{"api_version":"1","generated_at":"2026-08-22T06:11:58+00:00","cve":"CVE-2026-15961","urls":{"html":"https://cve.report/CVE-2026-15961","api":"https://cve.report/api/cve/CVE-2026-15961.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-15961","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-15961"},"summary":{"title":"Power System Information Disclosure","description":"IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 IBM PowerVM could allow a local attacker to obtain sensitive information or cause a denial of service due to improper control of format strings.","state":"PUBLISHED","assigner":"ibm","published_at":"2026-08-19 15:16:56","updated_at":"2026-08-20 16:17:08"},"problem_types":["CWE-134","CWE-134 CWE-134 Use of Externally-Controlled Format String"],"metrics":[{"version":"3.1","source":"psirt@us.ibm.com","type":"Secondary","score":"5.2","severity":"MEDIUM","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:H","baseScore":5.2,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"5.2","severity":"MEDIUM","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:H","data":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5.2,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:H","version":"3.1"}}],"references":[{"url":"https://www.ibm.com/support/pages/node/7283228","name":"https://www.ibm.com/support/pages/node/7283228","refsource":"psirt@us.ibm.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-15961","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-15961","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"IBM","product":"PowerVM Hypervisor","version":"affected FW1120.00","platforms":[]},{"source":"CNA","vendor":"IBM","product":"PowerVM Hypervisor","version":"affected FW1110.00 FW1110.30 semver","platforms":[]},{"source":"CNA","vendor":"IBM","product":"PowerVM Hypervisor","version":"affected FW1060.00 FW1060.80 semver","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System S1122 (9824-22A)\n  *  IBM Power System S1124 (9824-42A)\n  *  IBM Power System S1122s (9824-22B)\n  *  IBM Power System S1114 (9824-41B)\n  *  IBM Power System L1122 (9856-22H)\n  *  IBM Power System L1124 (9856-42H)\n  *  IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n  *  IBM Power System S1112 (9242-21B, 9242-21T)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System E1080 (9080-HEX)\n\n\nCustomers with the products below should install  FW1060.81(1060_191), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System S1022 (9105-22A)\n  *  IBM Power System S1024 (9105-42A)\n  *  IBM Power System S1022s (9105-22B)\n  *  IBM Power System S1014 (9105-41B)\n  *  IBM Power System L1022 (9786-22H)\n  *  IBM Power System L1024 (9786-42H)\n  *  IBM Power System E1050 (9043-MRX)\n  *  IBM Power System S1012 (9028-21B)\n\n\n\n\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"15961","cve":"CVE-2026-15961","epss":"0.000950000","percentile":"0.007230000","score_date":"2026-08-21","updated_at":"2026-08-22 00:12:49"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-15961","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-08-20T14:19:20.884588Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-08-20T15:22:20.226Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"cpes":["cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*"],"product":"PowerVM Hypervisor","vendor":"IBM","versions":[{"status":"affected","version":"FW1120.00"},{"lessThanOrEqual":"FW1110.30","status":"affected","version":"FW1110.00","versionType":"semver"},{"lessThanOrEqual":"FW1060.80","status":"affected","version":"FW1060.00","versionType":"semver"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 IBM PowerVM could allow a local attacker to obtain sensitive information or cause a denial of service due to improper control of format strings.</p>"}],"value":"IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 IBM PowerVM could allow a local attacker to obtain sensitive information or cause a denial of service due to improper control of format strings."}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5.2,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-134","description":"CWE-134 Use of Externally-Controlled Format String","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-19T20:06:30.940Z","orgId":"9a959283-ebb5-44b6-b705-dcc2bbced522","shortName":"ibm"},"references":[{"tags":["vendor-advisory","patch"],"url":"https://www.ibm.com/support/pages/node/7283228"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.<br/>Power 11</p><ol><li>IBM Power System E1180 (9080-HEU)</li></ol><p>Customers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.<br/>Power 11</p><ol><li>IBM Power System S1122 (9824-22A)</li><li>IBM Power System S1124 (9824-42A)</li><li>IBM Power System S1122s (9824-22B)</li><li>IBM Power System S1114 (9824-41B)</li><li>IBM Power System L1122 (9856-22H)</li><li>IBM Power System L1124 (9856-42H)</li><li>IBM Power System E1150 (9043-MRU)</li></ol><p>Customers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.</p><p>Power 11</p><ol><li>IBM Power System S1112 (9242-21B, 9242-21T)</li></ol><p><br/>Customers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.<br/>Power 10</p><ol><li>IBM Power System E1080 (9080-HEX)</li></ol><p>Customers with the products below should install  FW1060.81(1060_191), or newer to remediate this vulnerability.<br/>Power 10</p><ol><li>IBM Power System S1022 (9105-22A)</li><li>IBM Power System S1024 (9105-42A)</li><li>IBM Power System S1022s (9105-22B)</li><li>IBM Power System S1014 (9105-41B)</li><li>IBM Power System L1022 (9786-22H)</li><li>IBM Power System L1024 (9786-42H)</li><li>IBM Power System E1050 (9043-MRX)</li><li>IBM Power System S1012 (9028-21B)</li></ol><p></p><p><em>The images mentioned above can be located at IBM Fix Central : </em><a href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"><em>https://www.ibm.com/support/fixcentral/</em></a></p>"}],"value":"Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n  *  IBM Power System S1122 (9824-22A)\n  *  IBM Power System S1124 (9824-42A)\n  *  IBM Power System S1122s (9824-22B)\n  *  IBM Power System S1114 (9824-41B)\n  *  IBM Power System L1122 (9856-22H)\n  *  IBM Power System L1124 (9856-42H)\n  *  IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n  *  IBM Power System S1112 (9242-21B, 9242-21T)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System E1080 (9080-HEX)\n\n\nCustomers with the products below should install  FW1060.81(1060_191), or newer to remediate this vulnerability.\nPower 10\n\n  *  IBM Power System S1022 (9105-22A)\n  *  IBM Power System S1024 (9105-42A)\n  *  IBM Power System S1022s (9105-22B)\n  *  IBM Power System S1014 (9105-41B)\n  *  IBM Power System L1022 (9786-22H)\n  *  IBM Power System L1024 (9786-42H)\n  *  IBM Power System E1050 (9043-MRX)\n  *  IBM Power System S1012 (9028-21B)\n\n\n\n\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/"}],"title":"Power System Information Disclosure"}},"cveMetadata":{"assignerOrgId":"9a959283-ebb5-44b6-b705-dcc2bbced522","assignerShortName":"ibm","cveId":"CVE-2026-15961","datePublished":"2026-08-19T14:36:03.055Z","dateReserved":"2026-07-16T14:14:20.484Z","dateUpdated":"2026-08-20T15:22:20.226Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-19 15:16:56","lastModifiedDate":"2026-08-20 16:17:08","problem_types":["CWE-134","CWE-134 CWE-134 Use of Externally-Controlled Format String"],"metrics":{"cvssMetricV31":[{"source":"psirt@us.ibm.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:H","baseScore":5.2,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"HIGH"},"exploitabilityScore":0.5,"impactScore":4.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-20T14:19:20.884588Z","id":"CVE-2026-15961","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"15961","Ordinal":"1","Title":"Power System Information Disclosure","CVE":"CVE-2026-15961","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"15961","Ordinal":"1","NoteData":"IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 IBM PowerVM could allow a local attacker to obtain sensitive information or cause a denial of service due to improper control of format strings.","Type":"Description","Title":"Power System Information Disclosure"}]}}}