{"api_version":"1","generated_at":"2026-11-13T00:01:39+00:00","cve":"CVE-2026-118632","urls":{"html":"https://cve.report/CVE-2026-118632","api":"https://cve.report/api/cve/CVE-2026-118632.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-118632","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-118632"},"summary":{"title":"Philips Hue Bridge Pro SQL Injection Remote Code Execution Vulnerability","description":"Philips Hue Bridge Pro SQL Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge Pro. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the HTTP service, which listens on TCP port 443 by default. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-33089.","state":"PUBLISHED","assigner":"zdi","published_at":"2026-11-12 03:17:10","updated_at":"2026-11-12 18:48:46"},"problem_types":["CWE-89","CWE-89 CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"],"metrics":[{"version":"3.0","source":"zdi-disclosures@trendmicro.com","type":"Secondary","score":"8","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.0","source":"CNA","type":"CVSS","score":"8","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","data":{"baseScore":8,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-891/","name":"https://www.zerodayinitiative.com/advisories/ZDI-26-891/","refsource":"zdi-disclosures@trendmicro.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-118632","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-118632","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Philips","product":"Hue Bridge Pro","version":"affected 2071026000","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unknown","product":"Hue Bridge Pro","vendor":"Philips","versions":[{"status":"affected","version":"2071026000"}]}],"dateAssigned":"2026-10-28T16:58:59.001Z","datePublic":"2026-11-06T22:17:28.151Z","descriptions":[{"lang":"en","value":"Philips Hue Bridge Pro SQL Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge Pro. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the HTTP service, which listens on TCP port 443 by default. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-33089."}],"metrics":[{"cvssV3_0":{"baseScore":8,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"format":"CVSS"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-89","description":"CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-12T02:52:15.303Z","orgId":"99f1926a-a320-47d8-bbb5-42feb611262e","shortName":"zdi"},"references":[{"name":"ZDI-26-891","tags":["x_research-advisory"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-891/"}],"source":{"lang":"en","value":"Connor Ford @ByteInsight of TrendAI Zero Day Initiative"},"title":"Philips Hue Bridge Pro SQL Injection Remote Code Execution Vulnerability"}},"cveMetadata":{"assignerOrgId":"99f1926a-a320-47d8-bbb5-42feb611262e","assignerShortName":"zdi","cveId":"CVE-2026-118632","datePublished":"2026-11-12T02:52:15.303Z","dateReserved":"2026-10-28T16:58:58.973Z","dateUpdated":"2026-11-12T02:52:15.303Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-12 03:17:10","lastModifiedDate":"2026-11-12 18:48:46","problem_types":["CWE-89","CWE-89 CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"118632","Ordinal":"1","Title":"Philips Hue Bridge Pro SQL Injection Remote Code Execution Vulne","CVE":"CVE-2026-118632","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"118632","Ordinal":"1","NoteData":"Philips Hue Bridge Pro SQL Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge Pro. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the HTTP service, which listens on TCP port 443 by default. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-33089.","Type":"Description","Title":"Philips Hue Bridge Pro SQL Injection Remote Code Execution Vulne"}]}}}