{"api_version":"1","generated_at":"2026-11-24T21:21:19+00:00","cve":"CVE-2026-127057","urls":{"html":"https://cve.report/CVE-2026-127057","api":"https://cve.report/api/cve/CVE-2026-127057.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-127057","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-127057"},"summary":{"title":"Exploitation of Weak or Known Passwords in Danfoss AK-SC 355 and AK-SM 800 Series","description":"The\nDanfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized\naccess when default credentials or known passwords are used for authentication.\nThese products were manufactured with default credentials documented in the\nproduct manual. All versions are affected.","state":"PUBLISHED","assigner":"Danfoss","published_at":"2026-11-20 11:18:30","updated_at":"2026-11-24 17:50:07"},"problem_types":["CWE-1392","CWE-1392 CWE-1392 Use of default credentials"],"metrics":[{"version":"4.0","source":"d7ff35af-cf88-454c-bab9-af60602f10f8","type":"Secondary","score":"9.9","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"9.9","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.9,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2026-12-02/","name":"https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2026-12-02/","refsource":"d7ff35af-cf88-454c-bab9-af60602f10f8","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-127057","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-127057","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Danfoss","product":"AK-SC 355","version":"affected latest custom","platforms":[]},{"source":"CNA","vendor":"Danfoss","product":"AK-SM 800","version":"affected latest custom","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"*  \n\nInstall according to the instructions of the manual, avoiding public IP exposure\n\n\n  *  \n\nUpdate the fleet (AK-SC355, AK-SM800) to current generation products (AK-SM800A series), to ensure receiving continuous cybersecurity updates.","time":"","lang":"en"}],"workarounds":[{"source":"CNA","title":"","value":"*  \n\nRemove\ninternet exposure of affected units and of all units exposed on public IP\n\n\n  *  \n\nRecommend\nusing strong and unique passwords\n\n\n  *  \n\nRe-establish\naccess to the units only through a secure VPN or in general over a protected\nnetwork","time":"","lang":"en"}],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"127057","cve":"CVE-2026-127057","epss":"0.006860000","percentile":"0.536050000","score_date":"2026-11-22","updated_at":"2026-11-23 00:03:20"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-127057","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-11-20T16:23:24.639923Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-11-20T16:39:10.395Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"affected","product":"AK-SC 355","vendor":"Danfoss","versions":[{"lessThanOrEqual":"latest","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"affected","product":"AK-SM 800","vendor":"Danfoss","versions":[{"lessThanOrEqual":"latest","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>The\nDanfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized\naccess when default credentials or known passwords are used for authentication.\nThese products were manufactured with default credentials documented in the\nproduct manual. All versions are affected.<strong> </strong></p>"}],"value":"The\nDanfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized\naccess when default credentials or known passwords are used for authentication.\nThese products were manufactured with default credentials documented in the\nproduct manual. All versions are affected."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.9,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1392","description":"CWE-1392 Use of default credentials","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-20T10:52:24.467Z","orgId":"d7ff35af-cf88-454c-bab9-af60602f10f8","shortName":"Danfoss"},"references":[{"url":"https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2026-12-02/"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<ul><li><p>Install according to the instructions of the manual, avoiding public IP exposure</p></li><li><p>Update the fleet (AK-SC355, AK-SM800) to current generation products (AK-SM800A series), to ensure receiving continuous cybersecurity updates.</p></li></ul>"}],"value":"*  \n\nInstall according to the instructions of the manual, avoiding public IP exposure\n\n\n  *  \n\nUpdate the fleet (AK-SC355, AK-SM800) to current generation products (AK-SM800A series), to ensure receiving continuous cybersecurity updates."}],"source":{"discovery":"UNKNOWN"},"title":"Exploitation of Weak or Known Passwords in Danfoss AK-SC 355 and AK-SM 800 Series","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p></p><ul><li><p>Remove\ninternet exposure of affected units and of all units exposed on public IP</p></li><li><p><span>Recommend\nusing strong and unique passwords</span></p></li><li><p><span>Re-establish\naccess to the units only through a secure VPN or in general over a protected\nnetwork</span></p></li></ul><p></p>"}],"value":"*  \n\nRemove\ninternet exposure of affected units and of all units exposed on public IP\n\n\n  *  \n\nRecommend\nusing strong and unique passwords\n\n\n  *  \n\nRe-establish\naccess to the units only through a secure VPN or in general over a protected\nnetwork"}],"x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"d7ff35af-cf88-454c-bab9-af60602f10f8","assignerShortName":"Danfoss","cveId":"CVE-2026-127057","datePublished":"2026-11-20T10:52:24.467Z","dateReserved":"2026-11-12T12:46:22.614Z","dateUpdated":"2026-11-20T16:39:10.395Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-20 11:18:30","lastModifiedDate":"2026-11-24 17:50:07","problem_types":["CWE-1392","CWE-1392 CWE-1392 Use of default credentials"],"metrics":{"cvssMetricV40":[{"source":"d7ff35af-cf88-454c-bab9-af60602f10f8","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-11-20T16:23:24.639923Z","id":"CVE-2026-127057","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"127057","Ordinal":"1","Title":"Exploitation of Weak or Known Passwords in Danfoss AK-SC 355 and","CVE":"CVE-2026-127057","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"127057","Ordinal":"1","NoteData":"The\nDanfoss legacy AK-SC 355 and AK-SM 800 Series are vulnerable to unauthorized\naccess when default credentials or known passwords are used for authentication.\nThese products were manufactured with default credentials documented in the\nproduct manual. All versions are affected.","Type":"Description","Title":"Exploitation of Weak or Known Passwords in Danfoss AK-SC 355 and"}]}}}