{"api_version":"1","generated_at":"2026-05-13T07:41:02+00:00","cve":"CVE-2026-31255","urls":{"html":"https://cve.report/CVE-2026-31255","api":"https://cve.report/api/cve/CVE-2026-31255.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2026-31255","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-31255"},"summary":{"title":"CVE-2026-31255","description":"A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands.","state":"PUBLISHED","assigner":"mitre","published_at":"2026-04-27 19:16:47","updated_at":"2026-04-28 15:16:28"},"problem_types":["CWE-77","n/a","CWE-77 CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.1","source":"ADP","type":"DECLARED","score":"5.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.4,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"5.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"}}],"references":[{"url":"https://github.com/izxnfirh8148/CVE_REQUESTS_references/blob/main/Tenda_AC18/Tenda_AC18_3th/README.md","name":"https://github.com/izxnfirh8148/CVE_REQUESTS_references/blob/main/Tenda_AC18/Tenda_AC18_3th/README.md","refsource":"134c704f-9b21-4f2e-91b3-4a467353bcc0","tags":["Exploit","Third Party Advisory"],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-31255","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-31255","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2026","cve_id":"31255","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tenda","cpe5":"ac18","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2026","cve_id":"31255","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tenda","cpe5":"ac18_firmware","cpe6":"15.03.05.05","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.4,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","version":"3.1"}},{"other":{"content":{"id":"CVE-2026-31255","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-04-28T15:05:55.581133Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-77","description":"CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-04-28T15:06:36.415Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"references":[{"tags":["exploit"],"url":"https://github.com/izxnfirh8148/CVE_REQUESTS_references/blob/main/Tenda_AC18/Tenda_AC18_3th/README.md"}],"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2026-04-27T18:29:20.168Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"url":"https://github.com/izxnfirh8148/CVE_REQUESTS_references/blob/main/Tenda_AC18/Tenda_AC18_3th/README.md"}]}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2026-31255","datePublished":"2026-04-27T00:00:00.000Z","dateReserved":"2026-03-09T00:00:00.000Z","dateUpdated":"2026-04-28T15:06:36.415Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2026-04-27 19:16:47","lastModifiedDate":"2026-04-28 15:16:28","problem_types":["CWE-77","n/a","CWE-77 CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.5}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*","matchCriteriaId":"4D5CB727-FC6B-4212-A61E-2888A0DADFB0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*","matchCriteriaId":"CF9F8AF9-F921-4348-922B-EE5E6037E7AC"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2026","CveId":"31255","Ordinal":"1","Title":"CVE-2026-31255","CVE":"CVE-2026-31255","Year":"2026"},"notes":[{"CveYear":"2026","CveId":"31255","Ordinal":"1","NoteData":"A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands.","Type":"Description","Title":"CVE-2026-31255"}]}}}