{"api_version":"1","generated_at":"2026-11-19T20:42:36+00:00","cve":"CVE-2026-131233","urls":{"html":"https://cve.report/CVE-2026-131233","api":"https://cve.report/api/cve/CVE-2026-131233.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-131233","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-131233"},"summary":{"title":"SPL Injection through Time Center Dashboard Drilldowns in Splunk Enterprise Security","description":"In Splunk Enterprise Security versions below 8.7.0, a user that holds a role with the run_collect capability could store attacker-controlled values in endpoint summary data. If another user who can access the Time Center dashboard selects an affected row, Splunk Enterprise Security could run attacker-controlled Search Processing Language (SPL) commands using the permissions of the user who selects the row. The user who stores the values could then access sensitive data and modify some data available to the user who selects the row.\nThe vulnerability is possible because the Time Center dashboard does not safely escape endpoint summary values before inserting them into drilldown searches.\nFor more information see Define roles on the Splunk platform with capabilities (https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/manage-splunk-platform-users-and-roles/define-roles-on-the-splunk-platform-with-capabilities) and Endpoint dashboards (https://help.splunk.com/en/splunk-enterprise-security-8/user-guide/8.7/analytics/endpoint-dashboards) in the Splunk documentation.","state":"PUBLISHED","assigner":"cisco","published_at":"2026-11-19 20:17:37","updated_at":"2026-11-19 20:17:37"},"problem_types":["CWE-116","CWE-116 The software prepares a structured message for communication with another component, but encoding or escaping of the data is either missing or done incorrectly. As a result, the intended structure of the message is not preserved."],"metrics":[{"version":"3.1","source":"psirt@cisco.com","type":"Primary","score":"5.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"5.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N","data":{"baseScore":5.4,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N","version":"3.1"}}],"references":[{"url":"https://advisory.splunk.com/advisories/SVD-2026-1106","name":"https://advisory.splunk.com/advisories/SVD-2026-1106","refsource":"psirt@cisco.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-131233","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-131233","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Splunk","product":"Splunk Enterprise Security","version":"affected 8.7.0 custom","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Upgrade Splunk Enterprise Security and Splunk App for PCI Compliance to version 8.7.0 or higher.","time":"","lang":"en"}],"workarounds":[{"source":"CNA","title":"","value":"The vulnerability affects instances with Splunk Web turned on. Turning Splunk Web off is a possible workaround.\nSee [Disable unnecessary Splunk Enterprise components](https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/install-splunk-enterprise-securely/disable-unnecessary-splunk-enterprise-components) and the [web.conf](https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/configuration-file-reference/10.4.0-configuration-file-reference/web.conf) configuration specification file for more information on turning off Splunk Web.","time":"","lang":"en"}],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"product":"Splunk Enterprise Security","vendor":"Splunk","versions":[{"lessThan":"8.7.0","status":"affected","version":"0","versionType":"custom"}]}],"datePublic":"2026-11-18T00:00:00.000Z","descriptions":[{"lang":"en","value":"In Splunk Enterprise Security versions below 8.7.0, a user that holds a role with the run_collect capability could store attacker-controlled values in endpoint summary data. If another user who can access the Time Center dashboard selects an affected row, Splunk Enterprise Security could run attacker-controlled Search Processing Language (SPL) commands using the permissions of the user who selects the row. The user who stores the values could then access sensitive data and modify some data available to the user who selects the row.\nThe vulnerability is possible because the Time Center dashboard does not safely escape endpoint summary values before inserting them into drilldown searches.\nFor more information see Define roles on the Splunk platform with capabilities (https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/manage-splunk-platform-users-and-roles/define-roles-on-the-splunk-platform-with-capabilities) and Endpoint dashboards (https://help.splunk.com/en/splunk-enterprise-security-8/user-guide/8.7/analytics/endpoint-dashboards) in the Splunk documentation."}],"metrics":[{"cvssV3_1":{"baseScore":5.4,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-116","description":"The software prepares a structured message for communication with another component, but encoding or escaping of the data is either missing or done incorrectly. As a result, the intended structure of the message is not preserved.","lang":"en","type":"cwe"}]}],"providerMetadata":{"dateUpdated":"2026-11-19T19:56:04.995Z","orgId":"d1c1063e-7a18-46af-9102-31f8928bc633","shortName":"cisco"},"references":[{"url":"https://advisory.splunk.com/advisories/SVD-2026-1106"}],"solutions":[{"lang":"en","value":"Upgrade Splunk Enterprise Security and Splunk App for PCI Compliance to version 8.7.0 or higher."}],"source":{"advisory":"SVD-2026-1106","discovery":""},"title":"SPL Injection through Time Center Dashboard Drilldowns in Splunk Enterprise Security","workarounds":[{"lang":"en","value":"The vulnerability affects instances with Splunk Web turned on. Turning Splunk Web off is a possible workaround.\nSee [Disable unnecessary Splunk Enterprise components](https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/install-splunk-enterprise-securely/disable-unnecessary-splunk-enterprise-components) and the [web.conf](https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/configuration-file-reference/10.4.0-configuration-file-reference/web.conf) configuration specification file for more information on turning off Splunk Web."}]}},"cveMetadata":{"assignerOrgId":"d1c1063e-7a18-46af-9102-31f8928bc633","assignerShortName":"cisco","cveId":"CVE-2026-131233","datePublished":"2026-11-19T19:56:04.995Z","dateReserved":"2026-11-17T20:26:14.305Z","dateUpdated":"2026-11-19T19:56:04.995Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-19 20:17:37","lastModifiedDate":"2026-11-19 20:17:37","problem_types":["CWE-116","CWE-116 The software prepares a structured message for communication with another component, but encoding or escaping of the data is either missing or done incorrectly. As a result, the intended structure of the message is not preserved."],"metrics":{"cvssMetricV31":[{"source":"psirt@cisco.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.2,"impactScore":4.2}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"131233","Ordinal":"1","Title":"SPL Injection through Time Center Dashboard Drilldowns in Splunk","CVE":"CVE-2026-131233","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"131233","Ordinal":"1","NoteData":"In Splunk Enterprise Security versions below 8.7.0, a user that holds a role with the run_collect capability could store attacker-controlled values in endpoint summary data. If another user who can access the Time Center dashboard selects an affected row, Splunk Enterprise Security could run attacker-controlled Search Processing Language (SPL) commands using the permissions of the user who selects the row. The user who stores the values could then access sensitive data and modify some data available to the user who selects the row.\nThe vulnerability is possible because the Time Center dashboard does not safely escape endpoint summary values before inserting them into drilldown searches.\nFor more information see Define roles on the Splunk platform with capabilities (https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/manage-splunk-platform-users-and-roles/define-roles-on-the-splunk-platform-with-capabilities) and Endpoint dashboards (https://help.splunk.com/en/splunk-enterprise-security-8/user-guide/8.7/analytics/endpoint-dashboards) in the Splunk documentation.","Type":"Description","Title":"SPL Injection through Time Center Dashboard Drilldowns in Splunk"}]}}}