{"api_version":"1","generated_at":"2026-09-17T14:13:40+00:00","cve":"CVE-2026-15688","urls":{"html":"https://cve.report/CVE-2026-15688","api":"https://cve.report/api/cve/CVE-2026-15688.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-15688","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-15688"},"summary":{"title":"Password Authentication Bypass Vulnerability in GX Works3 and Motion Control Setting","description":"Incorrect Implementation of Authentication Algorithm Vulnerability in Mitsubishi Electric GX Works3 and Motion Control Setting allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modifying part of the executable module in memory, and thereby may be able to view, tamper with, destroy, or delete control programs.","state":"PUBLISHED","assigner":"Mitsubishi","published_at":"2026-09-17 09:16:39","updated_at":"2026-09-17 13:16:42"},"problem_types":["CWE-303","CWE-303 CWE-303 Incorrect Implementation of Authentication Algorithm"],"metrics":[{"version":"4.0","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","score":"9.2","severity":"CRITICAL","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.2,"baseSeverity":"CRITICAL","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"9.2","severity":"CRITICAL","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":9.2,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://jvn.jp/vu/JVNVU99700314","name":"https://jvn.jp/vu/JVNVU99700314","refsource":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf","name":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf","refsource":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-15688","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-15688","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"GX Works3","version":"affected All versions","platforms":[]},{"source":"CNA","vendor":"Mitsubishi Electric Corporation","product":"Motion Control Setting","version":"affected All versions","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-15688","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-09-17T12:24:48.176339Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-09-17T12:25:10.782Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"GX Works3","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"All versions"}]},{"defaultStatus":"unaffected","product":"Motion Control Setting","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"All versions"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Incorrect Implementation of Authentication Algorithm Vulnerability in Mitsubishi Electric GX Works3 and Motion Control Setting allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modifying part of the executable module in memory, and thereby may be able to view, tamper with, destroy, or delete control programs."}],"value":"Incorrect Implementation of Authentication Algorithm Vulnerability in Mitsubishi Electric GX Works3 and Motion Control Setting allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modifying part of the executable module in memory, and thereby may be able to view, tamper with, destroy, or delete control programs."}],"impacts":[{"descriptions":[{"lang":"en","value":"Password Authentication Bypass"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":9.2,"baseSeverity":"CRITICAL","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-303","description":"CWE-303 Incorrect Implementation of Authentication Algorithm","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-17T08:15:27.769Z","orgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","shortName":"Mitsubishi"},"references":[{"tags":["vendor-advisory"],"url":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf"},{"tags":["government-resource"],"url":"https://jvn.jp/vu/JVNVU99700314"}],"source":{"discovery":"UNKNOWN"},"title":"Password Authentication Bypass Vulnerability in GX Works3 and Motion Control Setting","x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","assignerShortName":"Mitsubishi","cveId":"CVE-2026-15688","datePublished":"2026-09-17T08:15:27.769Z","dateReserved":"2026-07-14T00:29:02.381Z","dateUpdated":"2026-09-17T12:25:10.782Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-17 09:16:39","lastModifiedDate":"2026-09-17 13:16:42","problem_types":["CWE-303","CWE-303 CWE-303 Incorrect Implementation of Authentication Algorithm"],"metrics":{"cvssMetricV40":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.2,"baseSeverity":"CRITICAL","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-17T12:24:48.176339Z","id":"CVE-2026-15688","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"15688","Ordinal":"1","Title":"Password Authentication Bypass Vulnerability in GX Works3 and Mo","CVE":"CVE-2026-15688","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"15688","Ordinal":"1","NoteData":"Incorrect Implementation of Authentication Algorithm Vulnerability in Mitsubishi Electric GX Works3 and Motion Control Setting allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modifying part of the executable module in memory, and thereby may be able to view, tamper with, destroy, or delete control programs.","Type":"Description","Title":"Password Authentication Bypass Vulnerability in GX Works3 and Mo"}]}}}