchestrator On-Prem"]},{"source":"CNA","vendor":"Arista Networks","product":"VeloCloud Orchestrator","version":"affected 6.4.0 6.4.2.12 custom","platforms":["VeloCloud Orchestrator On-Prem"]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"The recommended resolution is to upgrade to a fixed VCO release at your earliest convenience.\n\nThese vulnerabilities have been fixed in the following releases:\n\n- VCO 5.2.3.18 and later in the 5.2 train\n- VCO 6.1.3.10 and later in the 6.1 train\n- VCO 6.4.2.12 and later in the 6.4 train","time":"","lang":"en"}],"workarounds":[{"source":"CNA","title":"","value":"Until the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment:\n\n- Restrict access to the VCO web interface to trusted administrative networks.\n- Monitor the VCO for accesses from known malicious source IPs.\n- Monitor for unexpected outbound network activity from the VCO host.\n- Consider blocking outbound ports not needed for normal activities.\n- Monitor for backdoor daemons and webshells.\n- Review recent administrator activity for unexpected changes.","time":"","lang":"en"}],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-114625","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-10-22T00:00:00+00:00","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-10-23T03:55:37.265Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","platforms":["VeloCloud Orchestrator On-Prem"],"product":"VeloCloud Orchestrator","vendor":"Arista Networks","versions":[{"lessThan":"5.2.3.18","status":"affected","version":"5.2.0","versionType":"custom"},{"lessThan":"6.1.3.10","status":"affected","version":"6.1.0","versionType":"custom"},{"lessThan":"6.4.2.12","status":"affected","version":"6.4.0","versionType":"custom"}]}],"configurations":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>VCO is exposed by default. A successful attack requires network access to the VCO web interface and a valid authenticated session on the VCO portal. The minimum user role required is <strong>Enterprise Read Only</strong>, the lowest built-in tenant role. There is no configuration that can prevent the exposure.</p>"}],"value":"VCO is exposed by default. A successful attack requires network access to the VCO web interface and a valid authenticated session on the VCO portal. The minimum user role required is Enterprise Read Only, the lowest built-in tenant role. There is no configuration that can prevent the exposure."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.</p><p>On an affected system, any authenticated user can gain operator privileges and masquerade as a local &quot;superuser operator&quot; user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.</p><p>Hosted, including Dedicated, versions of VCO were impacted and have already been patched.</p>"}],"value":"VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.\n\nOn an affected system, any authenticated user can gain operator privileges and masquerade as a local \"superuser operator\" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.\n\nHosted, including Dedicated, versions of VCO were impacted and have already been patched."}],"impacts":[{"capecId":"CAPEC-66","descriptions":[{"lang":"en","value":"CAPEC-66 SQL Injection"}]}],"metrics":[{"cvssV3_1":{"baseScore":9.9,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"baseScore":9.4,"baseSeverity":"CRITICAL","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-89","description":"CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-10-22T20:47:56.427Z","orgId":"c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7","shortName":"Arista"},"references":[{"name":"Security Advisory 0199","tags":["vendor-advisory"],"url":"https://www.arista.com/en/support/advisories-notices/security-advisory/24838-security-advisory-0199"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>The recommended resolution is to upgrade to a fixed VCO release at your earliest convenience.</p><p>These vulnerabilities have been fixed in the following releases:</p><ul><li>VCO <strong>5.2.3.18</strong> and later in the 5.2 train</li><li>VCO <strong>6.1.3.10</strong> and later in the 6.1 train</li><li>VCO <strong>6.4.2.12</strong> and later in the 6.4 train</li></ul>"}],"value":"The recommended resolution is to upgrade to a fixed VCO release at your earliest convenience.\n\nThese vulnerabilities have been fixed in the following releases:\n\n- VCO 5.2.3.18 and later in the 5.2 train\n- VCO 6.1.3.10 and later in the 6.1 train\n- VCO 6.4.2.12 and later in the 6.4 train"}],"source":{"advisory":"Security Advisory 0199","defects":["BUG2043622"],"discovery":"EXTERNAL"},"title":"Security Advisory 0199","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Until the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment:</p><ul><li>Restrict access to the VCO web interface to trusted administrative networks.</li><li>Monitor the VCO for accesses from known malicious source IPs.</li><li>Monitor for unexpected outbound network activity from the VCO host.</li><li>Consider blocking outbound ports not needed for normal activities.</li><li>Monitor for backdoor daemons and webshells.</li><li>Review recent administrator activity for unexpected changes.</li></ul>"}],"value":"Until the fixed software is deployed, operators should apply defense-in-depth controls appropriate for their environment:\n\n- Restrict access to the VCO web interface to trusted administrative networks.\n- Monitor the VCO for accesses from known malicious source IPs.\n- Monitor for unexpected outbound network activity from the VCO host.\n- Consider blocking outbound ports not needed for normal activities.\n- Monitor for backdoor daemons and webshells.\n- Review recent administrator activity for unexpected changes."}]}},"cveMetadata":{"assignerOrgId":"c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7","assignerShortName":"Arista","cveId":"CVE-2026-114625","datePublished":"2026-10-22T20:47:56.427Z","dateReserved":"2026-10-21T20:35:35.535Z","dateUpdated":"2026-10-23T03:55:37.265Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-10-22 21:17:16","lastModifiedDate":"2026-10-23 04:18:13","problem_types":["CWE-89","CWE-89 CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"],"metrics":{"cvssMetricV40":[{"source":"psirt@arista.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.4,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"psirt@arista.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.1,"impactScore":6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-10-22T00:00:00+00:00","id":"CVE-2026-114625","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"114625","Ordinal":"1","Title":"Security Advisory 0199","CVE":"CVE-2026-114625","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"114625","Ordinal":"1","NoteData":"VeloCloud Orchestrator (VCO) on-prem has a security issue where this issue may allow a remote attacker to access privileged internal functionality and impact the VCO host. Successful exploitation may compromise the confidentiality, integrity, and availability of the orchestrator and data managed by the orchestrator.\n\nOn an affected system, any authenticated user can gain operator privileges and masquerade as a local \"superuser operator\" user. This includes access to functionality that is intended for internal use only and which is not intended to be remotely accessible.\n\nHosted, including Dedicated, versions of VCO were impacted and have already been patched.","Type":"Description","Title":"Security Advisory 0199"}]}}}