{"api_version":"1","generated_at":"2026-08-22T08:46:02+00:00","cve":"CVE-2026-16828","urls":{"html":"https://cve.report/CVE-2026-16828","api":"https://cve.report/api/cve/CVE-2026-16828.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-16828","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-16828"},"summary":{"title":"Power System Out-of-bounds Read","description":"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.","state":"PUBLISHED","assigner":"ibm","published_at":"2026-08-19 19:17:10","updated_at":"2026-08-21 17:16:29"},"problem_types":["CWE-125","CWE-125 CWE-125 Out-of-bounds Read"],"metrics":[{"version":"3.1","source":"psirt@us.ibm.com","type":"Secondary","score":"7.6","severity":"HIGH","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","baseScore":7.6,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"HIGH"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"7.6","severity":"HIGH","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","data":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","version":"3.1"}}],"references":[{"url":"https://www.ibm.com/support/pages/node/7283898","name":"https://www.ibm.com/support/pages/node/7283898","refsource":"psirt@us.ibm.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-16828","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-16828","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"IBM","product":"Power Systems Firmware","version":"affected FW1120.00","platforms":[]},{"source":"CNA","vendor":"IBM","product":"Power Systems Firmware","version":"affected FW1110.00 FW1110.30 semver","platforms":[]},{"source":"CNA","vendor":"IBM","product":"Power Systems Firmware","version":"affected FW1060.00 FW1060.80 semver","platforms":[]},{"source":"CNA","vendor":"IBM","product":"Power Systems Firmware","version":"affected FW950.00 FW950.H2 semver","platforms":[]}],"timeline":[],"solutions":[{"source":"CNA","title":"","value":"Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/","time":"","lang":"en"}],"workarounds":[{"source":"CNA","title":"","value":"Protect access to the FSP's network interface.","time":"","lang":"en"}],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"16828","cve":"CVE-2026-16828","epss":"0.001740000","percentile":"0.071510000","score_date":"2026-08-21","updated_at":"2026-08-22 00:12:48"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-16828","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-08-21T16:08:23.424581Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-08-21T16:14:39.868Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"cpes":["cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*","cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"],"product":"Power Systems Firmware","vendor":"IBM","versions":[{"status":"affected","version":"FW1120.00"},{"lessThanOrEqual":"FW1110.30","status":"affected","version":"FW1110.00","versionType":"semver"},{"lessThanOrEqual":"FW1060.80","status":"affected","version":"FW1060.00","versionType":"semver"},{"lessThanOrEqual":"FW950.H2","status":"affected","version":"FW950.00","versionType":"semver"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.</p>"}],"value":"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":7.6,"baseSeverity":"HIGH","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","description":"CWE-125 Out-of-bounds Read","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-19T18:59:57.704Z","orgId":"9a959283-ebb5-44b6-b705-dcc2bbced522","shortName":"ibm"},"references":[{"tags":["vendor-advisory","patch"],"url":"https://www.ibm.com/support/pages/node/7283898"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.</p><p>Power 11<br/>1) IBM Power System E1180 (9080-HEU)</p><p>Customers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.</p><p>Power 10<br/>1) IBM Power System E1080 (9080-HEX)</p><p>Customers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.</p><p>Power 9<br/>1) IBM Power System S922 (9009-22G)<br/>2) IBM Power System H922 (9223-22S)<br/>3) IBM Power System S914 (9009-41G)<br/>4) IBM Power System S924 (9009-42G)<br/>5) IBM Power System H924 (9223-42S)<br/>6) IBM Power System E950 (9040-MR9)<br/>7) IBM Power System E980 (9080-M9S)</p><p>The images mentioned above can be located at IBM Fix Central : <a href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\">https://www.ibm.com/support/fixcentral/</a></p>"}],"value":"Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central :  https://www.ibm.com/support/fixcentral/"}],"title":"Power System Out-of-bounds Read","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Protect access to the FSP's network interface.</p>"}],"value":"Protect access to the FSP's network interface."}]}},"cveMetadata":{"assignerOrgId":"9a959283-ebb5-44b6-b705-dcc2bbced522","assignerShortName":"ibm","cveId":"CVE-2026-16828","datePublished":"2026-08-19T18:43:41.541Z","dateReserved":"2026-07-24T02:25:57.107Z","dateUpdated":"2026-08-21T16:14:39.868Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-19 19:17:10","lastModifiedDate":"2026-08-21 17:16:29","problem_types":["CWE-125","CWE-125 CWE-125 Out-of-bounds Read"],"metrics":{"cvssMetricV31":[{"source":"psirt@us.ibm.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","baseScore":7.6,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":4.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-21T16:08:23.424581Z","id":"CVE-2026-16828","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"16828","Ordinal":"1","Title":"Power System Out-of-bounds Read","CVE":"CVE-2026-16828","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"16828","Ordinal":"1","NoteData":"IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.","Type":"Description","Title":"Power System Out-of-bounds Read"}]}}}