{"api_version":"1","generated_at":"2026-06-03T02:05:58+00:00","cve":"CVE-2026-25599","urls":{"html":"https://cve.report/CVE-2026-25599","api":"https://cve.report/api/cve/CVE-2026-25599.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-25599","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-25599"},"summary":{"title":"Missing authentication and clear‑text data transmission affecting Orca heat pumps","description":"Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an \nunencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an\n attacker to impersonate a legitimate device and inject malicious \npayloads. This enables the insertion of harmful code directly\n into the Orca user portal, potentially compromising user accounts, \nexposing sensitive information, and allowing further unauthorized \nactions within the portal.","state":"PUBLISHED","assigner":"ENISA","published_at":"2026-06-01 11:16:24","updated_at":"2026-06-01 18:02:29"},"problem_types":["CWE-79","CWE-306","CWE-319","CWE-79 CWE-79 Improper neutralization of input during web page generation ('cross-site scripting')","CWE-306 CWE-306 Missing authentication for critical function","CWE-319 CWE-319 Cleartext transmission of sensitive information"],"metrics":[{"version":"3.1","source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","score":"6.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","baseScore":6.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"}},{"version":"3.1","source":"CNA","type":"CVSS","score":"6.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":6.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","version":"3.1"}}],"references":[{"url":"https://www.cert.si/en/cve-2026-25599/","name":"https://www.cert.si/en/cve-2026-25599/","refsource":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-25599","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-25599","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Orca Energy","product":"Orca heat pump","version":"affected 2.1.0 semver","platforms":[]},{"source":"CNA","vendor":"Orca Energy","product":"Orca user portal","version":"affected 1.19 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"CNA","value":"Tom Kern, NIL d.o.o.","lang":"en"}],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2026","cve_id":"25599","cve":"CVE-2026-25599","epss":"0.000180000","percentile":"0.049540000","score_date":"2026-06-02","updated_at":"2026-06-03 00:08:15"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-25599","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-06-01T13:01:12.777564Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-06-01T13:01:21.955Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Orca heat pump","vendor":"Orca Energy","versions":[{"lessThan":"2.1.0","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Orca user portal","vendor":"Orca Energy","versions":[{"lessThan":"1.19","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Tom Kern, NIL d.o.o."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface.&nbsp;Older Orca heat pump devices communicating with the Orca server over an \nunencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an\n attacker to impersonate a legitimate device and inject malicious \npayloads. This enables the insertion of harmful code directly\n into the Orca user portal, potentially compromising user accounts, \nexposing sensitive information, and allowing further unauthorized \nactions within the portal."}],"value":"Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an \nunencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an\n attacker to impersonate a legitimate device and inject malicious \npayloads. This enables the insertion of harmful code directly\n into the Orca user portal, potentially compromising user accounts, \nexposing sensitive information, and allowing further unauthorized \nactions within the portal."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":6.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Improper neutralization of input during web page generation ('cross-site scripting')","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-306","description":"CWE-306 Missing authentication for critical function","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-319","description":"CWE-319 Cleartext transmission of sensitive information","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-06-01T09:17:51.060Z","orgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","shortName":"ENISA"},"references":[{"url":"https://www.cert.si/en/cve-2026-25599/"}],"source":{"discovery":"UNKNOWN"},"tags":["unsupported-when-assigned"],"title":"Missing authentication and clear‑text data transmission affecting Orca heat pumps","x_generator":{"engine":"Vulnogram 1.0.2"}}},"cveMetadata":{"assignerOrgId":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","assignerShortName":"ENISA","cveId":"CVE-2026-25599","datePublished":"2026-06-01T09:17:51.060Z","dateReserved":"2026-02-03T07:24:49.547Z","dateUpdated":"2026-06-01T13:01:21.955Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-06-01 11:16:24","lastModifiedDate":"2026-06-01 18:02:29","problem_types":["CWE-79","CWE-306","CWE-319","CWE-79 CWE-79 Improper neutralization of input during web page generation ('cross-site scripting')","CWE-306 CWE-306 Missing authentication for critical function","CWE-319 CWE-319 Cleartext transmission of sensitive information"],"metrics":{"cvssMetricV31":[{"source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","baseScore":6.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":3.4}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"25599","Ordinal":"1","Title":"Missing authentication and clear‑text data transmission affectin","CVE":"CVE-2026-25599","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"25599","Ordinal":"1","NoteData":"Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an \nunencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an\n attacker to impersonate a legitimate device and inject malicious \npayloads. This enables the insertion of harmful code directly\n into the Orca user portal, potentially compromising user accounts, \nexposing sensitive information, and allowing further unauthorized \nactions within the portal.","Type":"Description","Title":"Missing authentication and clear‑text data transmission affectin"}]}}}