{"api_version":"1","generated_at":"2026-11-27T16:38:43+00:00","cve":"CVE-2026-123760","urls":{"html":"https://cve.report/CVE-2026-123760","api":"https://cve.report/api/cve/CVE-2026-123760.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-123760","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-123760"},"summary":{"title":"Logic flaw in LMDB backend can lead to an unresponsive server","description":"When using the LMDB backend, performing zone rectification when the number of Empty Non-Terminal entries is larger than the max-ent-entries setting triggers a logic bug and causes the PowerDNS process to spin with the LMDB database locked.","state":"PUBLISHED","assigner":"OX","published_at":"2026-11-27 14:17:01","updated_at":"2026-11-27 14:17:01"},"problem_types":["CWE-400","CWE-400 CWE-400 Uncontrolled Resource Consumption"],"metrics":[{"version":"3.1","source":"security@open-xchange.com","type":"Secondary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}}],"references":[{"url":"https://docs.powerdns.com/authoritative/security-advisories/powerdns-advisory-powerdns-2026-14.html","name":"https://docs.powerdns.com/authoritative/security-advisories/powerdns-advisory-powerdns-2026-14.html","refsource":"security@open-xchange.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-123760","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-123760","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"PowerDNS","product":"Authoritative","version":"affected 5.1.0 5.1.6 semver","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"mihaimacarie98","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"collectionURL":"https://repo.powerdns.com/","defaultStatus":"unaffected","modules":["LMDB backend"],"packageName":"pdns","product":"Authoritative","programFiles":["modules/lmdbbackend/lmdbbackend.cc"],"repo":"https://github.com/PowerDNS/pdns","vendor":"PowerDNS","versions":[{"lessThan":"5.1.6","status":"affected","version":"5.1.0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"mihaimacarie98"}],"datePublic":"2026-11-11T23:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>When using the LMDB backend, performing zone rectification when the number of Empty Non-Terminal entries is larger than the max-ent-entries setting triggers a logic bug and causes the PowerDNS process to spin with the LMDB database locked.</p>"}],"value":"When using the LMDB backend, performing zone rectification when the number of Empty Non-Terminal entries is larger than the max-ent-entries setting triggers a logic bug and causes the PowerDNS process to spin with the LMDB database locked."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-400","description":"CWE-400 Uncontrolled Resource Consumption","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-27T13:38:48.664Z","orgId":"8ce71d90-2354-404b-a86e-bec2cc4e6981","shortName":"OX"},"references":[{"url":"https://docs.powerdns.com/authoritative/security-advisories/powerdns-advisory-powerdns-2026-14.html"}],"source":{"advisory":"PowerDNS Security Advisory POWERDNS-2026-14","discovery":"EXTERNAL"},"title":"Logic flaw in LMDB backend can lead to an unresponsive server","x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"8ce71d90-2354-404b-a86e-bec2cc4e6981","assignerShortName":"OX","cveId":"CVE-2026-123760","datePublished":"2026-11-27T13:38:48.664Z","dateReserved":"2026-11-06T13:46:33.300Z","dateUpdated":"2026-11-27T13:38:48.664Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-27 14:17:01","lastModifiedDate":"2026-11-27 14:17:01","problem_types":["CWE-400","CWE-400 CWE-400 Uncontrolled Resource Consumption"],"metrics":{"cvssMetricV31":[{"source":"security@open-xchange.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"123760","Ordinal":"1","Title":"Logic flaw in LMDB backend can lead to an unresponsive server","CVE":"CVE-2026-123760","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"123760","Ordinal":"1","NoteData":"When using the LMDB backend, performing zone rectification when the number of Empty Non-Terminal entries is larger than the max-ent-entries setting triggers a logic bug and causes the PowerDNS process to spin with the LMDB database locked.","Type":"Description","Title":"Logic flaw in LMDB backend can lead to an unresponsive server"}]}}}