{"api_version":"1","generated_at":"2026-11-18T18:43:37+00:00","cve":"CVE-2026-126978","urls":{"html":"https://cve.report/CVE-2026-126978","api":"https://cve.report/api/cve/CVE-2026-126978.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-126978","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-126978"},"summary":{"title":"Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability","description":"Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28434.","state":"PUBLISHED","assigner":"zdi","published_at":"2026-11-18 00:18:38","updated_at":"2026-11-18 18:19:04"},"problem_types":["CWE-122","CWE-122 CWE-122: Heap-based Buffer Overflow"],"metrics":[{"version":"3.0","source":"zdi-disclosures@trendmicro.com","type":"Secondary","score":"8.8","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.0","source":"CNA","type":"CVSS","score":"8.8","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"baseScore":8.8,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-963/","name":"https://www.zerodayinitiative.com/advisories/ZDI-26-963/","refsource":"zdi-disclosures@trendmicro.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-126978","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-126978","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Philips","product":"Hue Bridge","version":"affected 1.73.1973146020","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-126978","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-11-18T17:25:24.702818Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-11-18T17:26:09.225Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"Hue Bridge","vendor":"Philips","versions":[{"status":"affected","version":"1.73.1973146020"}]}],"dateAssigned":"2026-11-12T03:10:45.663Z","datePublic":"2026-11-13T20:16:00.088Z","descriptions":[{"lang":"en","value":"Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28434."}],"metrics":[{"cvssV3_0":{"baseScore":8.8,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"format":"CVSS"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-122","description":"CWE-122: Heap-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-17T23:16:16.044Z","orgId":"99f1926a-a320-47d8-bbb5-42feb611262e","shortName":"zdi"},"references":[{"name":"ZDI-26-963","tags":["x_research-advisory"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-963/"}],"source":{"lang":"en","value":"Sang Nguyen Thien (@gnas0x0018) and mistsu of Team ANHTUD"},"title":"Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability"}},"cveMetadata":{"assignerOrgId":"99f1926a-a320-47d8-bbb5-42feb611262e","assignerShortName":"zdi","cveId":"CVE-2026-126978","datePublished":"2026-11-17T23:16:16.044Z","dateReserved":"2026-11-12T03:10:45.637Z","dateUpdated":"2026-11-18T17:26:09.225Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-18 00:18:38","lastModifiedDate":"2026-11-18 18:19:04","problem_types":["CWE-122","CWE-122 CWE-122: Heap-based Buffer Overflow"],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-11-18T17:25:24.702818Z","id":"CVE-2026-126978","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"126978","Ordinal":"1","Title":"Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Over","CVE":"CVE-2026-126978","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"126978","Ordinal":"1","NoteData":"Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28434.","Type":"Description","Title":"Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Over"}]}}}