{"api_version":"1","generated_at":"2026-09-13T13:44:40+00:00","cve":"CVE-2026-16675","urls":{"html":"https://cve.report/CVE-2026-16675","api":"https://cve.report/api/cve/CVE-2026-16675.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-16675","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-16675"},"summary":{"title":"Rockwell Automation FactoryTalk® Activation Manager - Privilege Escalation","description":"A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.","state":"PUBLISHED","assigner":"Rockwell","published_at":"2026-09-01 14:17:25","updated_at":"2026-09-01 20:50:01"},"problem_types":["CWE-307","CWE-307 CWE-307 Improper restriction of excessive authentication attempts"],"metrics":[{"version":"4.0","source":"PSIRT@rockwellautomation.com","type":"Secondary","score":"8.5","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"8.5","severity":"HIGH","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1799.html","name":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1799.html","refsource":"PSIRT@rockwellautomation.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-16675","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-16675","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Rockwell Automation","product":"FactoryTalk® Activation Manager","version":"affected Version 5.02 and below","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Upgrade to version 5.03 or later.","time":"","lang":"en"}],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"16675","cve":"CVE-2026-16675","epss":"0.001050000","percentile":"0.011490000","score_date":"2026-09-03","updated_at":"2026-09-04 00:08:06"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-16675","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-09-01T15:42:10.542923Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-09-01T15:42:20.636Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"FactoryTalk® Activation Manager","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"Version 5.02 and below"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:rockwell_automation:factorytalk_activation_manager:version_5.02_and_below:*:*:*:*:*:*:*","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources."}],"value":"A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-307","description":"CWE-307 Improper restriction of excessive authentication attempts","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-01T13:18:58.120Z","orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1799.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Upgrade to version&nbsp;5.03 or later."}],"value":"Upgrade to version 5.03 or later."}],"source":{"advisory":"SD1799","discovery":"EXTERNAL"},"title":"Rockwell Automation FactoryTalk® Activation Manager - Privilege Escalation","x_generator":{"engine":"Vulnogram 1.0.5"}}},"cveMetadata":{"assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","assignerShortName":"Rockwell","cveId":"CVE-2026-16675","datePublished":"2026-09-01T13:18:58.120Z","dateReserved":"2026-07-22T20:04:45.545Z","dateUpdated":"2026-09-01T15:42:20.636Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-01 14:17:25","lastModifiedDate":"2026-09-01 20:50:01","problem_types":["CWE-307","CWE-307 CWE-307 Improper restriction of excessive authentication attempts"],"metrics":{"cvssMetricV40":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-01T15:42:10.542923Z","id":"CVE-2026-16675","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"16675","Ordinal":"1","Title":"Rockwell Automation FactoryTalk® Activation Manager - Privilege ","CVE":"CVE-2026-16675","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"16675","Ordinal":"1","NoteData":"A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.","Type":"Description","Title":"Rockwell Automation FactoryTalk® Activation Manager - Privilege "}]}}}