{"api_version":"1","generated_at":"2026-09-07T09:11:17+00:00","cve":"CVE-2026-16876","urls":{"html":"https://cve.report/CVE-2026-16876","api":"https://cve.report/api/cve/CVE-2026-16876.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-16876","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-16876"},"summary":{"title":"CVE-2026-16876","description":"An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet.","state":"PUBLISHED","assigner":"NEC","published_at":"2026-09-07 02:17:17","updated_at":"2026-09-07 02:17:17"},"problem_types":["CWE-306","CWE-306 CWE-306: Missing Authentication for Critical Function"],"metrics":[{"version":"4.0","source":"psirt-info@cyber.jp.nec.com","type":"Secondary","score":"9.3","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.3,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"9.3","severity":"CRITICAL","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","data":{"attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH"}}],"references":[{"url":"https://jpn.nec.com/security-info/secinfo/nv26-005_en.html","name":"https://jpn.nec.com/security-info/secinfo/nv26-005_en.html","refsource":"psirt-info@cyber.jp.nec.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-16876","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-16876","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"NEC Corporation","product":"UNIVERGE IX-R/IX-V","version":"affected All versions from Ver1.1 through Ver1.3, All versions from Ver1.4.21 through Ver1.4.28 and Ver1.5.23","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Kojiro Enokida of Sophos Ltd.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"cna":{"affected":[{"defaultStatus":"unknown","product":"UNIVERGE IX-R/IX-V","vendor":"NEC Corporation","versions":[{"status":"affected","version":"All versions from Ver1.1 through Ver1.3, All versions from Ver1.4.21 through Ver1.4.28 and Ver1.5.23"}]}],"credits":[{"lang":"en","type":"reporter","user":"00000000-0000-4000-9000-000000000000","value":"Kojiro Enokida of Sophos Ltd."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet."}],"value":"An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet."}],"metrics":[{"cvssV4_0":{"attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-306","description":"CWE-306: Missing Authentication for Critical Function","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-07T00:48:01.015Z","orgId":"f2760a35-e0d8-4637-ac4c-cc1a2de3e282","shortName":"NEC"},"references":[{"url":"https://jpn.nec.com/security-info/secinfo/nv26-005_en.html"}],"source":{"discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.2.0"}}},"cveMetadata":{"assignerOrgId":"f2760a35-e0d8-4637-ac4c-cc1a2de3e282","assignerShortName":"NEC","cveId":"CVE-2026-16876","datePublished":"2026-09-07T00:48:01.015Z","dateReserved":"2026-07-24T04:35:25.244Z","dateUpdated":"2026-09-07T00:48:01.015Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-07 02:17:17","lastModifiedDate":"2026-09-07 02:17:17","problem_types":["CWE-306","CWE-306 CWE-306: Missing Authentication for Critical Function"],"metrics":{"cvssMetricV40":[{"source":"psirt-info@cyber.jp.nec.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.3,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"16876","Ordinal":"1","Title":"CVE-2026-16876","CVE":"CVE-2026-16876","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"16876","Ordinal":"1","NoteData":"An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet.","Type":"Description","Title":"CVE-2026-16876"}]}}}