{"api_version":"1","generated_at":"2026-08-22T08:12:21+00:00","cve":"CVE-2026-27875","urls":{"html":"https://cve.report/CVE-2026-27875","api":"https://cve.report/api/cve/CVE-2026-27875.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-27875","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-27875"},"summary":{"title":"Simplex Incident Manager Clear Test","description":"Cleartext Storage of Sensitive Information in Memory vulnerability in Johnson Controls Simplex Incident Manager / Autocall Fire Administrator may allow an attcker to Retrieve Embedded Sensitive Data.\n\nThis issue affects Simplex Incident Manager / Autocall Fire Administrator: before 2.01.05.","state":"PUBLISHED","assigner":"jci","published_at":"2026-08-21 18:16:47","updated_at":"2026-08-21 21:16:56"},"problem_types":["CWE-316","CWE-316 CWE-316: Cleartext Storage of Sensitive Information in Memory"],"metrics":[{"version":"4.0","source":"productsecurity@jci.com","type":"Secondary","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","data":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","attackRequirements":"PRESENT","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"HIGH","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}},{"version":"4.0","source":"CNA","type":"CVSS","score":"6.9","severity":"MEDIUM","vector":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:N/SA:N","data":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"HIGH","attackRequirements":"PRESENT","attackVector":"LOCAL","baseScore":6.9,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"}}],"references":[{"url":"https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories","name":"https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories","refsource":"productsecurity@jci.com","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-27875","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-27875","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Johnson Controls","product":"Simplex Incident Manager / Autocall Fire Administrator","version":"affected 2.01.05 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"other":{"content":{"id":"CVE-2026-27875","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-08-21T19:44:01.455351Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-08-21T20:08:37.055Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"defaultStatus":"unaffected","product":"Simplex Incident Manager / Autocall Fire Administrator","vendor":"Johnson Controls","versions":[{"lessThan":"2.01.05","status":"affected","version":"0","versionType":"custom"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:johnson_controls:simplex_incident_manager_autocall_fire_administrator:*:*:*:*:*:*:*:*","versionEndExcluding":"2.01.05","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"&nbsp;Cleartext Storage of Sensitive Information in Memory vulnerability in Johnson Controls Simplex Incident Manager / Autocall Fire Administrator may allow an attcker to Retrieve Embedded Sensitive Data.<p>This issue affects Simplex Incident Manager / Autocall Fire Administrator: before 2.01.05.</p>"}],"value":"Cleartext Storage of Sensitive Information in Memory vulnerability in Johnson Controls Simplex Incident Manager / Autocall Fire Administrator may allow an attcker to Retrieve Embedded Sensitive Data.\n\nThis issue affects Simplex Incident Manager / Autocall Fire Administrator: before 2.01.05."}],"impacts":[{"descriptions":[{"lang":"en","value":"CAPEC‑37: Retrieve Embedded Sensitive Data"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"HIGH","attackRequirements":"PRESENT","attackVector":"LOCAL","baseScore":6.9,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"HIGH","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-316","description":"CWE-316: Cleartext Storage of Sensitive Information in Memory","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-08-21T17:52:49.383Z","orgId":"7281d04a-a537-43df-bfb4-fa4110af9d01","shortName":"jci"},"references":[{"url":"https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"}],"source":{"discovery":"UNKNOWN"},"title":"Simplex Incident Manager Clear Test","x_generator":{"engine":"Vulnogram 1.0.4"}}},"cveMetadata":{"assignerOrgId":"7281d04a-a537-43df-bfb4-fa4110af9d01","assignerShortName":"jci","cveId":"CVE-2026-27875","datePublished":"2026-08-21T17:52:49.383Z","dateReserved":"2026-02-24T11:29:18.530Z","dateUpdated":"2026-08-21T20:08:37.055Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-08-21 18:16:47","lastModifiedDate":"2026-08-21 21:16:56","problem_types":["CWE-316","CWE-316 CWE-316: Cleartext Storage of Sensitive Information in Memory"],"metrics":{"cvssMetricV40":[{"source":"productsecurity@jci.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","attackRequirements":"PRESENT","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"HIGH","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-21T19:44:01.455351Z","id":"CVE-2026-27875","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"configurations":[]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"27875","Ordinal":"1","Title":"Simplex Incident Manager Clear Test","CVE":"CVE-2026-27875","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"27875","Ordinal":"1","NoteData":"Cleartext Storage of Sensitive Information in Memory vulnerability in Johnson Controls Simplex Incident Manager / Autocall Fire Administrator may allow an attcker to Retrieve Embedded Sensitive Data.\n\nThis issue affects Simplex Incident Manager / Autocall Fire Administrator: before 2.01.05.","Type":"Description","Title":"Simplex Incident Manager Clear Test"}]}}}