{"api_version":"1","generated_at":"2026-11-20T11:36:51+00:00","cve":"CVE-2026-131812","urls":{"html":"https://cve.report/CVE-2026-131812","api":"https://cve.report/api/cve/CVE-2026-131812.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-131812","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-131812"},"summary":{"title":"United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability","description":"United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the parsing of FTP URL paths during firmware updates. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28960.","state":"PUBLISHED","assigner":"zdi","published_at":"2026-11-19 16:20:09","updated_at":"2026-11-19 17:18:02"},"problem_types":["CWE-121","CWE-121 CWE-121: Stack-based Buffer Overflow"],"metrics":[{"version":"3.0","source":"zdi-disclosures@trendmicro.com","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.0","source":"CNA","type":"CVSS","score":"7.5","severity":"HIGH","vector":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-1034/","name":"https://www.zerodayinitiative.com/advisories/ZDI-26-1034/","refsource":"zdi-disclosures@trendmicro.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-131812","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-131812","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"United Chargers","product":"Grizzl-E Smart 40A","version":"affected GWM-07.029-03","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-131812","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-11-19T16:33:59.218747Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-11-19T16:47:02.950Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unknown","product":"Grizzl-E Smart 40A","vendor":"United Chargers","versions":[{"status":"affected","version":"GWM-07.029-03"}]}],"dateAssigned":"2026-11-17T22:56:03.583Z","datePublic":"2026-11-18T20:03:26.707Z","descriptions":[{"lang":"en","value":"United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the parsing of FTP URL paths during firmware updates. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28960."}],"metrics":[{"cvssV3_0":{"baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"format":"CVSS"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","description":"CWE-121: Stack-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-19T16:08:23.127Z","orgId":"99f1926a-a320-47d8-bbb5-42feb611262e","shortName":"zdi"},"references":[{"name":"ZDI-26-1034","tags":["x_research-advisory"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-1034/"}],"source":{"lang":"en","value":"Hyeongseok Lee (@fluorite_pwn), Yunje Shin (@YunjeShin), Chaeeul Hyun (@yskm_Gunter), Ingyu Yang (@Mafty5275), Hoseok Kang (@clay419), Seungyeon Park (@vvsy46), and Wonjun Choi (@won6_choi) of BoB::Takedown"},"title":"United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"}},"cveMetadata":{"assignerOrgId":"99f1926a-a320-47d8-bbb5-42feb611262e","assignerShortName":"zdi","cveId":"CVE-2026-131812","datePublished":"2026-11-19T16:08:23.127Z","dateReserved":"2026-11-17T22:56:03.551Z","dateUpdated":"2026-11-19T16:47:02.950Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-19 16:20:09","lastModifiedDate":"2026-11-19 17:18:02","problem_types":["CWE-121","CWE-121 CWE-121: Stack-based Buffer Overflow"],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.6,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-11-19T16:33:59.218747Z","id":"CVE-2026-131812","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"131812","Ordinal":"1","Title":"United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-ba","CVE":"CVE-2026-131812","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"131812","Ordinal":"1","NoteData":"United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the parsing of FTP URL paths during firmware updates. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-28960.","Type":"Description","Title":"United Chargers Grizzl-E Smart 40A FTP URL Path Parsing Stack-ba"}]}}}