{"api_version":"1","generated_at":"2026-10-29T03:48:47+00:00","cve":"CVE-2026-118608","urls":{"html":"https://cve.report/CVE-2026-118608","api":"https://cve.report/api/cve/CVE-2026-118608.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-118608","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-118608"},"summary":{"title":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability","description":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Alpine iLX-F511 devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the prh_rfcomm_cc_process_test function. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-29018.","state":"PUBLISHED","assigner":"zdi","published_at":"2026-10-28 17:18:27","updated_at":"2026-10-28 17:18:27"},"problem_types":["CWE-125","CWE-125 CWE-125: Out-of-bounds Read"],"metrics":[{"version":"3.0","source":"zdi-disclosures@trendmicro.com","type":"Secondary","score":"3.5","severity":"LOW","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","baseScore":3.5,"baseSeverity":"LOW","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.0","source":"CNA","type":"CVSS","score":"3.5","severity":"LOW","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","data":{"baseScore":3.5,"baseSeverity":"LOW","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","version":"3.0"}}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-826/","name":"https://www.zerodayinitiative.com/advisories/ZDI-26-826/","refsource":"zdi-disclosures@trendmicro.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-118608","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-118608","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Alpine","product":"iLX-F511","version":"affected 7.0.000","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unknown","product":"iLX-F511","vendor":"Alpine","versions":[{"status":"affected","version":"7.0.000"}]}],"dateAssigned":"2026-10-28T16:49:08.401Z","datePublic":"2026-10-28T16:44:59.618Z","descriptions":[{"lang":"en","value":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Alpine iLX-F511 devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the prh_rfcomm_cc_process_test function. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-29018."}],"metrics":[{"cvssV3_0":{"baseScore":3.5,"baseSeverity":"LOW","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","version":"3.0"},"format":"CVSS"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","description":"CWE-125: Out-of-bounds Read","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-10-28T16:50:34.964Z","orgId":"99f1926a-a320-47d8-bbb5-42feb611262e","shortName":"zdi"},"references":[{"name":"ZDI-26-826","tags":["x_research-advisory"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-826/"}],"source":{"lang":"en","value":"Dong hee Kim and Jong geon Kim from team K"},"title":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability"}},"cveMetadata":{"assignerOrgId":"99f1926a-a320-47d8-bbb5-42feb611262e","assignerShortName":"zdi","cveId":"CVE-2026-118608","datePublished":"2026-10-28T16:50:34.964Z","dateReserved":"2026-10-28T16:49:08.374Z","dateUpdated":"2026-10-28T16:50:34.964Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-10-28 17:18:27","lastModifiedDate":"2026-10-28 17:18:27","problem_types":["CWE-125","CWE-125 CWE-125: Out-of-bounds Read"],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","baseScore":3.5,"baseSeverity":"LOW","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.1,"impactScore":1.4}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"118608","Ordinal":"1","Title":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-","CVE":"CVE-2026-118608","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"118608","Ordinal":"1","NoteData":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Alpine iLX-F511 devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the prh_rfcomm_cc_process_test function. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-29018.","Type":"Description","Title":"Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-"}]}}}