{"api_version":"1","generated_at":"2026-11-20T20:43:06+00:00","cve":"CVE-2026-134047","urls":{"html":"https://cve.report/CVE-2026-134047","api":"https://cve.report/api/cve/CVE-2026-134047.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-134047","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-134047"},"summary":{"title":"Open Robotics RViz IntensityPCTransformer PointField Out-Of-Bounds Read Denial-of-Service Vulnerability","description":"Open Robotics RViz IntensityPCTransformer PointField Out-Of-Bounds Read Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Open Robotics RViz. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the IntensityPCTransformer handling of PointCloud2 messages. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-32645.","state":"PUBLISHED","assigner":"zdi","published_at":"2026-11-20 20:17:39","updated_at":"2026-11-20 20:17:39"},"problem_types":["CWE-125","CWE-125 CWE-125: Out-of-bounds Read"],"metrics":[{"version":"3.0","source":"zdi-disclosures@trendmicro.com","type":"Secondary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.0","source":"CNA","type":"CVSS","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"baseScore":6.5,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"}}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-1022/","name":"https://www.zerodayinitiative.com/advisories/ZDI-26-1022/","refsource":"zdi-disclosures@trendmicro.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-134047","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-134047","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Open Robotics","product":"RViz","version":"affected 16.0.1","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unknown","product":"RViz","vendor":"Open Robotics","versions":[{"status":"affected","version":"16.0.1"}]}],"dateAssigned":"2026-11-20T19:43:59.189Z","datePublic":"2026-11-18T15:38:03.768Z","descriptions":[{"lang":"en","value":"Open Robotics RViz IntensityPCTransformer PointField Out-Of-Bounds Read Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Open Robotics RViz. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the IntensityPCTransformer handling of PointCloud2 messages. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-32645."}],"metrics":[{"cvssV3_0":{"baseScore":6.5,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"format":"CVSS"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","description":"CWE-125: Out-of-bounds Read","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-20T19:47:17.080Z","orgId":"99f1926a-a320-47d8-bbb5-42feb611262e","shortName":"zdi"},"references":[{"name":"ZDI-26-1022","tags":["x_research-advisory"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-1022/"}],"source":{"lang":"en","value":"Mat Powell of TrendAI Zero Day Initiative"},"title":"Open Robotics RViz IntensityPCTransformer PointField Out-Of-Bounds Read Denial-of-Service Vulnerability"}},"cveMetadata":{"assignerOrgId":"99f1926a-a320-47d8-bbb5-42feb611262e","assignerShortName":"zdi","cveId":"CVE-2026-134047","datePublished":"2026-11-20T19:47:17.080Z","dateReserved":"2026-11-20T19:43:59.151Z","dateUpdated":"2026-11-20T19:47:17.080Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-20 20:17:39","lastModifiedDate":"2026-11-20 20:17:39","problem_types":["CWE-125","CWE-125 CWE-125: Out-of-bounds Read"],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"134047","Ordinal":"1","Title":"Open Robotics RViz IntensityPCTransformer PointField Out-Of-Boun","CVE":"CVE-2026-134047","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"134047","Ordinal":"1","NoteData":"Open Robotics RViz IntensityPCTransformer PointField Out-Of-Bounds Read Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Open Robotics RViz. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the IntensityPCTransformer handling of PointCloud2 messages. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-32645.","Type":"Description","Title":"Open Robotics RViz IntensityPCTransformer PointField Out-Of-Boun"}]}}}