{"api_version":"1","generated_at":"2026-11-27T16:38:52+00:00","cve":"CVE-2026-135278","urls":{"html":"https://cve.report/CVE-2026-135278","api":"https://cve.report/api/cve/CVE-2026-135278.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-135278","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-135278"},"summary":{"title":"CVE-2026-135278","description":"A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.24.29), Mendix Runtime V11 (All versions < V11.17.0), Mendix Runtime V11.12 (All versions < V11.12.8), Mendix Runtime V11.6 (All versions < V11.6.13), Mendix Runtime V9 (All versions < V9.24.45). Affected versions of Mendix Runtime do not end existing sessions when a user account is set to inactive. The account state is checked at sign-in, but not on later requests made with a session that already exists. A user who is deactivated while signed in can keep using that session for as long as the client keeps it alive.\r\n\r\nThis could allow an authenticated remote attacker to read and change data within previous permissions for a persistent session.","state":"PUBLISHED","assigner":"siemens","published_at":"2026-11-27 14:17:03","updated_at":"2026-11-27 14:17:03"},"problem_types":["CWE-613","CWE-613 CWE-613: Insufficient Session Expiration"],"metrics":[{"version":"4.0","source":"productcert@siemens.com","type":"Secondary","score":"5.3","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"DECLARED","score":"5.3","severity":"MEDIUM","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N","data":{"baseScore":5.3,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"}},{"version":"3.1","source":"productcert@siemens.com","type":"Primary","score":"5.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"DECLARED","score":"5.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","data":{"baseScore":5.4,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","version":"3.1"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-579716.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-579716.html","refsource":"productcert@siemens.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-135278","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-135278","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Siemens","product":"Mendix Runtime V10","version":"affected V10.24.29 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Mendix Runtime V11","version":"affected V11.17.0 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Mendix Runtime V11.12","version":"affected V11.12.8 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Mendix Runtime V11.6","version":"affected V11.6.13 custom","platforms":[]},{"source":"CNA","vendor":"Siemens","product":"Mendix Runtime V9","version":"affected V9.24.45 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unknown","product":"Mendix Runtime V10","vendor":"Siemens","versions":[{"lessThan":"V10.24.29","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Mendix Runtime V11","vendor":"Siemens","versions":[{"lessThan":"V11.17.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Mendix Runtime V11.12","vendor":"Siemens","versions":[{"lessThan":"V11.12.8","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Mendix Runtime V11.6","vendor":"Siemens","versions":[{"lessThan":"V11.6.13","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"Mendix Runtime V9","vendor":"Siemens","versions":[{"lessThan":"V9.24.45","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.24.29), Mendix Runtime V11 (All versions < V11.17.0), Mendix Runtime V11.12 (All versions < V11.12.8), Mendix Runtime V11.6 (All versions < V11.6.13), Mendix Runtime V9 (All versions < V9.24.45). Affected versions of Mendix Runtime do not end existing sessions when a user account is set to inactive. The account state is checked at sign-in, but not on later requests made with a session that already exists. A user who is deactivated while signed in can keep using that session for as long as the client keeps it alive.\r\n\r\nThis could allow an authenticated remote attacker to read and change data within previous permissions for a persistent session."}],"metrics":[{"cvssV3_1":{"baseScore":5.4,"baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","version":"3.1"}},{"cvssV4_0":{"baseScore":5.3,"baseSeverity":"MEDIUM","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-613","description":"CWE-613: Insufficient Session Expiration","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-11-27T13:21:54.085Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-579716.html"}]}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2026-135278","datePublished":"2026-11-27T13:21:54.085Z","dateReserved":"2026-11-23T16:08:11.807Z","dateUpdated":"2026-11-27T13:21:54.085Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-11-27 14:17:03","lastModifiedDate":"2026-11-27 14:17:03","problem_types":["CWE-613","CWE-613 CWE-613: Insufficient Session Expiration"],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.5}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"135278","Ordinal":"1","Title":"CVE-2026-135278","CVE":"CVE-2026-135278","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"135278","Ordinal":"1","NoteData":"A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.24.29), Mendix Runtime V11 (All versions < V11.17.0), Mendix Runtime V11.12 (All versions < V11.12.8), Mendix Runtime V11.6 (All versions < V11.6.13), Mendix Runtime V9 (All versions < V9.24.45). Affected versions of Mendix Runtime do not end existing sessions when a user account is set to inactive. The account state is checked at sign-in, but not on later requests made with a session that already exists. A user who is deactivated while signed in can keep using that session for as long as the client keeps it alive.\r\n\r\nThis could allow an authenticated remote attacker to read and change data within previous permissions for a persistent session.","Type":"Description","Title":"CVE-2026-135278"}]}}}