{"api_version":"1","generated_at":"2026-08-24T14:59:01+00:00","cve":"CVE-2026-16323","urls":{"html":"https://cve.report/CVE-2026-16323","api":"https://cve.report/api/cve/CVE-2026-16323.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-16323","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-16323"},"summary":{"title":"Authentication Bypass via Execution After Redirect in FuyaSoft's Architect Panel Web Management Panel","description":"Execution after redirect (EAR) vulnerability in FuyaWeb Internet and Informatics Services ArchitectPanel Web Admin Panel allows Authentication Bypass.\n\nThis issue affects ArchitectPanel Web Admin Panel: through 28072026.","state":"PUBLISHED","assigner":"TR-CERT","published_at":"2026-08-21 08:16:42","updated_at":"2026-08-21 21:16:54"},"problem_types":["CWE-698","CWE-698 CWE-698 Execution after redirect (EAR)"],"metrics":[{"version":"3.1","source":"iletisim@usom.gov.tr","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}}],"references":[{"url":"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-26-0882","name":"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-26-0882","refsource":"iletisim@usom.gov.tr","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-16323","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-16323","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"FuyaWeb Internet and Informatics Services","product":"ArchitectPanel Web Admin Panel","version":"affected 28072026 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Basri Akkaya","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"16323","cve":"CVE-2026-16323","epss":"0.003730000","percentile":"0.305860000","score_date":"2026-08-23","updated_at":"2026-08-24 00:11:16"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-16323","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-08-21T19:46:03.728102Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-08-21T20:08:37.537Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"ArchitectPanel Web Admin Panel","vendor":"FuyaWeb Internet and Informatics Services","versions":[{"lessThanOrEqual":"28072026","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Basri Akkaya"}],"datePublic":"2026-08-21T07:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Execution after redirect (EAR) vulnerability in FuyaWeb Internet and Informatics Services ArchitectPanel Web Admin Panel allows Authentication Bypass.<p>This issue affects ArchitectPanel Web Admin Panel: through 28072026.</p>"}],"value":"Execution after redirect (EAR) vulnerability in FuyaWeb Internet and Informatics Services ArchitectPanel Web Admin Panel allows Authentication Bypass.\n\nThis issue affects ArchitectPanel Web Admin Panel: through 28072026."}],"impacts":[{"capecId":"CAPEC-115","descriptions":[{"lang":"en","value":"CAPEC-115 Authentication Bypass"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-698","description":"CWE-698 Execution after redirect (EAR)","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-21T07:20:33.800Z","orgId":"ca940d4e-fea4-4aa2-9a58-591a58b1ce21","shortName":"TR-CERT"},"references":[{"tags":["government-resource"],"url":"https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-26-0882"}],"source":{"advisory":"TR-26-0882","defect":["TR-26-0882"],"discovery":"UNKNOWN"},"title":"Authentication Bypass via Execution After Redirect in FuyaSoft's Architect Panel Web Management Panel","x_generator":{"engine":"Vulnogram 1.0.4"}}},"cveMetadata":{"assignerOrgId":"ca940d4e-fea4-4aa2-9a58-591a58b1ce21","assignerShortName":"TR-CERT","cveId":"CVE-2026-16323","datePublished":"2026-08-21T07:20:33.800Z","dateReserved":"2026-07-20T17:41:28.040Z","dateUpdated":"2026-08-21T20:08:37.537Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-21 08:16:42","lastModifiedDate":"2026-08-21 21:16:54","problem_types":["CWE-698","CWE-698 CWE-698 Execution after redirect (EAR)"],"metrics":{"cvssMetricV31":[{"source":"iletisim@usom.gov.tr","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-21T19:46:03.728102Z","id":"CVE-2026-16323","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"16323","Ordinal":"1","Title":"Authentication Bypass via Execution After Redirect in FuyaSoft's","CVE":"CVE-2026-16323","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"16323","Ordinal":"1","NoteData":"Execution after redirect (EAR) vulnerability in FuyaWeb Internet and Informatics Services ArchitectPanel Web Admin Panel allows Authentication Bypass.\n\nThis issue affects ArchitectPanel Web Admin Panel: through 28072026.","Type":"Description","Title":"Authentication Bypass via Execution After Redirect in FuyaSoft's"}]}}}