{"api_version":"1","generated_at":"2026-11-10T11:58:17+00:00","cve":"CVE-2026-124577","urls":{"html":"https://cve.report/CVE-2026-124577","api":"https://cve.report/api/cve/CVE-2026-124577.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-124577","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-124577"},"summary":{"title":"Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper authentication","description":"A weakness has been identified in Intelbras SG 2404 PoE L2+ 1.00.70/1.00.72. The affected element is an unknown function of the file /EXCU_SHELL of the component Web Management Interface. Executing a manipulation can lead to improper authentication. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 1.00.74 is sufficient to fix this issue. Upgrading the affected component is advised.","state":"PUBLISHED","assigner":"VulDB","published_at":"2026-11-09 08:17:02","updated_at":"2026-11-09 08:17:02"},"problem_types":["CWE-287","CWE-287 Improper Authentication"],"metrics":[{"version":"4.0","source":"cna@vuldb.com","type":"Secondary","score":"8.9","severity":"HIGH","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.9,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"PROOF_OF_CONCEPT","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"9.3","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","data":{"baseScore":9.3,"baseSeverity":"CRITICAL","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"}},{"version":"3.1","source":"cna@vuldb.com","type":"Primary","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","data":{"baseScore":9.8,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"}},{"version":"3.0","source":"CNA","type":"DECLARED","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","data":{"baseScore":9.8,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.0"}},{"version":"2.0","source":"cna@vuldb.com","type":"Secondary","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"}},{"version":"2.0","source":"CNA","type":"DECLARED","score":"10","severity":"","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:OF/RC:C","data":{"baseScore":10,"vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:OF/RC:C","version":"2.0"}}],"references":[{"url":"https://vuldb.com/submit/1038184","name":"https://vuldb.com/submit/1038184","refsource":"cna@vuldb.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://vuldb.com/vuln/432923","name":"https://vuldb.com/vuln/432923","refsource":"cna@vuldb.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://vuldb.com/cve/CVE-2026-124577","name":"https://vuldb.com/cve/CVE-2026-124577","refsource":"cna@vuldb.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://vuldb.com/vuln/432923/cti","name":"https://vuldb.com/vuln/432923/cti","refsource":"cna@vuldb.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-124577","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-124577","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Intelbras","product":"SG 2404 PoE L2+","version":"affected 1.00.70","platforms":[]},{"source":"CNA","vendor":"Intelbras","product":"SG 2404 PoE L2+","version":"affected 1.00.72","platforms":[]},{"source":"CNA","vendor":"Intelbras","product":"SG 2404 PoE L2+","version":"unaffected 1.00.74","platforms":[]}],"timeline":[{"source":"CNA","time":"2026-11-08T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"source":"CNA","time":"2026-11-08T01:00:00.000Z","lang":"en","value":"VulDB entry created"},{"source":"CNA","time":"2026-11-08T18:07:25.000Z","lang":"en","value":"VulDB entry last update"}],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"JoasHS (VulDB User)","lang":"en"},{"source":"CNA","value":"VulDB Vulnerability Moderation Team","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"124577","cve":"CVE-2026-124577","epss":"0.020670000","percentile":"0.815350000","score_date":"2026-11-09","updated_at":"2026-11-10 00:05:34"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"cpes":["cpe:2.3:h:intelbras:sg_2404_poe_l2_:*:*:*:*:*:*:*:*"],"modules":["Web Management Interface"],"product":"SG 2404 PoE L2+","vendor":"Intelbras","versions":[{"status":"affected","version":"1.00.70"},{"status":"affected","version":"1.00.72"},{"status":"unaffected","version":"1.00.74"}]}],"credits":[{"lang":"en","type":"reporter","value":"JoasHS (VulDB User)"},{"lang":"en","type":"coordinator","value":"VulDB Vulnerability Moderation Team"}],"descriptions":[{"lang":"en","value":"A weakness has been identified in Intelbras SG 2404 PoE L2+ 1.00.70/1.00.72. The affected element is an unknown function of the file /EXCU_SHELL of the component Web Management Interface. Executing a manipulation can lead to improper authentication. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 1.00.74 is sufficient to fix this issue. Upgrading the affected component is advised."}],"metrics":[{"cvssV4_0":{"baseScore":9.3,"baseSeverity":"CRITICAL","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"}},{"cvssV3_1":{"baseScore":9.8,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.1"}},{"cvssV3_0":{"baseScore":9.8,"baseSeverity":"CRITICAL","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","version":"3.0"}},{"cvssV2_0":{"baseScore":10,"vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:OF/RC:C","version":"2.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-287","description":"Improper Authentication","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-09T07:15:16.393Z","orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB"},"references":[{"name":"VDB-432923 | Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper authentication","tags":["vdb-entry"],"url":"https://vuldb.com/vuln/432923"},{"name":"VDB-432923 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"],"url":"https://vuldb.com/vuln/432923/cti"},{"name":"CVE-2026-124577 | CVE Analysis and Report","tags":["third-party-advisory"],"url":"https://vuldb.com/cve/CVE-2026-124577"},{"name":"Submit #1038184 | Intelbras SG 2404 PoE L2+ managed switch Firmware 1.00.70, 1.00.72 (hardware B1) Authentication bypass in web management interface allows unauthenticated execution of privileged CLI commands via /EXCU_SHELL","tags":["third-party-advisory"],"url":"https://vuldb.com/submit/1038184"}],"timeline":[{"lang":"en","time":"2026-11-08T00:00:00.000Z","value":"Advisory disclosed"},{"lang":"en","time":"2026-11-08T01:00:00.000Z","value":"VulDB entry created"},{"lang":"en","time":"2026-11-08T18:07:25.000Z","value":"VulDB entry last update"}],"title":"Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper authentication","x_generator":["VulDB PVTS v202611"]}},"cveMetadata":{"assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","assignerShortName":"VulDB","cveId":"CVE-2026-124577","datePublished":"2026-11-09T07:15:16.393Z","dateReserved":"2026-11-08T17:02:20.350Z","dateUpdated":"2026-11-09T07:15:16.393Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-09 08:17:02","lastModifiedDate":"2026-11-09 08:17:02","problem_types":["CWE-287","CWE-287 Improper Authentication"],"metrics":{"cvssMetricV40":[{"source":"cna@vuldb.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.9,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"PROOF_OF_CONCEPT","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"cna@vuldb.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"cna@vuldb.com","type":"Secondary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"124577","Ordinal":"1","Title":"Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper aut","CVE":"CVE-2026-124577","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"124577","Ordinal":"1","NoteData":"A weakness has been identified in Intelbras SG 2404 PoE L2+ 1.00.70/1.00.72. The affected element is an unknown function of the file /EXCU_SHELL of the component Web Management Interface. Executing a manipulation can lead to improper authentication. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 1.00.74 is sufficient to fix this issue. Upgrading the affected component is advised.","Type":"Description","Title":"Intelbras SG 2404 PoE L2+ Web Management EXCU_SHELL improper aut"}]}}}