{"api_version":"1","generated_at":"2026-09-12T03:33:15+00:00","cve":"CVE-2026-17176","urls":{"html":"https://cve.report/CVE-2026-17176","api":"https://cve.report/api/cve/CVE-2026-17176.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-17176","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-17176"},"summary":{"title":"OS command injection Vulnerability in Deco BE11000","description":"An OS\ncommand injection vulnerability in the TDDP module of Deco BE11000 allows an\nadjacent network attacker to execute arbitrary commands with root privileges by\nsending a crafted UDP packet.\n\n\n\nSuccessful exploitation may lead to complete\ndevice compromise, including unauthorized command execution, modification of\ndevice settings, and loss of confidentiality, integrity, and availability","state":"PUBLISHED","assigner":"TPLink","published_at":"2026-09-11 00:17:26","updated_at":"2026-09-11 15:21:12"},"problem_types":["CWE-78","CWE-78 CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection')"],"metrics":[{"version":"4.0","source":"f23511db-6c3e-4e32-a477-6aa17d310630","type":"Secondary","score":"7.7","severity":"HIGH","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.7,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"7.7","severity":"HIGH","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"ADJACENT","baseScore":7.7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://www.tp-link.com/en/support/faq/5293/","name":"https://www.tp-link.com/en/support/faq/5293/","refsource":"f23511db-6c3e-4e32-a477-6aa17d310630","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.tp-link.com/us/support/download/deco-be11000/#Firmware","name":"https://www.tp-link.com/us/support/download/deco-be11000/#Firmware","refsource":"f23511db-6c3e-4e32-a477-6aa17d310630","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-17176","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-17176","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"TP-Link Systems Inc.","product":"Deco BE11000 V2","version":"affected 1.3.5 Build 26071712 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"17176","cve":"CVE-2026-17176","epss":"0.035930000","percentile":"0.887560000","score_date":"2026-09-11","updated_at":"2026-09-12 00:05:15"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-17176","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-09-11T14:32:22.502230Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-09-11T14:32:34.104Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","modules":["tddp"],"product":"Deco BE11000 V2","vendor":"TP-Link Systems Inc.","versions":[{"lessThan":"1.3.5 Build 26071712","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>An OS\ncommand injection vulnerability in the TDDP module of Deco BE11000 allows an\nadjacent network attacker to execute arbitrary commands with root privileges by\nsending a crafted UDP packet.</p>\n\nSuccessful exploitation may lead to complete\ndevice compromise, including unauthorized command execution, modification of\ndevice settings, and loss of confidentiality, integrity, and availability"}],"value":"An OS\ncommand injection vulnerability in the TDDP module of Deco BE11000 allows an\nadjacent network attacker to execute arbitrary commands with root privileges by\nsending a crafted UDP packet.\n\n\n\nSuccessful exploitation may lead to complete\ndevice compromise, including unauthorized command execution, modification of\ndevice settings, and loss of confidentiality, integrity, and availability"}],"impacts":[{"capecId":"CAPEC-248","descriptions":[{"lang":"en","value":"CAPEC-248 Command Injection"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"ADJACENT","baseScore":7.7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-09-10T23:14:33.974Z","orgId":"f23511db-6c3e-4e32-a477-6aa17d310630","shortName":"TPLink"},"references":[{"tags":["patch"],"url":"https://www.tp-link.com/us/support/download/deco-be11000/#Firmware"},{"url":"https://www.tp-link.com/en/support/faq/5293/"}],"source":{"discovery":"UNKNOWN"},"title":"OS command injection Vulnerability in Deco BE11000","x_generator":{"engine":"Vulnogram 1.0.4"}}},"cveMetadata":{"assignerOrgId":"f23511db-6c3e-4e32-a477-6aa17d310630","assignerShortName":"TPLink","cveId":"CVE-2026-17176","datePublished":"2026-09-10T23:14:33.974Z","dateReserved":"2026-07-24T18:24:49.819Z","dateUpdated":"2026-09-11T14:32:34.104Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-09-11 00:17:26","lastModifiedDate":"2026-09-11 15:21:12","problem_types":["CWE-78","CWE-78 CWE-78 Improper neutralization of special elements used in an OS command ('OS command injection')"],"metrics":{"cvssMetricV40":[{"source":"f23511db-6c3e-4e32-a477-6aa17d310630","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.7,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-09-11T14:32:22.502230Z","id":"CVE-2026-17176","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"17176","Ordinal":"1","Title":"OS command injection Vulnerability in Deco BE11000","CVE":"CVE-2026-17176","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"17176","Ordinal":"1","NoteData":"An OS\ncommand injection vulnerability in the TDDP module of Deco BE11000 allows an\nadjacent network attacker to execute arbitrary commands with root privileges by\nsending a crafted UDP packet.\n\n\n\nSuccessful exploitation may lead to complete\ndevice compromise, including unauthorized command execution, modification of\ndevice settings, and loss of confidentiality, integrity, and availability","Type":"Description","Title":"OS command injection Vulnerability in Deco BE11000"}]}}}